Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -250 - 250 Pa
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -250 - 250 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -250 - 250 Pa

MOQ : 5 Pieces

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -250 - 250 Pa Specification

  • Grade
  • Industrial Grade
  • Thread
  • 1/8 NPT Female
  • Outer Size
  • 115 x 85 x 35 mm (approx)
  • Seal Material
  • Silicone
  • Sensor Type
  • Differential Pressure Sensor
  • Display
  • Digital LCD Display
  • Material
  • ABS Plastic
  • Processing Type
  • Electronic
  • Mount Type
  • Wall Mount
  • Scale Range
  • -250 to 250 Pa
  • Accuracy
  • 1% of FS
  • Accessories
  • Mounting Screws, Instruction Manual
  • Output Signal
  • 4-20 mA (2-wire), 0-10 V
  • Power Supply
  • 24V DC (15-36V DC permissible)
  • Overpressure Limit
  • 10 kPa
  • Temperature Range
  • -10C to 50C
  • Weight
  • Approx 150 g
  • Model
  • DPT1-R8
  • Zero/Span Adjustment
  • Pushbutton
  • Response Time
  • < 1 s
  • Compliance
  • CE Marked
  • Pressure Connection
  • 2 x 6 mm hose nipples
  • Application
  • HVAC, Clean Rooms, Filter Monitoring, Fan Control
  • Protection Class
  • IP54
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -250 - 250 Pa Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • FOB Port
  • delhi
  • Payment Terms
  • Cash Against Delivery (CAD), Cash Advance (CA), Cash on Delivery (COD), Cash in Advance (CID)
  • Supply Ability
  • 4 Pieces Per Day
  • Delivery Time
  • 4-6 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Middle East, Asia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -250 - 250 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -250 - 250 Pa

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Key Features for Industrial Use

Equipped with a measurement range of -250 to 250 Pa and an impressive overpressure limit of 10 kPa, the Series DPT1-R8 stands out in demanding applications. Users benefit from a highly accurate sensor (1% FS), fast response time, and straightforward configuration with pushbutton zero and span adjustment. ABS housing and IP54 protection assure longevity in both industrial and commercial environments.


Versatile Applications and Compatibility

This transmitter is adept at monitoring differential pressure in HVAC operations, cleanrooms, and across industrial processes requiring the measurement of steam, oil, or gas. Its dual output signals (4-20 mA and 0-10 V) and easy wall-mount design make it ideal for integration into various control and monitoring systems. The inclusion of standard 1/8 NPT threads and 6 mm hose nipples ensures broad compatibility.

FAQ's of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -250 - 250 Pa:


Q: How do I install the Sensocon DPT1-R8 Differential Pressure Transmitter?

A: The transmitter is designed for straightforward wall mounting. Included accessories, such as mounting screws and an instruction manual, guide you through attaching the ABS housing to your desired location. Connect the 6 mm hoses to the hose nipples, and use 1/8 NPT female threads where applicable. Ensure power is supplied within the 15-36V DC range.

Q: What settings can I adjust on the DPT1-R8 series transmitter?

A: You can conveniently adjust the zero and span settings using the onboard pushbutton. This allows precise calibration of the measurement range to accommodate specific application requirements, ensuring optimal accuracy and performance.

Q: When should I use this transmitter in my facility?

A: The Series DPT1-R8 is ideal for continuous monitoring of low differential pressure, notably in HVAC systems, clean rooms, filter status checking, and fan control applications. Use it when reliable, linear pressure measurement is essential for system safety, energy efficiency, or regulatory compliance.

Q: Where is the best location to mount the DPT1-R8 transmitter?

A: For best results, mount the transmitter in a location that is free from excessive vibration, direct heat, or moisture exposure. It is typically installed close to the area where pressure measurements are critical, such as across air filters, fans, or within cleanroom walls.

Q: What processes benefit most from this pressure transmitter?

A: Industrial processes requiring precise pressure monitoring-such as HVAC control, clean room pressure balancing, filter monitoring, and optimized fan operation-benefit greatly. The DPT1-R8 can also be used to measure the differential pressure of steam, oil, or gas, ensuring operational integrity.

Q: How does the digital LCD display aid in transmitter operation?

A: The integrated LCD display provides real-time, clear readings of differential pressure, allowing quick visual checks and troubleshooting. This helps technicians monitor system health without relying solely on remote data interfaces.

Q: What advantages does the DPT1-R8 offer over other differential pressure transmitters?

A: Its combination of fast response time, high accuracy, dual output signals, robust industrial-grade construction, and easy calibration offers users enhanced reliability, greater flexibility in integration, and a prolonged service life even in challenging environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Differential Pressure Transmitter-Sensocon USA Category

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 0.25  mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 0.25 mbar

Minimum Order Quantity : 5 Pieces

Display : Digital

Material : Other, ABS Plastic housing

Accuracy : 1% of FS

Outer Size : See drawing/consult datasheet

Seal Material : Nitrile/EPDM

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 1.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 1.25 mbar

Minimum Order Quantity : 5 Pieces

Display : No Onboard Display

Material : Other, ABS Plastic, Electronic Components

Accuracy : 1% of Span

Outer Size : Approx. 90 x 78 x 36 mm (L x W x H)

Seal Material : Silicone

Sensocon USA Series DPT1-R8 - Range -0.5 - .05 in WC

Sensocon USA Series DPT1-R8 - Range -0.5 - .05 in WC

Minimum Order Quantity : 5 Pieces

Display : LCD Digital

Material : Other, ABS Plastic Housing

Accuracy : 1% of full scale

Outer Size : 110 mm x 83 mm x 24 mm

Seal Material : Silicone

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.7 - 12.7 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.7 - 12.7 mmWC

Minimum Order Quantity : 5 Pieces

Display : Digital Display

Material : Other, ABS Plastic Housing

Accuracy : 1% of FS

Outer Size : 110 x 80 x 37 mm (L x W x H)

Seal Material : Silicone