Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -1.25 - 1.25 mbar
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -1.25 - 1.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -1.25 - 1.25 mbar

MOQ : 5 Pieces

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -1.25 - 1.25 mbar Specification

  • Grade
  • Industrial
  • Sensor Type
  • Differential Pressure Transmitter
  • Thread
  • G1/8 (Female)
  • Display
  • Digital (with LED indicator)
  • Seal Material
  • NBR (Nitrile Rubber)
  • Outer Size
  • Approximately 80 mm x 80 mm x 35 mm
  • Material
  • ABS Plastic housing
  • Dial Material
  • Not Applicable (Digital Display)
  • Pointer Material
  • Not Applicable (Digital Display)
  • Processing Type
  • Electronic
  • Diameter
  • 80 mm (approximate)
  • Mount Type
  • Surface/Wall Mount
  • Scale Range
  • -1.25 - +1.25 mbar
  • Accuracy
  • 1% of Full Scale
  • Accessories
  • Mounting screws, instruction manual, calibration certificate
  • Zero and Span Adjustment
  • Push button on device
  • Response Time
  • <100 ms
  • Protection Class
  • IP54
  • Output Signal
  • 4-20 mA (2-wire system)
  • Media Compatibility
  • Dry, clean air and non-corrosive gases
  • Electrical Connection
  • Screw terminals
  • Overpressure Limit
  • 50 mbar
  • Power Supply
  • 24V DC (18-30V) / 24V AC (optional)
  • Weight
  • Approx. 110 g
  • Temperature Range
  • Operating: 0C to +50C
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -1.25 - 1.25 mbar Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • FOB Port
  • delhi
  • Payment Terms
  • Cash in Advance (CID), Cash Against Delivery (CAD), Cash Advance (CA), Cash on Delivery (COD)
  • Supply Ability
  • 4 Pieces Per Day
  • Delivery Time
  • 4-6 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Asia, Middle East
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -1.25 - 1.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -1.25 - 1.25 mbar

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Precise Differential Pressure Measurement

The DPT1-R8 delivers accurate differential pressure monitoring, covering ranges from -1.25 to +1.25 mbar. Its industrial-grade construction and high-precision electronics ensure reliable performance in demanding environments. Ideal for applications requiring sensitive detection of small pressure changes, this transmitter comes with a calibration certificate, guaranteeing conformity to accuracy specifications.


Robust Construction and Versatile Installation

Featuring an ABS plastic body with industrial-grade coating, the DPT1-R8 is designed to resist corrosion while maintaining a lightweight profile. Its IP54 protection class shields it from dust and splashes. The surface or wall-mount design enables quick, secure installation using supplied mounting screws. Electrical and process connections are straightforward via screw terminals and G1/8 (female) threads.


User-friendly Operation and Maintenance

This transmitter incorporates a simple push-button interface for easy zero and span adjustments, complemented by a bright digital LED indicator for real-time readings. Maintenance is straightforward due to clear instructions and accessible terminals, making the DPT1-R8 suitable for both engineers and technicians working in various industrial settings.

FAQ's of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -1.25 - 1.25 mbar:


Q: How do I install the Sensocon DPT1-R8 differential pressure transmitter?

A: Installation involves mounting the device to a flat surface or wall using the included screws. Electrical connections are made via the accessible screw terminals, and the pressure ports accept G1/8 (female) threads. Ensure the device is connected to a 24V DC power supply, or 24V AC if specified.

Q: What types of media can be measured with this transmitter?

A: The DPT1-R8 is designed for dry, clean air and non-corrosive gases, as well as for monitoring differential pressure in steam, oil, and gas applications within its specified range. It is not compatible with aggressive or corrosive media.

Q: When should I perform zero and span adjustments, and how is it done?

A: Zero and span calibration should be performed during initial installation, after maintenance, or if drift in readings is observed. Adjustments are easy using the push buttons on the device, following the steps provided in the instruction manual.

Q: Where can the transmitter be used considering its protection class and temperature range?

A: With an IP54 protection class, the DPT1-R8 is suitable for installation in environments where it may be exposed to dust and splashes but should not be fully submerged. Operating temperatures should remain between 0C and +50C.

Q: What is the response time and accuracy of the DPT1-R8?

A: The transmitter provides a rapid response time of less than 100 ms, with an accuracy of 1% of full scale, ensuring timely and precise pressure monitoring.

Q: How does the transmitter communicate measured values?

A: Measured differential pressure is output as a 4-20 mA analog signal in a two-wire configuration, and the current reading is displayed digitally via the integrated LED indicator.

Q: What are the main benefits of using the Series DPT1-R8 in industrial processes?

A: Key benefits include precise low-range pressure measurement, user-friendly digital calibration, robust construction suitable for industrial settings, quick response, and clear digital readouts, all supported with calibration certification and straightforward installation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Differential Pressure Transmitter-Sensocon USA Category

Sensocon USA Series DPT1-R8 - Range 0 - 0.25 in WC

Sensocon USA Series DPT1-R8 - Range 0 - 0.25 in WC

Minimum Order Quantity : 5 Pieces

Seal Material : Integrated EPDM Seals

Outer Size : H 120 mm x W 90 mm x D 36 mm (approx.)

Display : Digital LCD Display

Scale Range : 0 0.25 in WC

Thread : N/A (Pressure ports are pushon type for tubing connection)

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -127 - 127 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -127 - 127 mmWC

Minimum Order Quantity : 5 Pieces

Seal Material : EPDM

Outer Size : 110 x 87 x 32 mm

Display : LCD Digital Display

Scale Range : 127 to +127 mmWC

Thread : 1/8 NPT Female

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -10.0 - 10.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -10.0 - 10.0 inWC

Minimum Order Quantity : 5 Pieces

Seal Material : Silicone

Outer Size : 117 mm x 82 mm x 40 mm (approx.)

Display : LCD Digital Display

Scale Range : 10.0 to 10.0 inWC

Thread : 1/8 NPT Female Pressure Ports

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar

Minimum Order Quantity : 5 Pieces

Seal Material : Silicone

Outer Size : Approx. 112 x 102 x 48 mm

Display : LED Digital Display

Scale Range : 12.5 to 12.5 mbar

Thread : 1/8 NPT