About Huba Control Differential Pressure Transmitter Model 692.914007141 Range : 0-1.6 BAR
Huba Control Differential Pressure Transmitter Model 692.914007141 Range : 0-1.6 BAR
- Brand : Huba Control
- Model : 692.914007141
- Range : 0...+1.6 BAR
- Type : 692 0...+1.6 BAR
- Current Out : 4-20mA
- Voltage : 11-33V DC
- MAX : P1-P2 12BAR
- MAX : P2-P1 12BAR
- Made In Switzerland
Huba Control Differential Pressure Transmitter Product InformationDifferential Pressure Transmitter 692
The Pressure Transmitters of Type 692 Feature The Unique And Proven Ceramic Technology. Depending On The Application, Various Pressure Connections And Electrical Connections With Standardized Output Signals Are Available. Due To The Wide Variety Of Options,The Transmitters 692 Are Suitable For All Types Of Industrial Applications.
- Very Low Temperature Sensitivity
- High Temperature Resistance
- No Mechanical Creep
- Individual Applications Through Modular System And Different Material Choices
Technical DataProduct Feature
- Pressure Measuring Range : 0 ... 25 Bar (Relative And Difference)
- Response Time : <5 ms
- Load Change : <50 Hz
- Sensor Weight : 430 g
Field Of Application
- Media : Process Medium; Gas
- Medium Temperature : -15 ... 85 AC
- Permissible Overload On One Side : See Variant Plan
- System Pressure : 12; 25; 50 Bar
- Bursting Pressure : 1.5 x System Pressure
Ambient Condition
- Ambient Temperature : -15 ... 85 AC
- Storage Temperature : -40 ... 85 AC
Material
- Housing : Stainless Steel 1.4305 (AISI 303); PVDF
- Pressure Connection With Media Contact : Stainless Steel 1.4305 (AISI 303); PVDF; CuZn Vni
- Measuring Element With Media Contact : Ceramic Al2O3 (96 %)
- Sealing Material With Media Contact : FPM; EDPM; NBR; MVQ; CR
Electrical Data
- Current Consumption : <20 mA
- Inverse-Polarity Protection : Short-Circuit And Reverse Polarity Protected. Each Connection Against Each Other With Max. Supply Voltage.
Installation Guide
- Installation Orientation : any
- Assembly : Mounting Bracket
Approval
EMC Compatibility : CE-Compliant In Accordance With EN 61326-2-3
Applications
- REFRIGERATION SYSTEMS
- CPU
- WATER PUMPS
- ULTRAFILTRATION SYSTEM
Accessories
- Mounting Bracket
- Socket Outlet DIN EN 175301-803-A : With Seal; IP 65, When Mounted And Screwed.
- Socket Outlet DIN EN 60130-9 : IP 65, When Mounted And Screwed.
- Calibration Certificate
- WhatsApp No.9871014210,WhatsApp No.9811065204,WhatsApp No.8376899729,WhatsApp No.8368888047,WhatsApp No.9268631221,

Versatile and Durable DesignThis differential pressure transmitter is built to withstand demanding industrial environments. Its robust stainless steel construction and multiple finishing options ensure longevity and corrosion resistance, making it a reliable choice even in harsh settings. With a compact weight and size, it offers easy installation and versatile mounting capabilities.
Precision for Critical ProcessesFeaturing a high accuracy of 0.5%, the Model 692.914007141 provides reliable pressure readings essential for quality control in industries like sugar, steel, paper, and cement. Its 0-1.6 BAR scale range allows it to precisely monitor pressure in processes involving steam, oil, or gas, facilitating optimal operational efficiency.
FAQ's of Huba Control Differential Pressure Transmitter Model 692.914007141 Range : 0-1.6 BAR:
Q: How is the Huba Control Model 692.914007141 typically used in industrial applications?
A: This transmitter is commonly used to measure differential pressure in steam, oil, and gas systems within industries such as sugar production, steel manufacturing, paper mills, and cement plants. Its high accuracy and durable build make it a trusted solution for process monitoring and automation.
Q: What installation process should be followed for this differential pressure transmitter?
A: To install, securely mount the unit on a panel using the designated fittings and connect it using the 1/4 inch NPT threads. Ensure proper sealing and orientation as per the manufacturer's guidelines to achieve accurate readings. Professional installation by qualified personnel is recommended.
Q: When should I consider recalibrating this transmitter for continued accuracy?
A: It is advisable to recalibrate the device annually, or more frequently if it is exposed to variable process conditions, harsh chemicals, or if regulatory standards in your industry demand it. Routine calibration helps maintain its accuracy of 0.5%.
Q: Where does this model offer the most benefit in a processing plant?
A: The transmitter is especially beneficial in locations where continuous and reliable monitoring of differential pressure is crucial, such as in filtration systems, flow measurement points, or safety-critical steam and oil pipelines across industries like sugar, steel, paper, and cement.
Q: What are the advantages of the different finishing options available?
A: The antique, polished, galvanized, and matte finishing choices offer varying degrees of resistance to corrosion and wear, allowing you to select the most suitable option based on your facility's environment-enhancing longevity and maintaining the transmitter's performance.
Q: How does this pressure transmitter contribute to process efficiency and safety?
A: By delivering precise differential pressure measurements, the transmitter enables prompt detection of pressure deviations, improving process control and preventing equipment damage or safety incidents, thereby optimizing plant efficiency and safety protocols.