Back to top
Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 5000 Pa
Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 5000 Pa

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 5000 Pa

MOQ : 5 Pieces

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 5000 Pa Specification

  • Thread
  • Push-in fittings (1/8 NPT optional)
  • Outer Size
  • 115 mm x 90 mm x 55 mm (approx.)
  • Display
  • Digital LCD Display
  • Grade
  • Industrial
  • Seal Material
  • Silicone
  • Sensor Type
  • Differential Pressure Sensor
  • Material
  • ABS Plastic Housing, Silicon Sensor
  • Processing Type
  • Electronic
  • Diameter
  • N/A (Rectangular body)
  • Mount Type
  • Wall/Cabinet Mounting
  • Scale Range
  • 0 - 5000 Pa
  • Accuracy
  • 1.0% of Full Scale
  • Accessories
  • Mounting Screws, Installation Manual
  • Zero & Span Adjustment
  • Via push-button
  • Output Signal
  • 4-20 mA, Two-wire or 0-10 V DC selectable
  • IP Rating
  • IP65 (front)
  • Media Compatibility
  • Air and non-aggressive gases
  • Over Pressure Limit
  • 10 kPa (twice full scale)
  • Operating Temperature
  • -10C to +50C
  • Electrical Connections
  • Screw terminal block, cable gland entry
  • Power Supply
  • 24 V DC (12-36 V DC range)
  • Weight
  • Approx. 180 grams
  • Response Time
  • <100 ms
 

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 5000 Pa Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • FOB Port
  • delhi
  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash Advance (CA), Cash in Advance (CID)
  • Supply Ability
  • 4 Pieces Per Day
  • Delivery Time
  • 4-6 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Asia, Middle East
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 5000 Pa

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 5000 Pa 

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Versatile Output and Power Options

The DPT30-R8 offers selectable analog outputs (4-20 mA two-wire or 0-10 V DC), allowing seamless integration into various control and monitoring systems. Its flexible supply voltage (12-36 V DC) facilitates compatibility with most industrial power sources, making it adaptable for different application requirements.


Rugged Design for Demanding Environments

Engineered with an ABS plastic enclosure and a front-panel IP65 rating, this transmitter withstands dust and moisture, making it ideal for demanding industrial settings. Its zero and span adjustments via push-button streamline onsite calibration, and the clear LCD display provides immediate reading visibility.


Quick Installation and Wide Applications

Supplied with mounting screws and a comprehensive installation manual, the DPT30-R8 supports wall or cabinet mounting for quick setup. Compatible with push-in fittings (1/8 NPT optional), it aptly serves HVAC, process control, and filtration systems for measuring steam, oil, or gas pressures.

FAQ's of Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 5000 Pa:


Q: How can I switch between output signals on the Sensocon DPT30-R8 differential pressure transmitter?

A: You can select between a 4-20 mA two-wire output or a 0-10 V DC output using a built-in selector. Refer to the installation manual for step-by-step instructions on configuring the output to match your system requirements.

Q: What is the recommended procedure for installing and mounting the transmitter?

A: Mount the transmitter on a wall or cabinet using the provided mounting screws. Electrical connections are made via the screw terminal block and cable gland entry. Follow the installation manual for wiring and ideal placement to ensure accurate pressure readings.

Q: When should I perform zero and span adjustments, and how are they conducted?

A: Zero and span adjustments are necessary after installation or maintenance to ensure accuracy. Use the push-buttons located on the unit's front panel to execute these adjustments as instructed in the manual. This process takes only a few minutes.

Q: What media is compatible with the DPT30-R8, and what substances should be avoided?

A: The transmitter is designed for measuring differential pressure in air and non-aggressive gases. Contact with aggressive chemicals or liquids should be avoided to prevent sensor damage and maintain accurate performance.

Q: Where is the DPT30-R8 best suited for use, and what are its typical applications?

A: This model is ideal for industrial environments such as HVAC systems, process control, filtration monitoring, and cleanrooms. Its robust construction and high accuracy make it suitable for measuring steam, oil, and gas pressure differentials in various facility settings.

Q: What is the process for connecting the transmitter electrically?

A: Electrical connection is straightforward using the included screw terminal block and cable gland entry. Ensure the power supply is within the 12-36 V DC range before connecting the output to your control system. Detailed wiring diagrams can be found in the installation manual.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Differential Pressure Transmitter-Sensocon USA Category

Sensocon USA Series DPT1-R8 - Range -25 - 25 Pa

Sensocon USA Series DPT1-R8 - Range -25 - 25 Pa

Minimum Order Quantity : 5 Pieces

Accessories : Mounting screws, installation manual

Scale Range : 25 to 25 Pa

Thread : Pushon tubing connection

Mount Type : Other, Wall/Surface Mount

Outer Size : 110 x 89 x 34 mm

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 5.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 5.0 inWC

Minimum Order Quantity : 5 Pieces

Accessories : Mounting Screws, Manual

Scale Range : 0 5.0 inWC

Thread : 1/8 NPT

Mount Type : Other, Wall or Duct Mounted

Outer Size : 92 mm x 92 mm x 41 mm (L x W x D)

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0-25.4 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0-25.4 mmWC

Minimum Order Quantity : 5 Pieces

Accessories : Mounting screws, User manual

Scale Range : 025.4 mmWC

Thread : 1/8 NPT

Mount Type : Other, Panel/Surface Mount

Outer Size : Body: 99 mm x 61 mm x 36 mm (approx.)

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 380 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 380 mmWC

Minimum Order Quantity : 5 Pieces

Accessories : Mounting Bracket, Instruction Manual

Scale Range : 0 380 mmWC

Thread : 1/8 NPT Female

Mount Type : Other, Panel/Wall Mount

Outer Size : 110 mm x 85 mm x 55 mm (Approx.)