Back to top
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -2.5 - 2.5 mbar
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -2.5 - 2.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -2.5 - 2.5 mbar

MOQ : 5 Pieces

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -2.5 - 2.5 mbar Specification

  • Thread
  • 1/8 NPT Female
  • Seal Material
  • Silicone
  • Grade
  • Industrial Grade
  • Outer Size
  • 110 x 90 x 35 mm (approx)
  • Display
  • Digital LCD
  • Sensor Type
  • Differential Pressure Sensor
  • Material
  • ABS Plastic housing
  • Processing Type
  • Electronic
  • Mount Type
  • Wall / Surface Mount
  • Scale Range
  • -2.5 to 2.5 mbar
  • Accuracy
  • 1% of F.S.
  • Accessories
  • Wall mounting kit, instruction manual
  • Model
  • DPT1-R8
  • Temperature Range
  • -10C to +50C
  • Power Supply
  • 24 VDC
  • Output Signal
  • 4-20 mA, 2-wire
  • Overpressure Limit
  • 50 mbar
  • Response Time
  • < 1 s
  • Protection Class
  • IP54
  • Zero & Span Adjustment
  • Push-button
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -2.5 - 2.5 mbar Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • FOB Port
  • delhi
  • Payment Terms
  • Cash on Delivery (COD), Cash Advance (CA), Cash Against Delivery (CAD), Cash in Advance (CID)
  • Supply Ability
  • 4 Pieces Per Day
  • Delivery Time
  • 4-6 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Middle East, Asia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -2.5 - 2.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -2.5 - 2.5 mbar

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Precision in Low-Pressure Measurement

The DPT1-R8 transmitter offers a high degree of accuracy (1% of full scale), making it suitable for critical differential pressure applications involving steam, oil, or gas. The device's electronic processing and fast response enable real-time system monitoring and control.


Robust Industrial Design

Built with an ABS plastic enclosure and silicone seals, the transmitter withstands harsh industrial environments. IP54 protection guards against dust and splashes, while the matte finish and compact size (110 x 90 x 35 mm) provide a practical and durable solution for on-site installations.


Easy Installation and Operation

Supplied with a wall mounting kit and a straightforward instruction manual, the DPT1-R8 ensures hassle-free setup. Push-button adjustments for zero and span allow for quick calibration, reducing downtime and maintenance efforts. The digital LCD display guarantees clear readability.

FAQ's of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -2.5 - 2.5 mbar:


Q: How do I install the Sensocon DPT1-R8 Differential Pressure Transmitter?

A: The transmitter is designed for wall or surface mounting using the provided wall mounting kit. Simply follow the instruction manual for connecting the 1/8 NPT female threads to your process lines and ensure a 24 VDC power supply is available.

Q: What types of media can the DPT1-R8 measure pressure for?

A: The DPT1-R8 is suitable for measuring the differential pressure of steam, oil, and gas, making it versatile for a variety of industrial applications.

Q: When should I calibrate or adjust the transmitter?

A: Calibration or adjustment is recommended during initial setup and periodically based on your application's maintenance schedule. The transmitter features push-button zero and span adjustments for convenient recalibration as needed.

Q: Where can this pressure transmitter be used?

A: With its industrial-grade design and temperature range of -10C to +50C, the DPT1-R8 can be used in diverse industrial environments such as process plants, HVAC systems, or manufacturing facilities handling steam, oil, or gas.

Q: What is the process for zero and span adjustment on this model?

A: Zero and span adjustments can be performed using the integrated push buttons on the device. Detailed instructions are provided in the manual, facilitating easy recalibration without the need for specialized tools.

Q: How does the transmitter benefit industrial operations?

A: The DPT1-R8 provides reliable, real-time monitoring with high accuracy and a fast response time (<1 s), ensuring efficient and safe process control. Its durable IP54-rated housing and easy maintenance enhance operational reliability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Differential Pressure Transmitter-Sensocon USA Category

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 380 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 380 mmWC

Minimum Order Quantity : 5 Pieces

Material : Other, ABS Plastic Housing

Seal Material : Silicone

Scale Range : 0 380 mmWC

Thread : 1/8 NPT Female

Accessories : Mounting Bracket, Instruction Manual

Sensocon USA Series DPT1-R8 - Range -1.0 - 01.0 in WC

Sensocon USA Series DPT1-R8 - Range -1.0 - 01.0 in WC

Minimum Order Quantity : 5 Pieces

Material : Other, ABS Plastic, Electronic Components

Seal Material : Silicone Oring

Scale Range : 1.0 to 1.0 in WC

Thread : 1/8 NPT Female

Accessories : Mounting Kit, Instruction Manual

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 3750 Pa

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 3750 Pa

Minimum Order Quantity : 5 Pieces

Material : Other, ABS Plastic Body

Seal Material : Silicone

Scale Range : 0 3750 Pa

Thread : 1/8 NPT Female

Accessories : Mounting Screws, Installation Manual

Sensocon USA Series DPT1-R8 - Range -0.5 - .05 in WC

Sensocon USA Series DPT1-R8 - Range -0.5 - .05 in WC

Minimum Order Quantity : 5 Pieces

Material : Other, ABS Plastic Housing

Seal Material : Silicone

Scale Range : 0.5 to 0.05 in WC

Thread : Pushon Connectors

Accessories : Mounting Screws, Installation Manual