Back to top
Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 50 mbar
Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 50 mbar

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 50 mbar

MOQ : 5 Pieces

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 50 mbar Specification

  • Outer Size
  • 110 mm x 90 mm x 55 mm (approx.)
  • Thread
  • 1/8 NPT Female
  • Seal Material
  • Silicone
  • Display
  • Digital LCD
  • Sensor Type
  • Differential Pressure Sensor
  • Grade
  • Industrial
  • Material
  • ABS/Polycarbonate Housing
  • Processing Type
  • Electronic
  • Mount Type
  • Wall Mount / Panel Mount
  • Scale Range
  • 0 - 50 mbar
  • Accuracy
  • 1.0% F.S.
  • Accessories
  • Mounting Clips, User Manual
  • Application
  • HVAC, Air Handling Units, Clean Rooms, Duct Static Pressure Monitoring
  • Temperature Range
  • -10C to +50C
  • Model
  • DPT30-R8
  • Electrical Connection
  • Screw Terminals
  • Zero and Span Adjustment
  • Yes
  • Response Time
  • <1s
  • Overpressure Limit
  • 200 mbar
  • Compliance
  • CE Marked
  • Weight
  • Approx. 200 g
  • Ingress Protection
  • IP54
  • Power Supply
  • 24V DC
  • Output Signal
  • 4-20 mA (2-wire)
 

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 50 mbar Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • FOB Port
  • delhi
  • Payment Terms
  • Cash in Advance (CID), Cash on Delivery (COD), Cash Advance (CA), Cash Against Delivery (CAD)
  • Supply Ability
  • 4 Pieces Per Day
  • Delivery Time
  • 4-6 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Middle East, Asia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 50 mbar

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 50 mbar  

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Precision in Air and Gas Monitoring

Specially optimized for differential pressure measurement, the DPT30-R8 delivers 1.0% F.S. accuracy. Its electronic design and digital LCD display provide clear, rapid results ideal for industrial and laboratory settings. The housing is finished in a sleek matt grey and built for durability under demanding conditions.


Versatile Installation Options

With flexible mounting options (wall or panel) and user-friendly electrical screw terminals, the DPT30-R8 allows for straightforward installation. Accessories such as mounting clips and a detailed user manual simplify the mounting and setup process in HVAC systems or clean room environments.

FAQs of Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 50 mbar:


Q: How does the Sensocon DPT30-R8 transmitter benefit HVAC and clean room applications?

A: The DPT30-R8 ensures reliable monitoring of differential pressure to maintain optimal airflow and environmental control in HVAC systems and clean rooms, helping to guarantee regulatory compliance and stable system performance.

Q: What process is involved in installing the DPT30-R8 transmitter?

A: Installation is straightforward: secure the transmitter using wall or panel mounts with the provided clips, connect wiring via screw terminals according to the manual, hook up pressure sources to the 1/8 NPT female threads, and power the unit with 24V DC.

Q: When should zero and span adjustments be made on this transmitter?

A: Zero and span adjustments should be performed during initial setup and periodically for recalibration, especially after maintenance or changes in application conditions, to ensure the transmitter maintains peak accuracy.

Q: Where can the DPT30-R8 be used safely and effectively?

A: This transmitter is suitable for use in controlled indoor environments such as air handling units, ductwork, clean rooms, and other industrial facilities measuring air or non-corrosive gas pressure, within its IP54-rated enclosure.

Q: What are the main usage advantages offered by the DPT30-R8?

A: Key advantages include rapid response time (<1s), high accuracy (1.0% F.S.), easy-to-read digital LCD, robust industrial-grade construction, and simple integration into electronic systems using standard analog output.

Q: How do you ensure ongoing optimal performance from the DPT30-R8?

A: Routine maintenance involves checking for secure electrical connections, regular inspection of pressure lines for blockage, and periodic recalibration using the zero and span features as described in the user manual.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Differential Pressure Transmitter-Sensocon USA Category

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 2.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 2.5 mbar

Minimum Order Quantity : 5 Pieces

Sensor Type : Differential Pressure Transmitter

Grade : Industrial

Accuracy : 1% of full scale

Processing Type : Other, Microprocessorbased

Material : Other, ABS Housing

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -12.5 - 12.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -12.5 - 12.5 mbar

Minimum Order Quantity : 5 Pieces

Sensor Type : Differential Pressure Transmitter

Grade : Industrial

Accuracy : 1% of Full Scale

Processing Type : Other, Electronic

Material : Other, Flame Retardant ABS Plastic

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -25 - 25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -25 - 25 mbar

Minimum Order Quantity : 5 Pieces

Sensor Type : Differential Pressure

Grade : Industrial

Accuracy : 1% of Full Scale

Processing Type : Other, Precision Calibrated

Material : Other, ABS Plastic, Aluminium

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 7500 Pa

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 7500 Pa

Minimum Order Quantity : 5 Pieces

Sensor Type : Differential Pressure Sensor

Grade : Industrial Grade

Accuracy : 1.5% of full scale

Processing Type : Other, Electronic

Material : Other, ABS Plastic (Housing)