About Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 127 mmWC
Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 127 mmWC
APPLICATIONS
DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms
WARNING
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.
Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.
To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.
To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.
Retain these instructions for future reference.
This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device.
SPECIFICATIONS
Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error
Thermal Effects Temperature compensated across the full spectrum of capability
Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC
Zero Point Calibration Automatic with function or Manual push-button Auto-Zero
Response Time 4.0 0.8 sec, Selectable via Jumper
Technical Specifications Media Compatibility Dry air or non-aggressive gases
Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive
Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing
Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3
Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm)
Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2
Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)
Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure
Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k
Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4
Precision Differential Pressure MonitoringThe Series DPT10-R8 excels in delivering fast and accurate differential pressure measurements for industrial processes. With a response time of less than 1 second, it ensures reliable performance for critical applications involving steam, oil, or gas. Its electronic sensing and robust ABS housing contribute to both efficiency and durability in demanding environments.
Simple Installation & Easy CalibrationFeaturing both panel and wall mounting options, the DPT10-R8 offers flexibility during installation. The device includes mounting screws and a comprehensive manual, simplifying setup. Pushbutton calibration allows for quick zero and span adjustments, minimizing downtime and ensuring ongoing measurement accuracy.
Engineered for Industrial LongevityWith an IP54 protection class and an ABS plastic body, this transmitter is built to withstand exposure to dust and water splashes. The EPDM seal further enhances durability, and the transmitter's design supports consistent operation across a broad temperature range from -10C to +60C.
FAQ's of Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 127 mmWC:
Q: How is the Sensocon DPT10-R8 differential pressure transmitter installed?
A: The Series DPT10-R8 can be installed on a panel or mounted on a wall using the supplied screws and installation manual. Its 6 mm (1/4-inch) barbed nipple and screw fitting options ensure secure connections for pressure lines.
Q: What types of media can the DPT10-R8 measure pressure for?
A: This transmitter is compatible with dry air and non-ionizing gases, making it suitable for monitoring pressure in steam, oil, and gas applications across various industrial settings.
Q: When should I perform zero and span calibration on this transmitter?
A: Calibration should be done during initial installation and whenever you notice any drift or need to maintain measurement accuracy. Pushbutton adjustment makes this process straightforward and quick.
Q: Where is the Sensocon DPT10-R8 typically used?
A: It is widely used in industrial environments such as manufacturing plants, process facilities, and HVAC systems, where monitoring differential pressure is critical for process control and safety.
Q: What is the main benefit of using the DPT10-R8 transmitter?
A: The main advantage is its precise, real-time pressure monitoring with a rapid response time of less than 1 second, ensuring reliable data for industrial process management and system safety.
Q: How does the protection class IP54 benefit industrial users?
A: The IP54 rating safeguards the transmitter against dust ingress and water splashes, making it robust for challenging factory or field conditions without compromising performance.