Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -622 - 622 Pa Specification

  • Seal Material
  • Silicone
  • Thread
  • 1/8 NPT Female
  • Grade
  • Industrial
  • Sensor Type
  • Differential Pressure Sensor
  • Display
  • LCD Digital
  • Outer Size
  • Approx. 90 x 90 x 36 mm
  • Material
  • ABS Plastic, Electronic Components
  • Processing Type
  • Electronic
  • Diameter
  • 90 mm
  • Mount Type
  • Wall Mount
  • Scale Range
  • -622 to +622 Pa
  • Accuracy
  • 1% of Full Scale
  • Accessories
  • Mounting kit, Manual
  • Temperature Range
  • -10C to +50C
  • Protection Class
  • IP54
  • Weight
  • Approx. 200 g
  • Zero and Span Adjustment
  • Button Accessible
  • Model
  • DPT10-R8
  • Output Signal
  • 4-20 mA & 0-10 V (Selectable)
  • Response Time
  • < 1 s
  • Electrical Connection
  • Screw terminal block
  • Supply Voltage
  • 24 VDC (15-36 VDC)
 

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -622 - 622 Pa Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • FOB Port
  • delhi
  • Payment Terms
  • Cash in Advance (CID), Cash on Delivery (COD), Cash Advance (CA), Cash Against Delivery (CAD)
  • Supply Ability
  • 4 Pieces Per Day
  • Delivery Time
  • 4-6 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Asia, Middle East
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -622 - 622 Pa

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -622 - 622 Pa

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4


Versatile Output and High Compatibility

With selectable 4-20 mA and 0-10 V output options, the DPT10-R8 seamlessly integrates with both analog and digital control systems. The universal 1/8 NPT female thread and screw terminal block ensure steady connections in diverse industrial settings, providing adaptability in usage scenarios.


Precise and Responsive Pressure Monitoring

Capable of measuring differential pressures from -622 to +622 Pa with 1% full-scale accuracy, the DPT10-R8 delivers reliable data for controlling steam, oil, and gas processes. The less-than-1-second response time supports quick decision-making and system feedback.


User-Friendly and Durable Design

Featuring an easy-to-read LCD digital display and button-accessible zero and span adjustments, the DPT10-R8 simplifies calibration and daily operation. The ABS plastic construction, silicone seals, and IP54 protection ensure durability in challenging industrial environments.

FAQ's of Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -622 - 622 Pa:


Q: How do I select the output signal for the DPT10-R8 differential pressure transmitter?

A: The output signal can be switched between 4-20 mA and 0-10 V by configuring the device accordingly during installation. Refer to the manual provided in the accessories for detailed setup instructions.

Q: What types of media can the DPT10-R8 measure pressure in?

A: This transmitter is engineered to detect differential pressure in steam, oil, and gas, making it suitable for a wide variety of industrial process monitoring applications.

Q: Where should the DPT10-R8 transmitter be installed for optimal performance?

A: It is designed for wall mounting and should be fixed in a location with minimal vibration and within its operating temperature range of -10C to +50C to ensure accurate measurements and device longevity.

Q: What is the process for zero and span adjustment on this device?

A: Zero and span adjustments are easily made via the accessible buttons on the unit's interface. Simply follow the step-by-step instructions provided in the included manual to fine-tune your measurements.

Q: Which power supply voltage is required to operate the DPT10-R8?

A: The device requires a supply voltage of 24 VDC, with an operational range from 15 to 36 VDC, making it compatible with most industrial power setups.

Q: What are the practical benefits of using the DPT10-R8 in industrial applications?

A: The DPT10-R8 offers fast, accurate differential pressure monitoring, robust build quality, and straightforward installation-all essential for efficient process control, safety, and system optimization in industrial environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Differential Pressure Transmitter-Sensocon USA Category

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 75 mbar

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 75 mbar

Minimum Order Quantity : 5 Pieces

Outer Size : Approx. 98mm x 87mm x 59mm

Accessories : Mounting screws, Instruction manual

Sensor Type : Piezoresistive differential pressure sensor

Grade : Industrial

Processing Type : Other, Temperature Compensated Signal Processing

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 10 inWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 10 inWC

Minimum Order Quantity : 5 Pieces

Outer Size : Approx. 110 mm x 80 mm x 35 mm

Accessories : Mounting Screws, Instruction Manual

Sensor Type : Differential Pressure Transmitter

Grade : Industrial Grade

Processing Type : Other, Electronic

Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range  -5.0 - 5.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -5.0 - 5.0 inWC

Minimum Order Quantity : 5 Pieces

Outer Size : Approx. 120mm x 90mm x 55mm

Accessories : Mounting Screws, Installation Manual

Sensor Type : Differential Pressure Sensor

Grade : Industrial

Processing Type : Other, Electronic

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 62.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 62.5 mbar

Minimum Order Quantity : 5 Pieces

Outer Size : See Diameter

Accessories : Mounting screws (included), installation manual

Sensor Type : Differential Pressure Sensor

Grade : Industrial

Processing Type : Other, Electronic