Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 125 Pa Specification

  • Display
  • No Local Display
  • Outer Size
  • 93 x 93 x 36 mm (approximate)
  • Grade
  • Industrial Grade
  • Thread
  • No Thread (Push-fit/Flanged)
  • Seal Material
  • Silicone
  • Sensor Type
  • Differential Pressure Transmitter
  • Material
  • ABS Housing, PCB Electronic Components
  • Processing Type
  • Factory Calibrated
  • Mount Type
  • Wall Mount
  • Scale Range
  • 0 - 125 Pa
  • Accuracy
  • 1.0% of Full Scale
  • Accessories
  • Mounting Screws, Calibration Certificate, User Manual
  • Output Signal
  • 4-20 mA, 2-wire
  • Response Time
  • < 5 ms
  • Protection Class
  • IP54
  • Electrical Connection
  • Screw Terminal Block
  • Media Compatibility
  • Dry, Clean, Non-Aggressive Gases
  • Operating Temperature Range
  • -10C to +60C
  • Power Supply
  • 12-36 VDC
  • Zero & Span Adjustment
  • Yes, via potentiometer
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 125 Pa Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • FOB Port
  • delhi
  • Payment Terms
  • Cash Against Delivery (CAD), Cash Advance (CA), Cash on Delivery (COD), Cash in Advance (CID)
  • Supply Ability
  • 4 Pieces Per Day
  • Delivery Time
  • 4-6 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Asia, Middle East
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 125 Pa

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 125 Pa

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Precise Differential Pressure Measurement

Engineered for industrial-grade accuracy, the DPT1-R8 differential pressure transmitter covers a range from 0 to 125 Pa with an accuracy of 1.0% of full scale. Its fast response time of less than 5 milliseconds ensures real-time monitoring and control in critical applications.


User-Friendly Setup and Maintenance

Installation is straightforward thanks to a compact wall-mountable design and screw terminal block electrical connection. Zero and span can be easily adjusted with onboard potentiometers to suit specific application needs, saving time during setup and calibration.


Rugged and Reliable Construction

Housed in durable ABS plastic, the transmitter meets IP54 protection standards, shielding it from splashes and dust. Factory calibration and included accessories (mounting screws and calibration certificate) make it ready for immediate deployment in demanding environments.

FAQ's of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 125 Pa:


Q: How is the Sensocon DPT1-R8 differential pressure transmitter installed?

A: The DPT1-R8 is designed for wall mounting using the supplied mounting screws. Electrical connections are made through a screw terminal block, making installation simple and secure.

Q: What types of media are compatible with this transmitter?

A: This transmitter is suitable for measuring dry, clean, non-aggressive gases and can be used to monitor the pressure of steam, oil, and various gases within the specified range.

Q: When should I adjust the zero and span settings, and how is it done?

A: Zero and span adjustments should be made during initial installation or recalibration. These adjustments are conveniently performed via potentiometers located on the device, allowing fine-tuning to meet application requirements.

Q: Where can this differential pressure transmitter be used?

A: The DPT1-R8 is intended for industrial environments and can be installed indoors wherever accurate differential pressure monitoring of compatible gases is required. Its IP54 rating provides protection against dust and limited water ingress.

Q: What is the process for calibrating the transmitter?

A: The unit is factory-calibrated and supplied with a calibration certificate. If re-calibration is needed, follow the instructions in the user manual and use the zero and span potentiometers for adjustments.

Q: What are the benefits of using a 4-20 mA 2-wire output signal?

A: A 4-20 mA 2-wire output is highly reliable for industrial applications, as it is immune to signal loss over long cable distances and provides consistent readings for control systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Differential Pressure Transmitter-Sensocon USA Category

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 6.4 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 6.4 mmWC

Minimum Order Quantity : 5 Pieces

Accessories : Mounting Screws, Installation Manual

Sensor Type : Differential Pressure Transmitter

Scale Range : 0 6.4 mmWC

Accuracy : 1% of Full Scale

Material : Other, ABS Plastic Housing

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25 mbar

Minimum Order Quantity : 5 Pieces

Accessories : Mounting screws, installation manual included

Sensor Type : Differential Pressure Sensor

Scale Range : 0 25 mbar

Accuracy : 1% of full scale

Material : Other, Housing: ABS Plastic

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -12.5 - 12.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -12.5 - 12.5 mbar

Minimum Order Quantity : 5 Pieces

Accessories : Mounting Screws, Installation Manual

Sensor Type : Differential Pressure Transmitter

Scale Range : 12.5 to +12.5 mbar

Accuracy : 1% of Full Scale

Material : Other, Flame Retardant ABS Plastic

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 0.62 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 0.62 mbar

Minimum Order Quantity : 5 Pieces

Accessories : Mounting Screws, Instruction Manual

Sensor Type : Differential Pressure Transmitter

Scale Range : 0 0.62 mbar

Accuracy : 1% of Full Scale

Material : Other, ABS Plastic Housing, Silicon Sensor