About Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -1250 - 1250 Pa
Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -1250 - 1250 Pa
APPLICATIONS
DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms
WARNING
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.
Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.
To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.
To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.
Retain these instructions for future reference.
This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device.
SPECIFICATIONS
Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error
Thermal Effects Temperature compensated across the full spectrum of capability
Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC
Zero Point Calibration Automatic with function or Manual push-button Auto-Zero
Response Time 4.0 0.8 sec, Selectable via Jumper
Technical Specifications Media Compatibility Dry air or non-aggressive gases
Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive
Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing
Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3
Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm)
Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2
Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)
Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure
Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k
Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4
Precision Measurement with Industrial DurabilityEngineered for reliability, the Sensocon DPT10-R8 guarantees precise differential pressure readings for steam, oil, and gas. Its rugged ABS housing and silicone seals provide secure, long-lasting performance even in challenging industrial settings. The device's rapid response time and user-friendly digital adjustment simplify pressure monitoring and maintenance.
Versatile Application and Easy InstallationFeaturing a wide measurement range and LED display, this transmitter meets various process requirements. Supplied with mounting screws and an instruction manual, it supports straightforward wall mounting through its compact size and standardized 1/8 NPT female thread. Ideal for industrial operations, it combines flexibility, clarity, and ease of use.
FAQ's of Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -1250 - 1250 Pa:
Q: How do I calibrate the DPT10-R8 pressure transmitter?
A: You can calibrate the Sensocon DPT10-R8 using its easy push-button digital zero and span adjustment located on the unit for precise setup.
Q: What is the primary use of the DPT10-R8 transmitter?
A: The main application of this transmitter is to accurately measure the differential pressure of steam, oil, and gas in industrial environments, ensuring optimal process control.
Q: When should the DPT10-R8 be used?
A: Use the DPT10-R8 whenever you require high-precision, real-time differential pressure monitoring, especially within the range of -1250 to +1250 Pa in process industries.
Q: Where is the DPT10-R8 typically installed?
A: This transmitter is designed for wall mounting in control rooms, process areas, or on-site locations where differential pressure measurement is essential.
Q: What is the installation process for the DPT10-R8?
A: Installation involves securing the unit to a wall using the provided screws, connecting the 1/8 NPT female thread to your process line, and wiring the 24V DC power supply for operation.
Q: What benefits does the LED display provide?
A: The integrated LED display allows for direct, easy-to-read monitoring of differential pressure values, which improves operational visibility and response time.
Q: How does the DPT10-R8 ensure durability and protection?
A: The device features robust ABS plastic housing, silicone seals, and an IP54 protection rating, safeguarding it against dust and moderate water exposure for reliable long-term performance.