Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 2.5 inWC Specification

  • Sensor Type
  • Differential Pressure Sensor
  • Thread
  • 1/8 NPT female
  • Display
  • No (Transmitter Output)
  • Grade
  • Industrial
  • Seal Material
  • Silicone
  • Outer Size
  • Approx. 110 mm x 80 mm x 41 mm
  • Material
  • ABS Plastic (Housing), Silicon Sensor
  • Processing Type
  • Electronic, Solid-State
  • Mount Type
  • Wall Mount
  • Scale Range
  • 0 - 2.5 inWC (Inches of Water Column)
  • Accuracy
  • 1% of FS
  • Accessories
  • Mounting Screws, Installation Instructions
  • Response Time
  • <10 ms
  • Overpressure Limit
  • 15 inWC
  • Power Supply
  • 10-36 VDC
  • Temperature Range
  • -20C to +70C
  • Output Signal
  • 4-20 mA, 2-wire
  • Electrical Connection
  • Screw Terminals
  • Product Model
  • DPT10-R8
  • Weight
  • Approx. 200 g
  • Protection Class
  • IP54
 

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 2.5 inWC Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • FOB Port
  • delhi
  • Payment Terms
  • Cash in Advance (CID), Cash Against Delivery (CAD), Cash Advance (CA), Cash on Delivery (COD)
  • Supply Ability
  • 4 Pieces Per Day
  • Delivery Time
  • 4-6 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Asia, Middle East
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 2.5 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 2.5 inWC

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Accurate Measurement in Demanding Environments

The DPT10-R8 Differential Pressure Transmitter provides reliable and accurate readings of pressure differences in industrial settings. Built for measurement of steam, oil, or gas, it is equipped with a solid-state silicon sensor to ensure precision even in challenging conditions. The transmitter is housed in a durable ABS plastic enclosure, providing optimal protection and long-lasting performance.


Designed for Simple Installation and Fast Response

This device is engineered for convenient wall mounting, using included mounting screws and installation instructions. Its screw terminal electrical connection and compact size (approx. 110 mm x 80 mm x 41 mm) make setup straightforward. With a rapid response time of less than 10 milliseconds, the transmitter delivers real-time pressure data for immediate process control.


Industrial-Grade Durability and Versatility

Featuring an IP54 protection class, the DPT10-R8 is resilient against dust and water spray, ideal for a range of industrial environments. Its robust ABS plastic housing and silicon sensor ensure stable performance across wide temperature extremes, from -20C to +70C. This makes it suitable for use in diverse applications, from process automation to HVAC systems.

FAQ's of Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 2.5 inWC:


Q: How does the Sensocon DPT10-R8 Differential Pressure Transmitter operate in industrial environments?

A: The DPT10-R8 operates by electronically measuring the differential pressure between two points using a silicon sensor. It converts this measurement to a 4-20 mA analog output signal, enabling integration with industrial control and monitoring systems in applications involving steam, oil, or gas.

Q: What is the installation process for the DPT10-R8 transmitter?

A: The transmitter is designed for easy wall mounting and comes with the required mounting screws and installation instructions. Simply attach the unit using the provided hardware, connect to your process lines with 1/8 NPT female threads, and wire to your control system via screw terminals.

Q: When is it advisable to use this differential pressure transmitter?

A: The DPT10-R8 is best used when accurate and real-time differential pressure measurement is essential, such as in process control, filtration monitoring, or HVAC applications, especially where the measured media are steam, oil, or gas within the rated pressure and temperature ranges.

Q: Where can the DPT10-R8 be applied in a facility?

A: This device can be installed in any suitable indoor industrial location, such as mechanical rooms, process lines, or HVAC ducts, provided the ambient environment falls within the temperature range of -20C to +70C and complies with its IP54 protection rating.

Q: What is the benefit of using a transmitter without a display?

A: A transmitter without a display, like the DPT10-R8, is ideal for remote or automated systems where pressure data is transmitted to a central controller, DCS, or SCADA system. This reduces on-site monitoring requirements and streamlines data collection and analysis.

Q: How is the differential pressure measurement output utilized?

A: The 4-20 mA output from the transmitter is commonly used by industrial PLCs, DCS, or monitoring systems to represent the measured pressure range (0-2.5 inWC). This current loop enables long-distance signal transmission with minimal loss, ensuring accurate data for process control.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Differential Pressure Transmitter-Sensocon USA Category

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -64 - 64 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -64 - 64 mmWC

Minimum Order Quantity : 5 Pieces

Material : Other, ABS Plastic Housing

Scale Range : 64 to 64 mmWC

Sensor Type : Differential Pressure Sensor

Accessories : Mounting Accessories Included

Grade : Industrial

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 12.7 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 12.7 mmWC

Minimum Order Quantity : 5 Pieces

Material : Other, Glass fiber reinforced polycarbonate housing

Scale Range : 0 12.7 mmWC

Sensor Type : Differential Pressure Transmitter

Accessories : Mounting screws, installation manual

Grade : Industrial

Sensocon USA Series DPT1-R8 - Range -0.25 - 0.25 in WC

Sensocon USA Series DPT1-R8 - Range -0.25 - 0.25 in WC

Minimum Order Quantity : 5 Pieces

Material : Other, ABS Plastic

Scale Range : 0.25 to +0.25 in WC (Inches Water Column)

Sensor Type : Differential Pressure Sensor

Accessories : Mounting Screws, User Manual

Grade : Industrial

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 12.7 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 12.7 mmWC

Minimum Order Quantity : 5 Pieces

Material : Other, ABS Plastic Body

Scale Range : 0 12.7 mmWC

Sensor Type : Differential Pressure Sensor

Accessories : Mounting Screws, Instruction Manual

Grade : Industrial Grade