Back to top
Sensocon USA Series DPT1-R8 - Range -1.0 - 01.0 in WC
Sensocon USA Series DPT1-R8 - Range -1.0 - 01.0 in WC

Sensocon USA Series DPT1-R8 - Range -1.0 - 01.0 in WC

MOQ : 5 Pieces

Sensocon USA Series DPT1-R8 - Range -1.0 - 01.0 in WC Specification

  • Sensor Type
  • Differential Pressure Sensor
  • Thread
  • 1/8 NPT Female
  • Seal Material
  • Silicone O-ring
  • Outer Size
  • Standard Housing
  • Display
  • Digital LCD
  • Grade
  • Industrial
  • Material
  • ABS Plastic, Electronic Components
  • Processing Type
  • Electronic
  • Diameter
  • Approx. 120 mm
  • Mount Type
  • Wall Mount
  • Scale Range
  • -1.0 to 1.0 in WC
  • Accuracy
  • 1% of Full Scale
  • Accessories
  • Mounting Kit, Instruction Manual
  • Temperature Range
  • 0 to 50C
  • Output
  • 4-20 mA Analog
  • Protection Level
  • IP54
  • Operating Humidity
  • 0-95% RH (Non-Condensing)
  • Weight
  • Approx. 250 g
  • Power Supply
  • 24V DC
  • Response Time
  • <1 second
 

Sensocon USA Series DPT1-R8 - Range -1.0 - 01.0 in WC Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • FOB Port
  • delhi
  • Payment Terms
  • Cash in Advance (CID), Cash on Delivery (COD), Cash Advance (CA), Cash Against Delivery (CAD)
  • Supply Ability
  • 4 Pieces Per Day
  • Delivery Time
  • 4-6 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Middle East, Asia
  • Main Domestic Market
  • All India
 

About Sensocon USA Series DPT1-R8 - Range -1.0 - 01.0 in WC

Sensocon USA Series DPT1-R8 - Range -1.0 - 01.0 in WC

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Reliable Differential Pressure Measurement

The DPT1-R8 provides accurate monitoring of differential pressures in industrial processes, ensuring operational reliability and efficiency. Its robust construction, digital LCD display, and high accuracy help maintain pressure control in critical applications. Designed for harsh environments, it handles pressures from steam, gas, or oil, making it versatile across various industries.


User-Friendly Installation and Operation

Installation is straightforward thanks to its standard housing, wall mount design, and included mounting kit. The digital display allows users to see real-time pressure readings at a glance, while the 4-20 mA output easily integrates with control systems. The included instruction manual supports hassle-free setup for a smooth start-up.

FAQ's of Sensocon USA Series DPT1-R8 - Range -1.0 - 01.0 in WC:


Q: How does the Sensocon USA Series DPT1-R8 measure pressure?

A: The DPT1-R8 uses an advanced electronic differential pressure sensor to measure and display pressure differences in the range of -1.0 to 1.0 inches WC, providing quick and accurate readings on its digital LCD.

Q: What types of media can this differential pressure sensor measure?

A: This sensor can measure differential pressure in steam, oil, and gas, making it suitable for various industrial applications where monitoring these media is essential.

Q: When should I use the 4-20 mA analog output feature?

A: You should use the 4-20 mA analog output when you need to transmit pressure readings to a remote monitoring or control system, ensuring continuous real-time data integration into your process automation setup.

Q: Where can the DPT1-R8 be installed securely?

A: The DPT1-R8 is designed for wall mounting and comes with a mounting kit. With its IP54-rated ABS plastic housing, it can be installed in indoor industrial environments, providing protection against dust and splashing water.

Q: What is the installation process for this device?

A: Installation involves mounting the unit on a wall with the provided kit, connecting the 1/8 NPT female threads to your process lines, wiring the 24V DC power supply, and following the instruction manual for proper setup.

Q: How does using this sensor benefit industrial operations?

A: The sensor delivers quick (<1 second), precise pressure measurements with 1% full scale accuracy, helping optimize process control, improve safety, and reduce downtime in operations involving steam, oil, or gas.

Q: What are the environmental operating limits for this sensor?

A: The DPT1-R8 operates effectively within a temperature range of 0 to 50C and 0-95% relative humidity (non-condensing), meeting the demands of most industrial conditions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Differential Pressure Transmitter-Sensocon USA Category

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar

Minimum Order Quantity : 5 Pieces

Seal Material : Silicone

Material : Other, Polycarbonate (Enclosure), PCB Electronics

Thread : 1/8 NPT

Accessories : Mounting hardware, user manual

Processing Type : Other, Electronic

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 1250 Pa

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 1250 Pa

Minimum Order Quantity : 5 Pieces

Seal Material : Silicone

Material : Other, ABS Plastic

Thread : 1/8 NPT Female

Accessories : Mounting Screws, Pressure Connection Tubing

Processing Type : Other, Electronic

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 75 mbar

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 75 mbar

Minimum Order Quantity : 5 Pieces

Seal Material : NBR (Nitrile Rubber)

Material : Other, ABS/Polycarbonate (Enclosure), Silicon (Sensor)

Thread : 1/8 NPT Female

Accessories : Mounting screws, Instruction manual

Processing Type : Other, Temperature Compensated Signal Processing

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -6.2 - 6.2 - mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -6.2 - 6.2 - mbar

Minimum Order Quantity : 5 Pieces

Seal Material : Silicone

Material : Other, ABS Enclosure, Silicium Chip

Thread : DIN rail or wall mount terminals

Accessories : Mounting Screws, Manual

Processing Type : Other, Electronic Sensor