  • Display
  • Digital
  • Thread
  • G1/8 (Female)
  • Seal Material
  • Silicone
  • Grade
  • Industrial
  • Outer Size
  • 92 mm x 90 mm x 36 mm
  • Sensor Type
  • Differential Pressure Transmitter
  • Material
  • ABS / Polycarbonate Plastic
  • Processing Type
  • Electronic
  • Diameter
  • 92 mm
  • Mount Type
  • Wall Mount
  • Scale Range
  • -6.4 to 6.4 mm WC
  • Accuracy
  • 0.5% FS
  • Finishing
  • Matte/Polycarbonate Housing
  • Measure Pressure Of
  • Steam, Oil, Gas
  • Accessories
  • Mounting Screws, Instruction Manual
  • Output Signal
  • 4-20 mA (2-wire)
  • Weight
  • Approx. 150g
  • Zero & Span Adjustment
  • Push-button
  • Protection Class
  • IP54
  • Model Series
  • DPT1-R8
  • Application
  • HVAC, building automation, filter monitoring, air flow measurement
  • Electrical Connection
  • Screw Terminal Block
  • Operating Temperature Range
  • -10C to +50C
  • Pressure Connection
  • 2 ports (G1/8")
  • Supply Voltage
  • 24V DC
  • Response Time
  • <1s
  • Media Compatibility
  • Dry, clean air, non-corrosive gases
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -6.4 - 6.4 mm WC Trade Information

  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Cash in Advance (CID), Cash Advance (CA)
  • Main Export Market(s)
  • Asia
  • Main Domestic Market
  • Himachal Pradesh, Andaman and Nicobar Islands, Pondicherry, Nagaland, South India, East India, Andhra Pradesh, Assam, Arunachal Pradesh, Bihar, Chandigarh, Delhi, Gujarat, Goa, Haryana, Jammu and Kashmir, Jharkhand, Madhya Pradesh, Maharashtra, Mizoram, Meghalaya, Manipur, Punjab, Rajasthan, Sikkim, Tamil Nadu, Telangana, Tripura, West Bengal, Uttarakhand, Daman and Diu, Dadra and Nagar Haveli, Lakshadweep, Uttar Pradesh, North India, Kerala, Central India, Odisha, West India, Chhattisgarh, Karnataka, All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -6.4 - 6.4 mm WC

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -6.4 - 6.4 mm WC

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



High Precision Differential Pressure Measurement

The DPT1-R8 achieves reliable accuracy (0.5% full scale) within its -6.4 to 6.4 mm WC range. Its advanced sensor technology ensures stable monitoring of HVAC, filter status, or airflow, optimizing building performance and energy efficiency.


User-Friendly Design & Installation

This transmitter features a digital display, easy push-button zero and span adjustment, and clear screw terminal connections. The supplied mounting hardware and a compact wall-mountable design allow for quick, straightforward installation in various environments.


Robust Construction for Industrial Applications

The durable matte polycarbonate housing (IP54) protects the device in challenging industrial settings, while silicone seals and an ABS body provide extra longevity. Its dedicated pressure ports (G1/8" female) ensure secure connections and reliable operation.

FAQ's of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -6.4 - 6.4 mm WC:


Q: How does the DPT1-R8 differential pressure transmitter operate in an HVAC system?

A: The DPT1-R8 transmitter measures and monitors pressure differences across filters, ducts, or fans in HVAC systems. It uses a reliable 4-20 mA output for real-time integration with control systems, enhancing equipment efficiency and predictive maintenance.

Q: What steps are involved in installing and setting up the DPT1-R8 transmitter?

A: To install the DPT1-R8, use the included mounting screws to fix the device securely to the wall. Connect the pressure ports using G1/8" fittings, wire the screw terminal block to a 24V DC supply, then perform zero and span adjustments with the push-buttons for accurate calibration.

Q: When should zero and span adjustments be performed on this transmitter?

A: Zero and span calibration should be conducted during initial setup, after maintenance, or if the device is relocated. This ensures the device accurately reflects real-time pressure changes and maintains reliable performance in its operational environment.

Q: Where is the optimal location to install the DPT1-R8 within a facility?

A: Install the DPT1-R8 in a dry, moderate-temperature environment near the pressure points to be monitored (e.g., across filters or measuring airflow). The device is rated for -10C to +50C and is best placed on a solid wall for steady operation.

Q: What types of media are compatible with the DPT1-R8 pressure ports?

A: The transmitter is designed for use with dry, clean air or non-corrosive gases. It should not be used with liquids or aggressive gases, ensuring a long service life and maintaining measurement accuracy.

Q: What are the key benefits of using the DPT1-R8 for building automation or filter monitoring?

A: The DPT1-R8 offers precise digital measurement, rapid response, easy maintenance, and enhances overall system efficiency by enabling timely detection of pressure changes, clogged filters, or airflow issues in HVAC and automated systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Differential Pressure Transmitter-Sensocon USA Category

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -1.25 - 1.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -1.25 - 1.25 mbar

Grade : Industrial

Measure Pressure Of : Steam, Oil, Gas

Sensor Type : Differential Pressure Transmitter

Accuracy : 1% of Full Scale

Accessories : Mounting screws, instruction manual, calibration certificate

Outer Size : Approximately 80 mm x 80 mm x 35 mm

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 7500 Pa

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 7500 Pa

Grade : Industrial Grade

Measure Pressure Of : Steam, Oil, Gas

Sensor Type : Differential Pressure Sensor

Accuracy : 1.5% of full scale

Accessories : Mounting Screws, Installation Manual

Outer Size : 103 x 86 x 53 mm (L x W x D)

Sensocon USA Differential Pressure Transmitter Series DPT10-R8  - Range   0 - 1.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 1.0 inWC

Grade : Industrial

Measure Pressure Of : Steam, Oil, Gas

Sensor Type : Differential Pressure Sensor

Accuracy : 1% of Full Scale

Accessories : Mounting Screws, Installation Manual

Outer Size : 82 mm x 80 mm x 55 mm (L x W x D)

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 10 inWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 10 inWC

Grade : Industrial Grade

Measure Pressure Of : Steam, Oil, Gas

Sensor Type : Differential Pressure Transmitter

Accuracy : 1% of Full Scale

Accessories : Mounting Screws, Instruction Manual

Outer Size : Approx. 110 mm x 80 mm x 35 mm