Back to top
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 1.25 mbar
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 1.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 1.25 mbar

MOQ : 5 Pieces

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 1.25 mbar Specification

  • Display
  • No On-board Display (Transmitter Output)
  • Thread
  • 1/8 NPT Male
  • Outer Size
  • 94 mm x 73 mm x 36 mm (Housing)
  • Grade
  • Industrial
  • Seal Material
  • Nitrile Rubber
  • Sensor Type
  • Differential Pressure Sensor
  • Material
  • High Impact ABS Plastic Housing
  • Processing Type
  • Electronic
  • Mount Type
  • Wall/Surface Mount
  • Scale Range
  • 0 - 1.25 mbar
  • Accuracy
  • 1.5% of span
  • Accessories
  • Mounting screws, User manual
  • Zero/Span Adjustment
  • On device, via potentiometer
  • Electrical Connection
  • Screw terminals
  • Pressure Limiting
  • Overpressure up to 20 kPa
  • Protection Class
  • IP54
  • Weight
  • Approx. 140 grams
  • Operating Temperature Range
  • -10C to +50C
  • Power Supply
  • 12-36 VDC
  • Response Time
  • < 10 ms
  • Output Signal
  • 4-20 mA (2-wire)
  • Model Number
  • DPT1-R8
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 1.25 mbar Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • FOB Port
  • delhi
  • Payment Terms
  • Cash Advance (CA), Cash Against Delivery (CAD), Cash on Delivery (COD), Cash in Advance (CID)
  • Supply Ability
  • 4 Pieces Per Day
  • Delivery Time
  • 4-6 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Middle East, Asia
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 1.25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 1.25 mbar

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Precise Measurement for Industrial Applications

Engineered for industries requiring accurate differential pressure monitoring, the DPT1-R8 transmitter delivers dependable performance in applications involving steam, oil, and gas. Its robust construction using high-impact ABS plastic ensures resilience against harsh conditions, while a 1.5% span accuracy meets demanding industrial standards. The device's tight pressure range makes it ideal for sensitive applications.


User-Friendly Setup and Adjustments

The DPT1-R8 facilitates easy installation thanks to its wall/surface mount design and screw terminal electrical connections. Zero and span adjustments are made simple with onboard potentiometers, eliminating the need for specialized tools. Accessories like mounting screws and a user manual are included, streamlining the setup process for engineers and technicians.


Reliable Output and Versatile Integration

Delivering a standard 4-20 mA (2-wire) signal, the transmitter integrates smoothly with most industrial control and monitoring systems. Its fast response time of under 10 ms supports real-time feedback, while the IP54-rated enclosure guards against dust and splashes, ensuring reliable long-term operation in demanding settings.

FAQ's of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 1.25 mbar:


Q: How is the Sensocon DPT1-R8 Differential Pressure Transmitter typically installed?

A: The transmitter is designed for wall or surface mounting, using the provided mounting screws. Its screw terminal connections facilitate straightforward wiring to your process control system.

Q: What process media can the DPT1-R8 transmitter measure pressure in?

A: The DPT1-R8 is suitable for differential pressure measurement in steam, oil, and gas applications, making it versatile for a range of industrial processes.

Q: When should zero and span adjustments be performed on this device?

A: Zero and span adjustments should be performed during installation and periodically during scheduled maintenance to ensure ongoing measurement accuracy.

Q: Where is the DPT1-R8 best utilized within an industrial setting?

A: This transmitter is best suited for use in industrial environments where precise low-range differential pressure measurements are required, such as in process monitoring, filtration systems, or HVAC control.

Q: What output signal does the DPT1-R8 provide and how is it integrated?

A: The device produces a standard 4-20 mA (2-wire) analog output, which can be integrated into most industrial control or monitoring systems for real-time data acquisition.

Q: How does the DPT1-R8 handle overpressure conditions?

A: The transmitter can tolerate temporary overpressure up to 20 kPa, protecting the sensor from occasional process surges.

Q: What are the benefits of choosing the DPT1-R8 for pressure monitoring?

A: Users benefit from its compact, robust design, fast response time, reliable accuracy, and straightforward installation and calibration, ensuring trouble-free operation in demanding industrial applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Differential Pressure Transmitter-Sensocon USA Category

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 10.0 inWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 10.0 inWC

Minimum Order Quantity : 5 Pieces

Mount Type : Other, Panel or duct mount

Accuracy : 1% of full scale

Display : Digital display (LCD)

Thread : 1/8 NPT female

Material : Other, ABS plastic housing, electronic components

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 125 Pa

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 125 Pa

Minimum Order Quantity : 5 Pieces

Mount Type : Other, Wall Mount

Accuracy : 1% of Full Scale

Display : LCD Digital Display

Thread : 1/8 NPT Female

Material : Other, ABS Plastic Housing

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 64 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 64 mmWC

Minimum Order Quantity : 5 Pieces

Mount Type : Other, Wall / Surface Mountable

Accuracy : 1% of Full Scale

Display : LCD Digital Display

Thread : 1/8 NPT Female

Material : Other, ABS Plastic Body

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 6.2 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 6.2 mbar

Minimum Order Quantity : 5 Pieces

Mount Type : Other, Wall / Surface Mount

Accuracy : 1.5% FS

Display : No (420 mA output only)

Thread : 1/8 NPT Female

Material : Other, ABS Plastic, Electronics