About GEMTECH* Differential Pressure Gauge*Distributor For Bhagalpur Bihar
GEMTECH* Differential Pressure Gauge*Distributor For Bhagalpur Bihar
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine,resistance of Filter,Wind Speed, Furnace Pressure,Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION
- Ambient Temperature - -21 ~140 -6 ~60
- Rated Pressure -20 inHg~30 inHg (-68~103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - A2% of full span at 70 21 3% on -0, and A4% on -00)
- Range -20 inHg~38 inHg (-68KPa~130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERINGGEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model |
Description |
| G2000-100MM |
DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
DPG,Range 0-150 MM W.C. |
| G2000-15MM |
DPG,Range 0-15 MM W.C. |
| G2000-200MM |
DPG,Range 0-200 MM W.C. |
| G2000-250MM |
DPG,Range 0-250 MM W.C. |
| G2000-25MM |
DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
DPG,Range 0-300 MM W.C. |
| G2000-50MM |
DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
Exceptional Accuracy and VersatilityThe GEMTECH Differential Pressure Gauge ensures consistently accurate readings with a tolerance of 2% of the full span, even under varying temperatures. Suitable for a wide range of industries, its stainless steel construction and analog display offer robust performance and clarity, regardless of the pressure medium. The unit accommodates multiple measurement scales, ensuring flexibility for user-specific requirements.
Sturdy Construction and Easy InstallationDesigned with industrial environments in mind, this gauge features a strong stainless steel body, polished and treated for longevity. The 4-inch size and back mount type simplify installation on equipment. Duplicate high and low pressure taps (1/8" female NPT) on both side and back add convenience for diverse setup scenarios, ensuring adaptability in existing systems.
Broad Application SpectrumThe GEMTECH Differential Pressure Gauge serves a multitude of sectors in Bhagalpur, Bihar, from hospitals to power plants and food processing units. Accurate measurement for steam, oil, and gas ensures enhanced process control, safety, and equipment protection, making it a vital tool across both process and utility applications.
FAQ's of GEMTECH* Differential Pressure Gauge*Distributor For Bhagalpur Bihar:
Q: How is the GEMTECH Differential Pressure Gauge used in industrial settings?
A: This gauge is installed to monitor the pressure difference between two points, such as across filters or pumps, in industries like pharmaceuticals, power plants, and food processing. By tracking pressure changes, it helps maintain process efficiency and safety.
Q: What industries can benefit from using this differential pressure gauge in Bhagalpur, Bihar?
A: Industries such as hospitals, malls, hotels, cement, steel and fertilizer plants, pharmaceutical manufacturing, the textile sector, food and beverage, and pulp and paper units can all benefit from its accurate and reliable pressure monitoring.
Q: When should the GEMTECH Differential Pressure Gauge be calibrated or checked for accuracy?
A: It is recommended to check and calibrate the gauge annually or as per your industry's maintenance schedule to ensure accuracy, especially in critical applications like hospital operating theaters or process manufacturing.
Q: Where can I install this pressure gauge for optimal results?
A: The gauge is designed for easy back mounting and can be installed on control panels, pipelines, or equipment where monitoring differential pressure is crucial, such as filters, pumps, and ventilation systems.
Q: What are the benefits of choosing this specific gauge model?
A: Benefits include high accuracy (2% of full span), robust stainless steel housing, compatibility with steam, oil, and gas, and ease of installation thanks to its standard threads and mounting options. It also offers multiple scale units to suit diverse process requirements.
Q: How is the pressure read and interpreted on the GEMTECH Differential Pressure Gauge?
A: The analog display shows the pressure difference directly in the selected units (MM WC, CM, PAC, KPA, INCH, PSI). The clear dial and aluminum pointer make readings quick and easy for operators.
Q: What is the process for connecting the gauge to my existing system?
A: Simply attach the provided 1/8" female NPT taps for high and low pressure points (side or back), using appropriate sealants and mounting supports. Ensure proper alignment and secure connection for precise readings.