About GEMTECH Differential Pressure Gauge Dealers Nr. Deen Dayal Upadhyay Hospital
GEMTECH Differential Pressure Gauge Dealers Nr. Deen Dayal Upadhyay HospitalSeries G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70(21(3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERINGGEMTECH By Model Number Popularity FILTER BY
| Model |
Description |
| G2000-100MM |
DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
DPG,Range 0-150 MM W.C. |
| G2000-15MM |
DPG,Range 0-15 MM W.C. |
| G2000-200MM |
DPG,Range 0-200 MM W.C. |
| G2000-250MM |
DPG,Range 0-250 MM W.C. |
| G2000-25MM |
DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
DPG,Range 0-300 MM W.C. |
| G2000-50MM |
DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
Built for Comprehensive Pressure MonitoringThis gauge stands out for its solid construction and precision, making it suitable for critical spaces such as hospital OTs, pharmaceutical manufacturing, power, cement, and textile industries. The use of a metal alloy body, aluminum pointer, and a selectable finish (antique, polished, or matte) ensures lasting durability and clear visibility, even in demanding conditions.
Industries and ApplicationsEngineered for adaptability, the GEMTECH Differential Pressure Gauge is perfect for pharmaceutical plants, hotels, malls, power plants, fertilizer factories, and more. Ideal for monitoring pressure in steam, oil, and gas lines, it helps maintain optimal operating conditions and safety across a multitude of professional environments.
FAQ's of GEMTECH Differential Pressure Gauge Dealers Nr. Deen Dayal Upadhyay Hospital:
Q: How is the GEMTECH Differential Pressure Gauge installed, and what mount type does it support?
A: This gauge is designed for easy installation with a back mount configuration. It can be securely fitted onto various panels or equipment commonly found in hospitals, industrial plants, and commercial buildings.
Q: What are the key industries that benefit from using this differential pressure gauge?
A: Major industries such as pharmaceuticals, hospitals, power plants, cement, fertilizer, hotel, textile, and food & beverage manufacturing benefit from its use due to its reliability in monitoring pressure for steam, oil, and gas applications.
Q: When should calibration or maintenance be performed on the gauge?
A: Periodic calibration or maintenance is recommended annually, or as specified by regulatory standards in your industry, to maintain accuracy and performance, especially in critical applications like hospital OTs or chemical plants.
Q: Where can the GEMTECH gauge be sourced and what services are available?
A: This product is available through exporters, manufacturers, suppliers, and traders across India, particularly near Deen Dayal Upadhyay Hospital. Dealers often provide after-sales support, calibration, and installation assistance.
Q: What is the accuracy and performance specification of the gauge?
A: The gauge delivers an accuracy of 2% of full span at 70F (21C), ensuring reliable readings for critical monitoring situations. For other specified conditions, accuracy may vary slightly, which is indicated in the product specifications.
Q: How does this gauge benefit facility operators in pharmaceutical and industrial sectors?
A: By offering precise differential pressure readings, this gauge helps facility operators ensure safety, maintain regulatory compliance, optimize process efficiency, and minimize downtime in sensitive and high-usage environments.