About GEMTECH Differential Pressure Gauge Dealers Nr Maharaja Agrasen Hospital
GEMTECH Differential Pressure Gauge Dealers Nr Maharaja Agrasen Hospital
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70(21(3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERINGGEMTECH By Model Number Popularity FILTER BY
| Model |
Description |
| G2000-100MM |
DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
DPG,Range 0-150 MM W.C. |
| G2000-15MM |
DPG,Range 0-15 MM W.C. |
| G2000-200MM |
DPG,Range 0-200 MM W.C. |
| G2000-250MM |
DPG,Range 0-250 MM W.C. |
| G2000-25MM |
DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
DPG,Range 0-300 MM W.C. |
| G2000-50MM |
DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
Versatile Applications Across Industries
The GEMTECH Differential Pressure Gauge is engineered for a broad spectrum of sectors, including pharmaceuticals, hospitality, power generation, cement production, steel and fertilizer plants, textiles, food and beverage, plus pulp and paper industries. Its dependable performance, even in demanding settings, ensures you can confidently select it for critical pressure monitoring tasks.
Precision Engineering and Construction
Constructed from high-grade metal alloy with a choice of antique, polished or matte finishes, this gauge combines durability with style. The accuracy rating of 2% of the full span is maintained under most conditions, making it a preferred tool where precise measurements are crucial. The black color and analog display further enhance visibility and ease of reading.
FAQ's of GEMTECH Differential Pressure Gauge Dealers Nr Maharaja Agrasen Hospital:
Q: How is the GEMTECH Differential Pressure Gauge installed?
A: This pressure gauge features a back mount design, making installation straightforward on panels or control boards. Secure the gauge using the provided hardware, ensuring connectivity to the respective pressure lines for accurate differential readings.
Q: What types of media can the gauge measure pressure for?
A: The GEMTECH Differential Pressure Gauge is compatible with steam, oil, and gas, making it suitable for diverse applications in both industrial and commercial environments.
Q: When should this differential pressure gauge be calibrated?
A: It is recommended to calibrate the gauge upon installation and then periodically according to your sector's regulatory guidelines or after intensive usage to maintain optimal accuracy (2% of full span under standard operating conditions).
Q: Where can this gauge be used effectively?
A: Ideal for usage in hospitals, OT rooms, hotels, malls, power plants, cement and steel plants, fertilizer and textile industries, pharmaceutical manufacturing, and food and beverage processing-any place where monitoring pressure differentials is vital.
Q: What are the key benefits of using this pressure gauge?
A: This gauge offers high measurement accuracy, reliable analog display, robust metal alloy construction, and flexibility in finishes. It is suitable for critical environments, ensuring safety, efficiency, and compliance.
Q: How does the accuracy specification benefit industrial processes?
A: The gauge's 2% full span accuracy at standard temperature conditions ensures precise monitoring, which is essential for process control, safety, and maintaining regulatory standards in sensitive operations.
Q: What is the process to connect the gauge to a system?
A: Attach the pressure lines to the designated inlets at the back of the gauge, taking care to follow manufacturer guidelines and sealing the connections properly to prevent leaks and ensure accurate differential readings.