About Wholesale GEMTECH Differential Pressure Gauges For Saha Haryana

Wholesale GEMTECH Differential Pressure Gauges For Saha Haryana
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine,resistance of Filter,Wind Speed, Furnace Pressure,Differential Pressure Of Pore Plate,The Pressure of drum water level,Liquid Amplifier And Hydraulic Pressure System.Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION
- Ambient Temperature - -21 ~140 -6 ~60
- Rated Pressure -20 inHg~30 inHg (-68~103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel,with acrylic cover,Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - A2% of full span at 70 (21 (A3% on -0,and A4% on -00)
- Range -20 inHg~38 inHg (-68KPa~130KPa)(Special Specification also can be ordered.)

FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model |
Description |
| G2000-100MM |
DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
DPG,Range 0-150 MM W.C. |
| G2000-15MM |
DPG,Range 0-15 MM W.C. |
| G2000-200MM |
DPG,Range 0-200 MM W.C. |
| G2000-250MM |
DPG,Range 0-250 MM W.C. |
| G2000-25MM |
DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
DPG,Range 0-300 MM W.C. |
| G2000-50MM |
DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
Reliable Pressure Monitoring Across IndustriesGEMTECH Differential Pressure Gauges provide accurate readings for a variety of applications, including pharmaceuticals, hospitals, hotels, malls, power plants, cement plants, and more. With a sturdy stainless steel body and multiple scale unit options, this gauge ensures precise pressure monitoring in steam, oil, or gas lines, helping maintain operational efficiency and safety. Its analog display and high-quality materials make it suitable for continuous industrial use.
Versatile Scale and Mounting OptionsThe gauge features a multi-unit scale range comprising MM WC, CM, PAC, KPA, INCH, and PSI, accommodating diverse measurement needs. The 4-inch (100 mm) diameter and back mount design, coupled with dual thread pairs for high and low pressure taps, support easy and flexible installation in a wide range of settings. The range of finishes, from antique to polished, enhances both functionality and appearance.
FAQ's of Wholesale GEMTECH Differential Pressure Gauges For Saha Haryana:
Q: How do I install the GEMTECH Differential Pressure Gauge for accurate readings?
A: Install the gauge using the back mount and connect the 1/8" female NPT taps to the respective high and low pressure points in your system. Ensure the installation site matches the application, and that the gauge is at the same height as the process connection to avoid errors due to hydrostatic head.
Q: What types of media can this gauge measure pressure for?
A: The GEMTECH Differential Pressure Gauge is designed to measure pressure in steam, oil, and gas applications, making it ideal for use in various industries such as power plants, textile manufacturing, food and beverage processing, and pharmaceuticals.
Q: When should this gauge be used within an industrial process?
A: Use this gauge whenever you need to monitor differential pressure across filters, pumps, or other components where precise control and monitoring are critical to system safety and efficiency. It is particularly important in processes requiring stringent pressure control, such as in hospitals, hotels, and power generation facilities.
Q: Where is the preferred location for mounting the GEMTECH Differential Pressure Gauge?
A: The preferred mounting location is in proximity to the point of measurement, typically at a convenient and easily accessible height for monitoring and maintenance. Its back mount design allows seamless integration into control panels or process lines in various industrial environments.
Q: What is the process for reading the analog display accurately?
A: Read the analog display by aligning your eye with the pointer and the measurement scale. Make note of the correct scale unit (MM WC, CM, PAC, KPA, INCH, or PSI) according to your application's needs, and record the value at which the pointer rests. This ensures accurate representation of the differential pressure.
Q: How can users benefit from using this differential pressure gauge?
A: Users benefit from improved process safety and efficiency, reliable and consistent pressure monitoring, and versatile compatibility with various industrial fluids. Its robust stainless steel build and precision engineering minimize maintenance needs, optimize operational performance, and reduce downtime.