About Suppliers GEMTECH Differential Pressure Gauges by Korba Chhattisgarh
Suppliers GEMTECH Differential Pressure Gauges by Korba Chhattisgarh
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine,resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System.Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION - Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70(21(3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)

FEATURES - OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,
- Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.
- Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS - Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERINGGEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model | Description |
| G2000-100MM | DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM | DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM | DPG,Range 0-150 MM W.C. |
| G2000-15MM | DPG,Range 0-15 MM W.C. |
| G2000-200MM | DPG,Range 0-200 MM W.C. |
| G2000-250MM | DPG,Range 0-250 MM W.C. |
| G2000-25MM | DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM | DPG,Range 0-300 MM W.C. |
| G2000-50MM | DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM | DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM | DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
Versatile Application Across IndustriesGEMTECH Differential Pressure Gauges serve a wide spectrum of environments, from hospitals and malls to power and cement plants. With customizable pressure scale ranges and rugged stainless steel construction, it ensures accurate measurement in settings like pharmaceuticals, food processing, and steel manufacturing.
Enhanced Durability and AccuracyEngineered with a back mount and a sturdy aluminum pointer, this gauge withstands challenging environments while delivering reliable readings. Its fine-tuned accuracy (2% of full span at standard temperatures) ensures confidence in monitoring pressure for critical processes.
FAQ's of Suppliers GEMTECH Differential Pressure Gauges by Korba Chhattisgarh:
Q: How do I install the GEMTECH Differential Pressure Gauge?
A: The gauge is designed with a back mount, making it simple to install on compatible panels or equipment. Ensure the area is clean and secure the gauge using appropriate fittings, aligning the ports with your process connections according to the user manual.
Q: What types of fluids or gases can this pressure gauge measure?
A: This gauge is suitable for measuring the differential pressure of steam, oil, and gas. It is constructed with materials resistant to these media, ensuring long-term performance and safety.
Q: When should the differential pressure gauge be calibrated?
A: For optimal performance, calibration is recommended annually or whenever you notice deviations in readings. Regular calibration helps maintain accuracy, especially in critical industrial processes.
Q: Where can this gauge be effectively used?
A: This gauge performs reliably in diverse applications such as pharmaceutical manufacturing, hotels, malls, hospitals, power plants, cement and steel plants, fertilizer units, textile, food and beverage, and pulp and paper industries.
Q: What is the process for reading the pressure values on this gauge?
A: Simply check the analog display, which clearly shows the current differential pressure based on your selected scale (mm WC, cm, PaC, kPa, or inch). The precise pointer enables quick, accurate readings.
Q: What are the main benefits of using this differential pressure gauge?
A: Benefits include high measurement accuracy, durable construction, suitability for various liquids and gases, and adaptability to multiple industrial applications. Its robust build ensures longevity even under demanding use.