About Suppliers GEMTECH Differential Pressure Gauges by Haldwani Uttarakhand
Suppliers GEMTECH Differential Pressure Gauges by Haldwani Uttarakhand
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System.Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION - Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 (21 (3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)

FEATURES - OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS - Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERINGGEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model | Description |
| G2000-100MM | DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM | DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM | DPG,Range 0-150 MM W.C. |
| G2000-15MM | DPG,Range 0-15 MM W.C. |
| G2000-200MM | DPG,Range 0-200 MM W.C. |
| G2000-250MM | DPG,Range 0-250 MM W.C. |
| G2000-25MM | DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM | DPG,Range 0-300 MM W.C. |
| G2000-50MM | DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM | DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM | DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
Versatile Mounting and MaterialsThese GEMTECH Differential Pressure Gauges offer back mounting for easy installation and feature a plastic dial with a reliable metal alloy body. Combined with an aluminum pointer, this construction ensures long-lasting performance even in demanding industrial and commercial environments.
High Precision for Critical ApplicationsCatering to diverse sectors like pharmaceutical, hotels, hospitals, malls, and various heavy industries, the gauges deliver accurate readings within 2% of full span for standard processing. This makes them ideal for environments requiring dependable monitoring and control.
Adaptable and Stylish FinishesChoose from antique, polished, galvanized, or matte finishing options, ensuring the gauge suits the aesthetics and durability requirements of your facility. These design choices, alongside the analog display, offer practicality and visual clarity in every installation.
FAQ's of Suppliers GEMTECH Differential Pressure Gauges by Haldwani Uttarakhand:
Q: How are GEMTECH Differential Pressure Gauges installed?
A: These gauges feature a back mount type for straightforward installation on panels or equipment, allowing for secure and visible mounting in various settings like pharmaceutical plants or hotels.
Q: What substances can these pressure gauges measure?
A: The gauges are designed to measure the pressure of steam, oil, and gas, making them suitable for a wide range of industrial processes across multiple industries.
Q: When is it essential to use a differential pressure gauge in industrial applications?
A: Differential pressure gauges are vital when monitoring and ensuring the correct operation of filtration, pump systems, or clean room environments, especially in hospitals, pharmaceutical manufacturing, and power plants.
Q: Where are these gauges typically used?
A: These gauges see broad use in environments such as hospitals, operating theatres (OTs), power plants, cement and steel plants, fertilizer, pulp and paper, textile, pharmaceutical manufacture, food and beverage industry, as well as commercial spaces like malls and hotels.
Q: What is the process for selecting the right scale range on these gauges?
A: Selection depends on your application's requirements. Available scale ranges (MM WC, CM, PAC, KPA, INCH) allow for flexibility to match your system's pressure standards and maximize accuracy and safety.
Q: How do these gauges benefit industrial and commercial facilities?
A: They provide reliable, precise monitoring of pressure differences, helping maintain optimal performance, safety, and efficiency in critical environments such as cleanrooms, pipelines, and processing lines.