About Series G2000 GEMTECH Diff Pressure Gauges
Series G2000 GEMTECH Differential Pressure Gauges
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION - Ambient Temperature - -21 ~140 -6 ~60
- Rated Pressure -20 inHg~30 inHg (-68~103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - A2% of full span at 70(21(A3% on -0, and A4% on -00)
- Range -20 inHg~38 inHg (-68KPa~130KPa)(Special Specification also can be ordered.)
FEATURES - OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS - Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERINGGEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model | Description |
| G2000-100MM | DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM | DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM | DPG,Range 0-150 MM W.C. |
| G2000-15MM | DPG,Range 0-15 MM W.C. |
| G2000-200MM | DPG,Range 0-200 MM W.C. |
| G2000-250MM | DPG,Range 0-250 MM W.C. |
| G2000-25MM | DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM | DPG,Range 0-300 MM W.C. |
| G2000-50MM | DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM | DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM | DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
Versatile Application Across Multiple IndustriesThe G2000 GEMTECH Differential Pressure Gauges are suited for diverse industries, such as pharmaceuticals, hotels, malls, hospitals, operational theaters, and large-scale manufacturing in steel, cement, fertilizer, pulp and paper, food and beverages, and textiles. Their adaptability to measure steam and gas ensures they provide precise monitoring wherever differential pressure tracking is crucial for operational safety through analog display.
Durable Design and Premium MaterialsConstructed from high-grade metal alloy and featuring an aluminum pointer, these pressure gauges guarantee longevity and resistance to demanding industrial environments. The plastic dial, available in a 4-inch (100 mm) size, is easy to read, while the selection of finishes-including antique, polished, galvanized, and matte-allows customization for aesthetic and functional integration into any workspace.
Accurate Measurement and Easy InstallationWith an accuracy of 2%, the G2000 Series offers dependable readings, enabling tight process control and incident prevention. The 1/8-inch threaded connections and back mount installation ensure ease of use and secure fitting. These gauges are lightweight at 550 grams, making installation simple and maintenance manageable across all facility settings.
FAQ's of Series G2000 GEMTECH Diff Pressure Gauges:
Q: How do I install the Series G2000 GEMTECH Differential Pressure Gauge in my facility?
A: The G2000 gauge is designed for easy installation with a back mount and a 1/8-inch threaded connection. Simply secure the gauge in the designated position on your pipe or panel, ensuring the fitting is compatible and leak-free for accurate steam or gas pressure measurement.
Q: What industries can benefit from using the Series G2000 Pressure Gauges?
A: These gauges are ideal for pharmaceutical manufacturing, hospitals, operating theaters, hotels, malls, power plants, cement plants, steel mills, fertilizer production, textile, food and beverage, as well as pulp and paper industries. They are versatile in monitoring differential pressure of both steam and gas.
Q: When should I consider using a differential pressure gauge in my process?
A: Use a differential pressure gauge when you need to monitor pressure differences between two points in a system, such as filtration, flow control, or level detection processes. The G2000 ensures process safety and regulatory compliance in critical environments.
Q: Where can these gauges be used for maximum effectiveness?
A: Install the Series G2000 gauge on pipelines, filtration units, or pressure vessels where pressure differences must be monitored, such as in cleanrooms, utility lines, or production areas across the industries mentioned above.
Q: What benefits does the analog display provide in industrial settings?
A: The analog display offers real-time, intuitive readings, making it easy for operators to monitor system performance instantly and respond quickly to abnormalities without needing specialized training.
Q: How is the scale range indicated on the dial, and in which units can I read pressure?
A: The dial displays pressure in multiple units including MM WC, CM, PAC, KPA, and INCH, ensuring you can select the measurement standard that best fits your process or regulatory requirements.
Q: What maintenance is needed for the GEMTECH G2000 Differential Pressure Gauge?
A: Regularly inspect the gauge for signs of damage or wear, ensure the dial and pointer are clean and unobstructed, and verify that the mounting and thread connections are secure. Simple upkeep helps maintain accuracy and extends the gauge's lifespan.