Back to top
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -0.62 - 0.62 mbar
Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -0.62 - 0.62 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.62 - 0.62 mbar

MOQ : 5 Pieces

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.62 - 0.62 mbar Specification

  • Grade
  • Industrial Grade
  • Thread
  • 1/8 NPT Female
  • Sensor Type
  • Differential Pressure Transmitter
  • Seal Material
  • Silicone
  • Display
  • LCD Digital Display
  • Outer Size
  • Compact Size (specific dimensions see datasheet)
  • Material
  • ABS Plastic Body
  • Processing Type
  • Electronic
  • Diameter
  • Approx. 90 mm
  • Mount Type
  • Wall Mount / Surface Mount
  • Scale Range
  • -0.62 to +0.62 mbar
  • Accuracy
  • 1% FS
  • Accessories
  • Mounting Bracket, User Manual
  • Protection Rating
  • IP65
  • Model
  • DPT1-R8
  • Weight
  • Approx. 120 g
  • Output Signal
  • 4-20 mA, 2-wire
  • Media Compatibility
  • Dry Air and Non-Aggressive Gases
  • Zero and Span Adjustment
  • Via Front Keys
  • Response Time
  • <100 ms
  • Temperature Range
  • -10C to +60C
  • Electrical Connection
  • M12 Connector or Terminal Block
  • Application
  • HVAC, Clean Rooms, Filter Monitoring
  • Overpressure Limit
  • 200 mbar
  • Power Supply
  • 24 VDC
 

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.62 - 0.62 mbar Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • FOB Port
  • delhi
  • Payment Terms
  • Cash Against Delivery (CAD), Cash Advance (CA), Cash on Delivery (COD), Cash in Advance (CID)
  • Supply Ability
  • 4 Pieces Per Day
  • Delivery Time
  • 4-6 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Asia, Middle East
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.62 - 0.62 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -0.62 - 0.62 mbar

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4



Precision Measurement for Sensitive Applications

The DPT1-R8 transmitter offers a fine-scale range from -0.62 to +0.62 mbar, ideal for monitoring differential pressure in clean rooms, HVAC ducts, and filtration systems. With 1% FS accuracy and overpressure protection up to 200 mbar, it supports critical environments where reliable, real-time data is essential for compliance and operational safety.


User-Friendly Design and Fast Setup

Featuring an intuitive front key interface for zero and span adjustment, the DPT1-R8 simplifies setup and calibration. The compact, lightweight ABS enclosure (approx. 120 g) includes a mounting bracket for easy installation, an LCD for at-a-glance readings, and flexible connection options, ensuring seamless integration into new or existing systems.

FAQ's of Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.62 - 0.62 mbar:


Q: How is the Sensocon DPT1-R8 differential pressure transmitter installed?

A: The DPT1-R8 can be mounted on walls or surfaces using the included mounting bracket. Electrical connections are simplified with options for an M12 connector or terminal block. Detailed installation steps are provided in the user manual to ensure quick and accurate setup.

Q: What types of media can be measured using this transmitter?

A: This model is suitable for measuring dry air and non-aggressive gases. It's not compatible with liquids or corrosive gases, ensuring reliable operation in HVAC, clean rooms, and similar environments.

Q: When should I use the DPT1-R8 in my facility?

A: The DPT1-R8 is ideal whenever precise differential pressure monitoring is required, such as during air balancing in HVAC systems, filter performance checks, or maintaining clean room standards. Its accuracy and quick response make it suitable for continuous monitoring applications.

Q: What is the process for zero and span adjustment?

A: Zero and span for the DPT1-R8 can be calibrated via the front keys on the device. This enables onsite fine-tuning without the need for additional tools, allowing adjustments after installation to ensure optimal measurement performance.

Q: Where is the DPT1-R8 most beneficially used?

A: It is highly beneficial in places requiring stringent environmental controls, such as clean rooms, laboratories, medical facilities, and industrial filter monitoring stations. Its compact design and high ingress protection make it adaptable to various settings.

Q: What are the benefits of the IP65-rated ABS enclosure?

A: The IP65-rated ABS enclosure protects the transmitter from dust and water ingress, ensuring longevity and stable operation even in challenging industrial or HVAC environments.

Q: How can I connect the transmitter to my control system?

A: The transmitter offers a standard 4-20 mA, 2-wire output signal, allowing easy integration with most monitoring or control systems. Electrical connection options include M12 connectors or a terminal block for flexibility in installation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Differential Pressure Transmitter-Sensocon USA Category

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 25 inWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 25 inWC

Minimum Order Quantity : 5 Pieces

Outer Size : Housing: 5.12 x 2.56 inches (approx.)

Mount Type : Other, Panel or Surface Mount

Thread : 1/8 NPT Female Pressure Ports

Sensor Type : Differential Pressure Sensor

Seal Material : Silicone/Oring Sealed

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 127 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 127 mmWC

Minimum Order Quantity : 5 Pieces

Outer Size : 85 mm x 80 mm x 36 mm (Approximate)

Mount Type : Other, Panel or Wall Mount

Thread : Barbed and Screw Fittings

Sensor Type : Differential Pressure Transmitter

Seal Material : EPDM

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 12.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 12.5 mbar

Minimum Order Quantity : 5 Pieces

Outer Size : Approx. 98 mm x 58 mm x 35 mm

Mount Type : Other, Wall Mount

Thread : G1/8 Female

Sensor Type : Differential Pressure Sensor

Seal Material : Silicone Rubber

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 762 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 762 mmWC

Minimum Order Quantity : 5 Pieces

Outer Size : Approximately 90 mm x 115 mm x 60 mm

Mount Type : Other, Wall Mount

Thread : 1/8 NPT Female

Sensor Type : Differential Pressure Sensor

Seal Material : EPDM