About Sensocon USA 211-D050K-3 Differential Pressure Transmitter From Kampagarh Kendrapara Orissa
Sensocon USA 211-D050K-3 Differential Pressure Transmitter From Kampagarh Kendrapara Orissa
- Brand - Sensocon
- MODEL - 211-D050K-3
- Pressure Range - 0-50 KPA
- ACCURACY- 0.25%
The Series 211 Differential Pressure Transmitter Can Accurately Measure Positive, Negative, Or Differential Pressure And Send The Corresponding 4 a 20 mA Output Signal. The Series 211 Differential Pressure Transmitter Is Not Position Sensitive And Can Be Mounted In Any Orientation Without Compromising Accuracy. It Also Features A Power LED, So You Always Know When The Transmitter Is Operating. The Compact, Lightweight Design Makes Installation Simple And Easy.
SpecificationsMaximum Pressure:
Ranges a 5 PSI (35kPa) =15 PSI (100kPa) MaxRanges > 5 PSI (35kPa) =30 PSI (200kPa) MaxAir And Compatible Non-Combustible,Non-Corrosive GasesRanges a 4" w.c. (1kPa) 1.0%Ranges a 5" w.c. (1.25kPa) 0.25%Compensated: 15A to 120AF (-10A to 50AC)Operating: -10A to 155AF (-25A to 70AC)
- Thermal Effect: +/- 0.028% FS/AF (+/- 0.050% FS/AC)
- Stability: +/- 0.25% FS/Year
- Output Signal: 4-20 mA, 2-Wire Or 0 - 10 V
- Loop Resistance: 250 I @ 24 VDC
- Housing Material: ABS Plastic
- Electrical Connection:Screw Terminals
- Process Connection:Push On Connection For 3/16" I.D. Tubing
Model Number
Model
|
Pressure Range |
Accuracy |
| 211-D001I-1 |
0-1" |
1% |
| 211-D002I-1 |
0-2" |
1% |
| 211-D004I-1 |
0-4" |
1% |
| 211-D006I-3 |
0-6" |
0.25% |
| 211-D010I-3 |
0-10" |
0.25% |
| 211-D020I-3 |
0-20" |
0.25% |
| 211-D040I-3 |
0-40" |
0.25% |
| 211-D005P-3 |
0-5 PSI |
0.25% |
| 211-D010P-3 |
0-10 PSI |
0.25% |
| 211-D015P-3 |
0-15 PSI |
0.25% |
| 211-D250A-1 |
0-250 Pa |
1% |
| 211-D500A-1 |
0-500 Pa |
1% |
| 211-D001K-1 |
0-1 kPa |
1% |
| 211-D002K-3 |
0-2 kPa |
0.25% |
| 211-D003K-3 |
0-3 kPa |
0.25% |
| 211-D005K-3 |
0-5 kPa |
0.25% |
| 211-D010K-3 |
0-10 kPa |
0.25% |
| 211-D025K-3 |
0-25 kPa |
0.25% |
| 211-D050K-3 |
0-50 kPa |
0.25% |
| 211-D100K-3 |
0-100 kPa |
0.25% |
*For 0-10 V OutPut, Add -V To The End Of The Part Number. Consult Factory For Other Calibration Ranges Including Zero Center RangesReliable Differential Pressure MonitoringThe Sensocon 211-D050K-3 offers dependable monitoring of pressure differences in complex environments. Its design ensures high-precision readings for both steam and gas, supporting demanding processes in diverse sectors. The advanced standard processing makes it suitable for facilities with rigorous operational requirements.
Adaptable Panel Mount DesignEngineered for streamlined integration, this transmitter's panel-mount configuration enables hassle-free installation within control systems. Its flexible finishes-including antique, polished, and matte-allow seamless adaptation to different site aesthetics and operational setups while maintaining a professional and robust appearance.
Wide Industry ApplicationsFrom hospitals and pharmaceutical manufacturing to power generation and textiles, the Sensocon USA 211-D050K-3 excels across industries. Its accuracy and versatility make it the preferred choice for organizations seeking reliable performance in processes demanding stringent control and monitoring.
FAQ's of Sensocon USA 211-D050K-3 Differential Pressure Transmitter From Kampagarh Kendrapara Orissa:
Q: How is the Sensocon 211-D050K-3 Differential Pressure Transmitter typically installed?
A: The transmitter is designed for panel mounting, which enables direct integration into control panels or enclosures. This setup streamlines wiring and enhances accessibility for monitoring and maintenance.
Q: What types of fluids or gases can this transmitter measure pressure for?
A: It is specifically engineered to measure the differential pressure of steam and gas. Its durability and construction also ensure reliable performance in various industrial fluid and gas applications.
Q: When should the Sensocon 211-D050K-3 be considered for use in your facility?
A: This model is ideal for use when accurate differential pressure measurement is critical, especially in environments such as hospitals, pharmaceuticals, power plants, and processing industries requiring stringent monitoring.
Q: Where is the Sensocon 211-D050K-3 primarily used?
A: This transmitter sees wide application in diverse fields, including pharmaceuticals, hotels, malls, hospitals, power and cement plants, steel and fertilizer plants, as well as the textile, food and beverage, and pulp and paper industries.
Q: What is the process for using and maintaining this pressure transmitter?
A: After installation, periodic calibration checks and visual inspections are recommended to ensure optimal performance. Maintenance procedures should follow industry standards, including routine verification of electrical connections and sensor cleanliness.
Q: What benefits does this differential pressure transmitter offer?
A: It delivers high-precision readings-accuracy up to 0.25%-helping improve process efficiency, safety, and compliance in controlled environments. Its robust build and flexible finish options further extend operational longevity and adaptability.