GEMTECH - Differential Pressure Gauges suppliers by Mysura KarnatakaSeries G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System.Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 (21 (3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)

FEATURES - OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS - Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model | Description |
| G2000-100MM | DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM | DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM | DPG,Range 0-150 MM W.C. |
| G2000-15MM | DPG,Range 0-15 MM W.C. |
| G2000-200MM | DPG,Range 0-200 MM W.C. |
| G2000-250MM | DPG,Range 0-250 MM W.C. |
| G2000-25MM | DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM | DPG,Range 0-300 MM W.C. |
| G2000-50MM | DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM | DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM | DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
Precision Engineering for Industrial NeedsBuilt with a 4-inch dial, GEMTECH Differential Pressure Gauges provide accurate pressure readings for critical applications. Ideal for steam, oil, or gas systems, its robust construction meets demanding requirements in power plants, hotels, hospitals, and manufacturing sectors. The analog display and aluminum pointer offer clarity and reliability.
Versatile Applications and Durable BuildDesigned for use across a spectrum of industries-from pharmaceuticals and food processing to textiles and steel plants-these gauges tolerate different environments. The metal alloy body, with multiple finishing options, ensures durability and resistance to wear and corrosion, making them suitable for both new installations and retrofits.
FAQ's of GEMTECH - Differential Pressure Gauges suppliers by Mysura Karnataka:
Q: How do I install the GEMTECH Differential Pressure Gauge on my system?
A: You can mount the GEMTECH gauge using its back mount design. Ensure the location allows easy visibility of the analog display, and connect it to your pressure line following standard procedures. Proper installation helps maintain accuracy and safety in operation.
Q: What media can the pressure gauge measure accurately?
A: This differential pressure gauge is engineered to measure the pressure of steam, oil, and gas. It performs reliably across these media, making it well-suited for use in pharmaceutical plants, hotels, hospitals, power and cement industries, among others.
Q: When should the gauge be calibrated for optimal accuracy?
A: For best accuracy (2% at 70F), calibration should be performed periodically, depending on the usage intensity or per your facility's maintenance schedule. Routinely check accuracy, especially if the gauge is used in critical environments such as pharmaceutical or food manufacturing.
Q: Where is this gauge most beneficial for use?
A: These gauges are most beneficial in industrial and commercial environments requiring precise pressure monitoring-such as power plants, cement factories, steel plants, textile mills, malls, and hospitals. Their durable build supports both robust and sensitive processes alike.
Q: What is the benefit of the plastic dial and metal alloy construction?
A: The plastic dial resists corrosion and impact, while the metal alloy body with various finishing options (antique, polished, galvanized, matte) ensures longevity and sustained performance, even in harsh or corrosive environments.
Q: How can the scale range options help me?
A: Multiple scale range options-including MM WC, CM, PAC, KPA, and INCH-allow you to select measurements in the units that best suit your process, simplifying interpretation and increasing operational efficiency.