Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION - Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70(21(3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES - OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa

PRODUCT APPLICATIONS - Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERINGGEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model | Description |
| G2000-100MM | DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM | DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM | DPG,Range 0-150 MM W.C. |
| G2000-15MM | DPG,Range 0-15 MM W.C. |
| G2000-200MM | DPG,Range 0-200 MM W.C. |
| G2000-250MM | DPG,Range 0-250 MM W.C. |
| G2000-25MM | DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM | DPG,Range 0-300 MM W.C. |
| G2000-50MM | DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM | DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM | DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
High-Accuracy Differential Pressure MeasurementGemtech Differential Pressure Gauges guarantee reliable accuracy with 2% of full span at 70 (21 (3% on -0, and 4% on -00). Engineered for sensitive environments, their measurement capabilities make them suitable for a wide range of industrial and commercial applications. The clear analog display and user-oriented design allow for seamless, on-site pressure readings, ensuring both performance and safety.
Versatile Applications Across IndustriesDesigned to accommodate the needs of various industries, these gauges can monitor pressure in steam, oil, and gas systems. Their usage spans pharmaceutical plants, hospitals, power facilities, malls, hotels, cement and steel plants, fertilizer production, textile, food and beverages, as well as pulp and paper industries. This versatility makes them a reliable solution for many pressure measurement requirements.
FAQ's of Gemtech Differential Pressure Gauges - Noida(UP):
Q: How do Gemtech Differential Pressure Gauges ensure accurate readings?
A: These gauges are calibrated to maintain an accuracy of 2% of the full span at 70 (with 3% on -0, and 4% on -00), providing precise measurement of pressure differentials across various applications.
Q: What is the primary use of these differential pressure gauges?
A: They are primarily used to measure pressure differences in steam, oil, or gas lines, ensuring system performance in industries like pharmaceuticals, power generation, healthcare, and manufacturing.
Q: When should these pressure gauges be installed or calibrated?
A: Installation is ideally carried out during system setup or maintenance stops, while calibration should be performed periodically, following manufacturer recommendations or industry regulations, to maintain accuracy.
Q: Where can these gauges be utilized effectively?
A: They are suitable for environments such as hospitals, pharmaceutical manufacturing units, hotels, malls, power, cement, and steel plants, as well as food and beverage and textile industries.
Q: What processes benefit the most from these gauges?
A: Processes that rely on constant monitoring of pressure differences-like filtration, ventilation, gas flow, and fluid control-benefit significantly from their reliable readings and robust build.
Q: How does the construction of the gauge enhance its performance?
A: The metal alloy body ensures durability, the back-mount design aids versatile installation, and finishes like antique, polished, galvanized, and matte offer added protection against environmental factors.