Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine,resistance of Filter,Wind Speed,Furnace Pressure,Differential Pressure Of Pore Plate,The Pressure of drum water level,Liquid Amplifier And Hydraulic Pressure System.Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION
- Ambient Temperature - -21 ~140 -6 ~60
- Rated Pressure -20 inHg~30 inHg (-68~103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel,with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - A2% of full span at 70 (21 (A3% on -0,and A4% on -00)
- Range -20 inHg~38 inHg (-68KPa~130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa

PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model |
Description |
| G2000-100MM |
DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
DPG,Range 0-150 MM W.C. |
| G2000-15MM |
DPG,Range 0-15 MM W.C. |
| G2000-200MM |
DPG,Range 0-200 MM W.C. |
| G2000-250MM |
DPG,Range 0-250 MM W.C. |
| G2000-25MM |
DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
DPG,Range 0-300 MM W.C. |
| G2000-50MM |
DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
Versatile Applications Across IndustriesGEMTECH Differential Pressure Gauges are designed for comprehensive use in industrial and commercial environments, including pharmaceuticals, hospitality, hospitals, malls, power plants, cement and steel industries, fertilizers, textile, food and beverage, and pulp and paper industries. Their robust construction and versatile measurement ranges make them an excellent choice for critical process monitoring.
Precision Engineering and Durable MaterialsThese gauges have a scale accuracy of 2% of full span (at 21C), ensuring reliable pressure readings. Made from quality stainless steel with available finishes such as antique, polished, galvanized, and matte, each unit is built to withstand demanding conditions. The solid aluminum pointer and plastic dial offer further durability and consistent performance.
User-Friendly Analog Display and Easy InstallationGEMTECH's analog display allows quick, clear reading of pressure values in multiple units (MM WC, CM, KPA, etc.), meeting diverse operational needs. The back mount type and standard 1/8" threading facilitate straightforward installation, minimizing downtime and enabling integration into existing systems. Weighing 550 grams, they are manageable and easy to handle during setup.
FAQ's of GEMTECH Differential Pressure Gauges Distributors for Dibai (UP):
Q: How can I install the GEMTECH Differential Pressure Gauge in my facility?
A: The GEMTECH gauge is designed for easy installation with a standard 1/8" thread and a back mount type. Simply secure the gauge into the corresponding threaded connection on your line and ensure it is tightened properly. If unsure, it's recommended to have a technician familiar with pressure systems complete the setup to ensure accurate readings.
Q: What pressure ranges can the gauge measure, and which substances is it compatible with?
A: This differential pressure gauge measures in a variety of scales, including MM WC, CM, PAC, KPA, INCH, and PSI, making it suitable for monitoring steam, oil, and gas. It ensures accurate readings with a 2% accuracy in most cases and is built for industrial-grade reliability.
Q: When should these gauges be used over digital alternatives?
A: Analog GEMTECH gauges are ideal where robust, immediate readings are needed without reliance on electronic components. They are particularly valuable in harsh environments or where electrical interference may be an issue, commonly found in factories, plants, or remote sites.
Q: Where can the GEMTECH Differential Pressure Gauge be utilized?
A: These gauges can be installed in a wide array of industries, including pharmaceuticals, hotels, malls, hospitals, operation theatres, power plants, cement plants, steel plants, fertilizer units, textile factories, the food and beverage sector, and the pulp and paper industry.
Q: What benefits does a stainless steel body and multiple finish options provide?
A: The stainless steel construction ensures strong resistance to corrosion and mechanical stress, extending service life. Finishing options like antique, polished, galvanized, and matte enable matching with specific project aesthetics or additional environmental protection.
Q: How do I maintain accuracy in pressure measurements over time?
A: Ensure regular calibration according to your facility's maintenance schedule. Keep the gauge clean, check for any mechanical damage, and verify that fittings are tight to avoid leaks or inaccuracies. If experiencing significant variation, professional recalibration may be necessary.
Q: What is the primary benefit of using a GEMTECH Differential Pressure Gauge?
A: The main advantage lies in its robust build, reliable analog measurement, and versatility across multiple substances and environments, supporting critical process control and safety monitoring in demanding industrial applications.