About GEMTECH DIFFERENTIAL PRESSURE GAUGE DISTRIBUTOR BY Chand Mohalla,Gandhi Nagar DELHI

GEMTECH DIFFERENTIAL PRESSURE GAUGE DISTRIBUTOR BY Chand Mohalla,Gandhi Nagar DELHI
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed,Furnace Pressure,Differential Pressure Of Pore Plate,The Pressure of drum water level,Liquid Amplifier And Hydraulic Pressure System.Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION
- Ambient Temperature -21 140 -6 60
- Rated Pressure-20 inHg30 inHg (-68103KPa)
- Overpressure-Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections-1/83 Female NPT Duplicate high and low pressure taps-one pair side and one pair back
- Housing-Die cast aluminum case and bezel,With acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy-2% of full span at 70(21(3% on -0,and 4% on -00)
- Range-20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered
FEATURES
OEM/ODM
- There Is No Need To Fill Liquid To Gauge
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed
- Exact And Stable Fixed Position Of Needle
- The Gauge Has Great Antiknock Characteristics
- There Are 81 Types Of Ranges.
- Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
GEMTECH By Model Number Popularity
FILTER BY
Range Kilopascals
| Model |
Description |
| G2000-1KPA |
GEMTECH DIFFERENTIAL PRESSURE GAUGE,Range 0-1 kPa,Minor Divisions .02 |
| G2000-1.5KPA |
GEMTECH DIFFERENTIAL PRESSURE GAUGE,Range 0-1.5 kPa,Minor Divisions .05 |
| G2000-2KPA |
GEMTECH DIFFERENTIAL PRESSURE GAUGE,Range 0-2 kPa,Minor Divisions .05 |
| G2000-3KPA |
GEMTECH DIFFERENTIAL PRESSURE GAUGE, Range 0-3 kPa,Minor Divisions.10 |
| G2000-4KPA |
GEMTECH DIFFERENTIAL PRESSURE GAUGE,Range 0-4 kPa,Minor Divisions.10 |
| G2000-5KPA |
GEMTECH DIFFERENTIAL PRESSURE GAUGE,Range 0-5 kPa,Minor Divisions.10 |
| G2000-8KPA |
GEMTECH DIFFERENTIAL PRESSURE GAUGE,Range 0-8 kPa,Minor Divisions.20 |
| G2000-10KPA |
GEMTECH DIFFERENTIAL PRESSURE GAUGE,Range 0-10 kPa,Minor Divisions .20 |
| G2000-15KPA |
GEMTECH DIFFERENTIAL PRESSURE GAUGE,Range 0-15 kPa,Minor Divisions .50 |
| G2000-20KPA |
GEMTECH DIFFERENTIAL PRESSURE GAUGE,Range 0-20 kPa,Minor Divisions .50 |
| G2000-25KPA |
GEMTECH DIFFERENTIAL PRESSURE GAUGE,Range 0-25 kPa,Minor Divisions .50 |
| G2000-30KPA |
GEMTECH DIFFERENTIAL PRESSURE GAUGE,Range 0-30 kPa,Minor Divisions 1.0 |
Additional Information:
- Item Code: GEMTECH DIFFERENTIAL PRESSURE GAUGE DISTRIBUTOR BY Chand Mohalla,Gandhi Nagar DELHI
- E-mail :
dpsharma74@yahoo.co.in,
dpsharma1974@gmail.com,
dpsharma949@gmail.com
Mr D.P.SHARMA 9871014210
WhatsApp number :9871014210,9268631221
Websites :
www.dpengineers.in,
www.dpengineer.in,
www.dpengineers.co.in,
www.dpengineer.co.in,
www.dpengineersindia.com,
www.dpengineerindia.com,
www.dpengineersindia.in,
- WhatsApp No.9871014210,WhatsApp No.9811065204,WhatsApp No.8376899729,WhatsApp No.8368888047,WhatsApp No.9268631221,

Versatile Pressure MeasurementGEMTECH Differential Pressure Gauge offers comprehensive pressure measurement for a wide spectrum of industries from pharmaceuticals to power plants. With multiple scale range options and robust materials, it's engineered for precise and steady performance in critical environments.
Durable Design and ConstructionConstructed with stainless steel material and finished with options such as antique, polished, galvanized, and matte, this 4-inch gauge ensures longevity and resistance to challenging working conditions. Its plastic dial and aluminum pointer add to its reliability and ease of use.
User-friendly Installation and AccuracyDesigned for panel mounting, the gauge features a 1/8 inch BSP thread, making installation straightforward. Its analog display is easily visible, and with 2% accuracy, users can rely on its precise readings for critical operations across various sectors.
FAQ's of GEMTECH DIFFERENTIAL PRESSURE GAUGE DISTRIBUTOR BY Chand Mohalla,Gandhi Nagar DELHI:
Q: How is the GEMTECH Differential Pressure Gauge installed?
A: The gauge is designed for panel mounting and comes with a 1/8 inch BSP thread, allowing for secure, straightforward installation in control panels across industrial settings.
Q: What media can this differential pressure gauge measure?
A: It is suited for measuring the pressure of steam and gases, making it ideal for environments like hospitals, pharmaceutical manufacturing, power plants, cement, and textile industries.
Q: Where can the GEMTECH Differential Pressure Gauge be used?
A: It is widely used in pharmaceutical, food and beverage, pulp and paper, textiles, hotels, malls, hospitals, and heavy industry sectors such as steel and cement plants to monitor and control critical pressures.
Q: What is the accuracy level of this pressure gauge?
A: This gauge provides an accuracy of 2%, ensuring reliable measurements for process control and safety in demanding environments.
Q: What finishing options are available for this gauge?
A: The gauge is available in several finish types including antique, polished, galvanized, and matte, providing both functional durability and aesthetic appeal.
Q: What are the benefits of using an analog display with this gauge?
A: The analog display offers immediate, clear readings, minimizing the risk of digital errors and making it easy for operators to monitor pressure changes at a glance, especially in fast-paced industrial settings.