About GEMTECH Differential Pressure Gauge By Selaqui Dehradun Uttarakhand
GEMTECH Differential Pressure Gauge By Selaqui Dehradun UttarakhandSeries G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION
- Ambient Temperature - -21 ~140 -6 ~60
- Rated Pressure -20 inHg~30 inHg (-68~103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - A2% of full span at 70 (21 (A3% on -0, and A4% on -00)
- Range -20 inHg~38 inHg (-68KPa~130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERINGGEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model |
Description |
| G2000-100MM |
DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
DPG,Range 0-150 MM W.C. |
| G2000-15MM |
DPG,Range 0-15 MM W.C. |
| G2000-200MM |
DPG,Range 0-200 MM W.C. |
| G2000-250MM |
DPG,Range 0-250 MM W.C. |
| G2000-25MM |
DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
DPG,Range 0-300 MM W.C. |
| G2000-50MM |
DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
DPG,Range 0-80 MM W.C., Minor Divisions 2.0.
|
Versatile Applications Across IndustriesEngineered for diverse environments, this differential pressure gauge is ideal for pharmaceutical plants, hotels, hospitals, cement and steel plants, and many other sectors. Its rugged construction and adaptability make it a reliable choice for professionals seeking accurate pressure monitoring in steam, oil, or gas systems across different industries.
Precision and Durability CombinedFeaturing an analog display for real-time readings, the GEMTECH gauge boasts high accuracy and a robust metal alloy build. The back-mount design and various finishes-antique, polished, galvanized, and matte-provide both longevity and visual appeal. The plastic dial and aluminum pointer add to its lightweight yet durable construction.
FAQ's of GEMTECH Differential Pressure Gauge By Selaqui Dehradun Uttarakhand:
Q: How is the GEMTECH Differential Pressure Gauge installed and where can it be mounted?
A: The GEMTECH gauge is designed with a back mount, enabling easy installation on control panels, walls, or equipment surfaces. It is commonly used in industrial settings such as hospitals, power plants, and manufacturing units for continuous pressure monitoring.
Q: What is the process for using this gauge to measure pressure in different applications?
A: To measure differential pressure, connect the gauge's inlet ports to the respective points within your steam, oil, or gas system. Once installed, the analog dial will provide real-time, accurate readings within its specified scale range, ensuring safe and efficient monitoring.
Q: What are the benefits of using the GEMTECH Differential Pressure Gauge in industrial environments?
A: Benefits include high accuracy (2% of full span), sturdy construction using metal alloy, resistance to demanding conditions, and the flexibility to measure a wide range of pressures in MM WC, KPA, CM, PAC, and INCH. Its analog display allows for straightforward interpretation in critical operations.
Q: When should this differential pressure gauge be calibrated or maintained?
A: To maintain accuracy, calibration should be performed at regular intervals as specified by industry standards or manufacturer recommendations, especially after exposure to severe pressure fluctuations or environmental changes.
Q: What safety considerations should be followed during gauge operation?
A: Ensure the gauge is properly installed and serves within its rated pressure range. Avoid exceeding limits to prevent mechanical damage and periodically inspect for leaks or physical wear to guarantee consistent performance and workplace safety.
Q: In which settings is this pressure gauge most commonly used?
A: The GEMTECH gauge is widely used in pharmaceutical manufacturing, hospitals, hotels, cement and steel plants, fertilizer production, textile industries, food and beverage processing, as well as the pulp and paper industry.