About GEMTECH Differential Pressure Gauge By Bagalkote Mahalingapur
GEMTECH Differential Pressure Gauge By Bagalkote MahalingapurSeries G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70(21(3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERINGGEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model |
Description |
| G2000-100MM |
DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
DPG,Range 0-150 MM W.C. |
| G2000-15MM |
DPG,Range 0-15 MM W.C. |
| G2000-200MM |
DPG,Range 0-200 MM W.C. |
| G2000-250MM |
DPG,Range 0-250 MM W.C. |
| G2000-25MM |
DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
DPG,Range 0-300 MM W.C. |
| G2000-50MM |
DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
DPG,Range 0-80 MM W.C., Minor Divisions 2.0.
|
Reliable Performance Across Industries
Engineered for use in critical sectors such as pharmaceuticals, hospitals, power plants, and manufacturing, the GEMTECH Differential Pressure Gauge ensures accurate and dependable pressure measurements. Its sturdy metal alloy body and advanced finishes withstand demanding environments, bringing reliability to both industrial and commercial facilities.
Precision in Measurement
With an accuracy of 2% at 70F, this analog gauge delivers trustworthy readings for processes involving steam, oil, and gas. The gauge's robust design, combined with a clear 4-inch dial and aluminum pointer, enables easy monitoring-critical for maintaining safety and process control across industries like food and beverages, pulp and paper, and textile.
FAQ's of GEMTECH Differential Pressure Gauge By Bagalkote Mahalingapur:
Q: How does the GEMTECH Differential Pressure Gauge ensure accuracy in industrial applications?
A: The gauge provides precise measurements with 2% accuracy at 70F, thanks to its high-quality metal alloy construction and finely calibrated analog display. This accuracy supports reliable monitoring in industries such as pharmaceuticals, power, and manufacturing, where consistent pressure is crucial.
Q: What is the typical process for installing this differential pressure gauge?
A: Installation is straightforward due to its back mount type and compact 4-inch diameter. The gauge is designed for standard processing environments and can be securely fitted onto pipelines or panels where differential pressure monitoring of steam, oil, or gas is required.
Q: Where can the GEMTECH Differential Pressure Gauge be used?
A: This gauge is widely applicable in places such as hospitals, pharmaceutical manufacturing, power and cement plants, shopping malls, hotels, steel plants, and the food and beverage industry. Its versatile design meets the diverse monitoring needs of both industrial and commercial settings.
Q: What are the benefits of using this pressure gauge in operational settings?
A: Utilizing this gauge enhances process safety by providing reliable pressure readings. Its robust build, varied finishing options, and high accuracy help reduce downtime and maintenance costs in complex operational environments.
Q: How should the gauge be maintained to ensure long-term usability?
A: Regular inspection for physical damage, adherence to recommended cleaning routines, and periodic recalibration will sustain the accuracy and performance of the device. The durable metal alloy construction and robust finishing options support long-term reliability with minimal upkeep.
Q: What materials are used in the construction of this gauge, and how do they benefit performance?
A: The gauge is constructed from a sturdy metal alloy, with finishes including antique, polished, galvanized, and matte. The pointer is made from aluminum and the dial from plastic, ensuring longevity, resistance to corrosion, and clear readability even in harsh environments.