About GEMTECH DESH KA NUMBER 1 DIFFERENTIAL PRESSURE GAUGE
GEMTECH DESH KA NUMBER 1 DIFFERENTIAL PRESSURE GAUGE
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine,resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System.Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION
- Ambient Temperature - -21 ~140 -6 ~60
- Rated Pressure -20 inHg~30 inHg (-68~103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - A2% of full span at 70(21(A3% on -0, and A4% on -00)
- Range -20 inHg~38 inHg (-68KPa~130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERINGGEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model |
Description |
| G2000-100MM |
DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
DPG,Range 0-150 MM W.C. |
| G2000-15MM |
DPG,Range 0-15 MM W.C. |
| G2000-200MM |
DPG,Range 0-200 MM W.C. |
| G2000-250MM |
DPG,Range 0-250 MM W.C. |
| G2000-25MM |
DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
DPG,Range 0-300 MM W.C. |
| G2000-50MM |
DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
Versatile Industrial ApplicationsEngineered to excel in challenging environments, the GEMTECH Differential Pressure Gauge serves key roles in sugar, steel, paper, and cement industries. Its accuracy, durability, and compatibility across a variety of process conditions offer significant operational benefits to both end users and distributors.
Comprehensive Measurement OptionsWith multi-unit scale ranges including MM WC, CM, KPA, INCH, PSI, and MBAR, this gauge supports precise monitoring across a wide spectrum of pressure values. The analog display, robust stainless steel construction, and quality finishes ensure lasting performance and easy readability.
FAQ's of GEMTECH DESH KA NUMBER 1 DIFFERENTIAL PRESSURE GAUGE:
Q: How does the GEMTECH Differential Pressure Gauge work?
A: This gauge measures the difference in pressure between two points, displaying the value from a wide range of engineering units on a clear glass analog dial. It is suitable for applications involving steam and gas.
Q: What industries typically use this gauge?
A: Sugar mills, steel plants, paper mills, and cement factories often employ this gauge due to its broad range of measurement units and durable stainless steel design.
Q: When should I consider replacing or recalibrating the gauge?
A: Routine recalibration should be performed based on usage frequency and industry standards, typically once a year or if accuracy falls outside the 2% tolerance. Replacement may be needed if the dial, pointer, or seal is damaged.
Q: Where is the GEMTECH Differential Pressure Gauge installed?
A: The gauge is typically back-mounted using its 1/8 thread, allowing installation on panels or directly onto pipelines, near points where pressure differentials need monitoring.
Q: What is the process for installing this gauge?
A: Ensure all connections match the 1/8 thread specification. Mount the gauge securely on the desired surface, connect the pressure lines for inlets and outlets, and verify the display accuracy post-installation.
Q: How does using this gauge benefit industrial operations?
A: Accurate differential pressure measurement helps maintain operational efficiency, detect leaks, and ensure safety, contributing to optimized process control and reduced downtime.