Back to top
Fan Blower
Fan Blower

Fan Blower

Fan Blower Specification

  • Max Pressure
  • 500 mmAq
  • Output Power
  • 0.75 kW
  • Flow Rate
  • 600 m3/h
  • Life Span
  • 8-10 Years
  • Pressure Range
  • 200-500 mmAq
  • Motor Power
  • 0.75 kW
  • Power
  • 1 HP
  • Product Type
  • Fan Blower
  • Material
  • Metal
  • Capacity
  • 600 CFM
  • Pressure
  • 370 mmAq
  • Application
  • Industrial Cooling and Air Conditioning
  • Frequency (MHz)
  • 50 Hz
  • Motor Speed
  • 2800 RPM
  • Noise Level
  • Below 75 dB
  • Power Source
  • Electric
  • Voltage
  • 220-240 V
  • Weight
  • 18 kg
  • Dimension (L*W*H)
  • 400 x 250 x 350 mm
  • Color
  • Silver
  • Enclosure
  • TEFC
  • Mounting Type
  • Base Mounted
  • Impeller Type
  • Backward Curved
  • Air Flow Direction
  • Forward Curved Discharge
  • Inlet Size
  • 100 mm
  • Bearings
  • Sealed Ball Bearing
  • Finish
  • Powder Coated
  • Insulation Class
  • Class F
  • Number of Stages
  • Single Stage
  • Operating Temperature Range
  • -10C to 60C
 
 

About Fan Blower

Fan Blower

We offer DWDI FC Blower/Fan, Impeller. For fabricating these impellers, we use best quality mild steel to ensure their high durability. We manufacture them keeping into consideration the set industrial benchmarks. These impellers offer hassle free service consuming less time. Further, we offer customization facility to suit clients' demands perfectly.

Specifications:

  • Sizes: 150 mm to 2,500 mm
  • Material: Al., MS,GI


Other Information

  • Pay Mode Terms: T/T (Bank Transfer)


High-Efficiency Performance

Engineered for industrial cooling and air conditioning, this fan blower delivers a powerful flow rate of 600 m3/h at pressures up to 500 mmAq. Its backward curved impeller generalizes stable airflow while maintaining efficiency and reliability, even in demanding environments. The unit operates quietly, ensuring comfort in noise-sensitive settings.


Durable and Low-Maintenance Design

Constructed from high-quality metal with a silver powder-coated finish, this blower endures rigorous use. Sealed ball bearings and a TEFC enclosure safeguard against dust and debris, reducing wear and prolonging the blower's lifespan to 8-10 years. Minimal maintenance is required, making it ideal for round-the-clock industrial operations.


Versatile Industrial Applications

Ideal for a wide range of industrial scenarios, this base-mounted blower supports applications in HVAC systems, manufacturing plants, and process cooling. Its compact dimensions (400 x 250 x 350 mm) and manageable weight (18 kg) allow for easy installation in constrained spaces while providing powerful, reliable airflow wherever needed.

FAQ's of Fan Blower:


Q: How is the fan blower installed, and what are its mounting requirements?

A: This fan blower is base-mounted, making installation straightforward on stable, flat surfaces. Ensure proper alignment and secure all fastenings for optimal performance and minimal vibration. Electrical connections should comply with local standards and be handled by qualified personnel.

Q: What operating conditions is this blower suitable for?

A: Designed for industrial environments, the blower operates effectively in temperatures from -10C to 60C and can withstand demanding conditions due to its IP-protected TEFC enclosure and powder-coated metal construction.

Q: When should maintenance be performed on this blower?

A: Thanks to its sealed ball bearings and durable construction, the blower requires minimal maintenance. Periodic checks for dust buildup and regular inspection of the electrical system are recommended, but lubricant servicing of bearings is generally not needed.

Q: Where can this blower be used within industrial facilities?

A: This blower is suitable for installation in cooling and HVAC systems, manufacturing lines, and areas where controlled air flow and low noise levels are essential. Its compact design allows it to fit easily into various machinery or ventilation layouts.

Q: What benefits does the backward curved impeller provide?

A: A backward curved impeller enhances efficiency by reducing air resistance, enabling the blower to deliver a consistent and powerful airflow at reduced energy consumption, while also minimizing wear and noise.

Q: How does the blower contribute to a safe and comfortable work environment?

A: With a noise level below 75 dB and a totally enclosed, fan-cooled motor, the blower ensures quiet operation and protected components, minimizing disturbances and promoting a safer environment for workers.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Centrifugal Blower Category

Furnace Burner Blower

Furnace Burner Blower

Power Source : Other, Electric

Product Type : Others, Furnace Burner Blower

Application : Other, Industrial heating furnace applications

Frequency (MHz) : 50 MHz

Belt Driven Centrifugal Fan

Belt Driven Centrifugal Fan

Power Source : Other, AC power

Product Type : Belt Driven Centrifugal Fan, Others

Application : Other, Industrial ventilation

Frequency (MHz) : 50 60 Hz

Blower Exhaust System

Blower Exhaust System

Power Source : Electric, Other

Product Type : Blower Exhaust System, Others

Application : Other, Industrial Ventilation

Frequency (MHz) : 50 Hz

Direct Driven Fan 10 Inch X 10 Inch

Direct Driven Fan 10 Inch X 10 Inch

Price 18500 INR

Minimum Order Quantity : 5 Pieces

Power Source : Electric Blower

Product Type : Exhaust Air Blower, Others

Application : Industrial

Frequency (MHz) : 50/60 Hertz(Hz)