Back to top
Dwyer USA Magnehelic Gauges 0 To 40 Inch WC
Dwyer USA Magnehelic Gauges 0 To 40 Inch WC

Dwyer USA Magnehelic Gauges 0 To 40 Inch WC

MOQ : 25 Pieces

Dwyer USA Magnehelic Gauges 0 To 40 Inch WC Specification

  • Bourdon Tube
  • Not Applicable (Diaphragm Sensing Element)
  • Seal Material
  • Silicone Rubber
  • Grade
  • Industrial
  • Sensor Type
  • Differential Pressure
  • Thread
  • 1/8 NPT Female
  • Display
  • Analog
  • Outer Size
  • Approx. 4 inch (101.6 mm) diameter housing
  • Material
  • Die-cast Aluminum Case, Acrylic Lens
  • Dial Material
  • Acrylic
  • Pointer Material
  • Aluminum
  • Processing Type
  • Precision-Machined
  • Diameter
  • Approx. 4 inches (101.6 mm)
  • Glass Size
  • 4 inches
  • Mount Type
  • Surface or Flush Mount
  • Scale Range
  • 0 to 40 inch WC (Water Column)
  • Accuracy
  • 2% of Full Scale
  • Accessories
  • Two 1/8 NPT plugs, two compression fittings for 1/4 OD tubing, and mounting screws
  • Port Connection
  • 1/8" NPT Female both High and Low Pressure
  • Model Series
  • Dwyer Magnehelic Gauge 2000 Series
  • Application
  • Filter monitoring, Clean room pressure, Fan and blower pressure, Duct static pressure
  • Weight
  • Approx. 470 grams
  • Operating Temperature
  • -7C to 60C (20F to 140F)
  • Overpressure Limit
  • 15 psi (1.03 bar)
  • Zero Adjustment
  • External Adjustment Screw
 

Dwyer USA Magnehelic Gauges 0 To 40 Inch WC Trade Information

  • Minimum Order Quantity
  • 25 Pieces
  • FOB Port
  • Delhi
  • Payment Terms
  • Cash Against Delivery (CAD), Cash in Advance (CID), Cash Advance (CA), Paypal, Cash on Delivery (COD)
  • Supply Ability
  • 1 Piece Per Day
  • Delivery Time
  • 1 Days
  • Sample Available
  • No
  • Main Export Market(s)
  • Middle East, Asia
  • Main Domestic Market
  • All India
 

About Dwyer USA Magnehelic Gauges 0 To 40 Inch WC

Dwyer USA Magnehelic Gauges 0 To 40 Inch WC


 Model Description 
 2040Differential pressure gage, range 0-40" w.c., minor divisions 1.0. 

 The industry standard in indicating low air or gas pressures of positive, negative, or differential pressures.

Large, easy-to-read 4" (102 mm) dial.

No manometer fluid to evaporate, freeze, or cause toxic or leveling problems.

INCLUDES

Two 1/8" NPT plugs, two 1/8" rubber tubing adapters, and three mounting adapters with screws

MORE ABOUT THIS ITEM

The Magnahelic guage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems, and pressures in fluid amplifier or fluidic systems. The gauge's motion is damped with high-viscosity silicone fluid. The zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness. Rugged design resists shock, vibration, and overpressure.

The helix is precision-made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the maganetic field to move the pointer across the scale. The samarium cobalt magnet is mounted at one end of the range spring and rotates the helix without mechanical linkages. 

Specifications & Description 

 

 
 Accuracy±3% full-scale 
 Dial Size (in)
 Dial Size (mm)102 
 Min Pressure (in WC)
 Max Pressure (in WC)0.5 
 Min Temperature (° F)20 
 Max Temperature (° F)140 
 Min Temperature (° C) 7
 Max Temperature (° C)60 
Liquid FillSilicone 
CaseAluminum 
 Lens MaterialPolycarbonate
 Process Connection1/8" NPT(F)
 Unit Of Measurement " WC
 Displayanalog dial
 Media CompatibilityAir and noncombustible, compatible gases 
 DescriptionMagnehelic Differential Pressure Gauge,  20400-40" w.c


Versatile Pressure Measurement

The Dwyer Magnehelic Gauge 2000 Series is engineered for precise differential pressure monitoring across multiple industrial applications. Its robust construction and comprehensive mounting options make it suitable for installations in HVAC systems, clean rooms, and process industries.


Rugged and Accurate Design

Constructed with a die-cast aluminum case and an acrylic lens, the gauge delivers durability and consistent performance. The diaphragm sensing element provides accuracy within 2% of the full scale, supporting high reliability even in demanding monitoring scenarios.


User-Friendly Installation and Adjustment

Featuring an external zero adjustment screw and versatile mounting positions (surface or flush mount), the gauge ensures quick setup and recalibration. Complete accessory fittings, including compression connectors and mounting screws, simplify the installation process.

FAQ's of Dwyer USA Magnehelic Gauges 0 To 40 Inch WC:


Q: How do I adjust the zero point on the Dwyer Magnehelic Gauge 2000 Series?

A: The zero adjustment can be made externally using the adjustment screw located on the front bezel of the gauge. This allows for easy recalibration without disassembling the unit.

Q: What types of pressure media can this gauge safely measure?

A: The Dwyer Magnehelic Gauge 2000 Series is suitable for measuring the differential pressure of steam, oil, and gas, making it appropriate for a variety of industrial environments.

Q: When should a Magnehelic Gauge be used for filter monitoring or cleanroom pressure applications?

A: Use the gauge whenever it's critical to monitor and maintain specific pressure differentials, such as in HVAC filter monitoring, clean rooms for contamination control, or ducts to ensure proper air flow.

Q: Where can the gauge be mounted, and what are the mounting options?

A: The gauge offers both surface and flush mount options, permitting flexible placement on panels, walls, or dedicated enclosures as required by your application.

Q: What is the process for connecting the gauge to my existing system?

A: Connect the 1/8" NPT female ports (high and low) to your pressure source using the provided NPT plugs or compression fittings for 1/4" OD tubing, securing the unit with the supplied mounting screws.

Q: What are the primary benefits of using a Dwyer Magnehelic Gauge in industrial settings?

A: The gauge provides quick, accurate differential pressure readings crucial for equipment efficiency and safety. Its robust design withstands rigorous use, while precision-machined components minimize maintenance and downtime.

Q: How does the diaphragm sensing element enhance measurement reliability?

A: The diaphragm sensing element, unlike Bourdon tubes, responds sensitively to pressure differences, ensuring stable and precise analog readouts over the wide scale of 0 to 40 inches WC.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Dwyer Magnehelic Gauges Series 2000 - D.P.ENGINEER Category

Dwyer Make Magnehellic Pressure Gauges

Dwyer Make Magnehellic Pressure Gauges

Price 4100 INR

Minimum Order Quantity : 25 Pieces

Accuracy : 2% of full scale

Display : Analog

Pointer Material : Plastic

Thread : 1/8 NPT Female

CATEGORY Leader Dwyer Magnehelic Differential Pressure Gauge -D.P.ENGINEERS

CATEGORY Leader Dwyer Magnehelic Differential Pressure Gauge -D.P.ENGINEERS

Price 8500 INR / Piece

Minimum Order Quantity : 25 Pieces

Accuracy : 2% of full span at 70 (21 (3% on 0, and 4% on 00) %

Display : Analog

Pointer Material : Aluminum

Thread : 1/8" female NPT duplicate high and low pressure taps one pair side and one pair back

Dwyer USA Magnehelic Gauges 0 To 150 Inch WC

Dwyer USA Magnehelic Gauges 0 To 150 Inch WC

Minimum Order Quantity : 25 Pieces

Accuracy : 2% of Full Scale

Display : Analog

Pointer Material : Other, Red Taut Band

Thread : 1/8 NPT Female

Dwyer USA Model 2160 Magnehelic Gage Range 0-160 Inch WC

Dwyer USA Model 2160 Magnehelic Gage Range 0-160 Inch WC

Minimum Order Quantity : 25 Pieces

Accuracy : 2% of Full Scale

Display : Analog

Pointer Material : Other, Red Plastic

Thread : 1/8 NPT Female (High & Low Pressure Ports)