Dwyer A3215 Photohelic Pressure Switch Gauge Specification

  • Material
  • Metal Alloy
  • Usage
  • Air Conditioner Systems Clean Rooms Fume Exhaust Systems
  • Dial Material
  • Plastic
  • Pointer Material
  • Aluminum
  • Processing Type
  • Standard
  • Diameter
  • 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm) Millimeter (mm)
  • Product Type
  • Dwyer A3215 Photohelic Pressure Switch Gauge Range 0-15 psi
  • Glass Size
  • 4"
  • Weight
  • 4 lb (1.81 kg) Kilograms (kg)
  • Mount Type
  • Panel
  • Color
  • Black
  • Scale Range
  • Range 0-15 psi
  • Accuracy
  • 2% of FS at 70F (21.1C),3% on -0,4% on -00 models mm
 

Dwyer A3215 Photohelic Pressure Switch Gauge Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • FOB Port
  • Delhi
  • Payment Terms
  • Cash in Advance (CID), Cash Advance (CA), Cash Against Delivery (CAD), Cash on Delivery (COD)
  • Supply Ability
  • 5 Pieces Per Week
  • Delivery Time
  • 5-6 Week
  • Main Export Market(s)
  • Middle East, Asia
  • Main Domestic Market
  • All India
 

About Dwyer A3215 Photohelic Pressure Switch Gauge

Dwyer A3215 Photohelic Pressure Switch Gauge Range 0-15 psi

Dwyer A3215 Photohelic Pressure Switch/Gauge (0-15 psi)

Model: A3215

Bezel and front cover (with set point knobs and zero adjustment screw) removed to expose Photohelic switch/gage set point mechanism. Cover is clear polycarbonate plastic. Gage pointer and light shutter are mounted on helix and balancing counterweight.

Dwyer A3215 Offers

Features

  • Measure 4 to 20 mA signals without "breaking the loop"
  • Measure mA signals for PLC and control system analog I/O
  • Dual backlit display with both mA measurement and percent of 4 to 20 mA span
  • Measurement Spotlight illuminates hard to see wires in dark enclosures
  • Detachable clamp with extension cable for measurements in tight locations
  • Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
  • Automatically change the 4 to 20 mA output for remote testing
  • Power saving features,auto-off, backlight timeout extend battery life
  • Hold function captures and displays changing measurements

Applications

  • Air Conditioner Systems
  • Clean Rooms
  • Fume Exhaust Systems
  • Dwyer A3215 Specifications

Switch Specifications

  • Switch Type:Each set point has 2 Form C relays (DPDT)
  • Repeatability:±1% of FS
  • Electrical Rating:10 A at 28 VDC,10 A at 120,240 VAC
  • Electrical Connections:Screw terminals.Use 167°F (75°C) copper conductors only
  • Power Requirements:120 VAC, 50/60 Hz,240 VAC and 24 VAC power optional
  • Mounting Orientation:Diaphragm in vertical position. Consult factory for other position orientations
  • Set Point Adjustment:Adjustable knobs on face
  • Agency Approvals:CE, CSA, UL

Gauge Specifications

  • Service:Air and non-combustible, compatible gases
  • Accuracy:±2% of FS at 70°F (21.1°C)±3% on -0±4% on -00 models
  • Pressure Limits:-20" Hg to 25 psig (-0.677 to 1.72 bar),MP option; 35 psig (2.41 bar),HP option; 80 psig (5.52 bar)
  • Temperature Limits:20 to 120°F. (-6.67 to 48.9°C),-20 to 120°F (-28 to 48.9°C) with low temperature option
  • Process Connections: female NPT
  • Dimensions:4" (101.6 mm) dial face,5 x 8¼" (127 x 209.55 mm)
  • Weight:4 lb (1.81 kg)



Versatile Performance for Demanding Environments

Built to excel in environments requiring precise pressure management, the Dwyer A3215 adapts seamlessly across air conditioning systems, clean rooms, and fume extraction setups. Its sturdy construction and multiple finish options ensure both durability and aesthetic flexibility, fitting a variety of industrial settings with ease.


Exceptional Accuracy and Functional Design

The gauge delivers accuracy within 2% of full scale at standard conditions, ensuring reliable readings. The 4-inch dial, black color, and clear plastic face promote easy measurement, while the panel mount design supports straightforward installation. Lightweight yet robust at 4 lbs (1.81 kg), it is engineered for consistent, long-term use.

FAQ's of Dwyer A3215 Photohelic Pressure Switch Gauge:


Q: How is the Dwyer A3215 Photohelic Pressure Switch Gauge installed?

A: The Dwyer A3215 is designed for panel mounting, making it easy to integrate into control panels or system enclosures in industrial environments. Mounting instructions are provided in the product manual for secure and optimal installation.

Q: What types of media can this gauge measure?

A: This gauge is suitable for measuring the pressure of steam, oil, and gas, offering versatility across a spectrum of industrial applications such as HVAC, clean room monitoring, and fume exhaust systems.

Q: When should the gauge be recalibrated to maintain accurate readings?

A: It is recommended to recalibrate the gauge periodically, typically annually or according to your application's maintenance schedule, to ensure it maintains its 2% full scale accuracy, especially when used in critical environments.

Q: Where is the Dwyer A3215 Photohelic Pressure Switch Gauge commonly used?

A: Common applications include air conditioning systems, clean rooms, and fume extraction systems. It is widely used by exporters, manufacturers, suppliers, and traders in the industrial sector, particularly in India.

Q: What benefits does the gauge's metal alloy construction provide?

A: The metal alloy construction enhances durability and longevity, ensuring the gauge withstands demanding industrial environments. The variety of finishes, like matte and galvanized, also provide additional resistance to corrosion and wear.

Q: How does the accuracy of the gauge impact its performance?

A: With an accuracy of 2% of full scale at 70F, the Dwyer A3215 ensures that pressure measurements are reliable, reducing the risk of error in sensitive or safety-critical systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series A3000 Photohelic Pressure Switch/Gage Category

Dwyer A3000-3KPA Photohelic Pressure Switch Gauge

Dwyer A3000-3KPA Photohelic Pressure Switch Gauge

Price 45000 INR / Piece

Minimum Order Quantity : 5 Pieces

Product Type : Photohelic Pressure Switch Gauge Range 03 kPa.

Material : Metal Alloy

Diameter : 4"(101.6 mm) dial face,5 x 8"(127 x 209.55 mm) Inch (in)

Usage : Air and Non Combustible,Compatible Gases

Dwyer A3001AV Photohelic Pressure Switch Gauge

Dwyer A3001AV Photohelic Pressure Switch Gauge

Price 45000 INR / Piece

Minimum Order Quantity : 5 Pieces

Product Type : Dwyer A3001AV Photohelic Pressure Switch Gauge Range 01.0 Inch w.c.5004000 FPM

Material : Metal Alloy

Diameter : 4"(101.6 mm) dial face,5 x 8"(127 x 209.55 mm) Inch (in)

Usage : Air and noncombustible,compatible gases

Dwyer A3220 Photohelic Pressure Switch Gauge

Dwyer A3220 Photohelic Pressure Switch Gauge

Price 45000 INR / Piece

Minimum Order Quantity : 5 Pieces

Product Type : Photohelic Pressure Switch Gauge Range 020 psi

Material : Metal Alloy

Diameter : 4" (101.6 mm) dial face,5 x 8" (127 x 209.55 mm) Millimeter (mm)

Usage : Air Conditioner Systems Clean Rooms Fume Exhaust Systems

Dwyer A3204 Photohelic Pressure Switch Gauge

Dwyer A3204 Photohelic Pressure Switch Gauge

Price 45000.00 INR / Piece

Minimum Order Quantity : 5 Pieces

Product Type : Photohelic Pressure Switch Gauge

Material : Metal Alloy

Diameter : 4"(101.6 mm) dial face,5 x 8" (127 x 209.55 mm) Millimeter (mm)

Usage : Air Conditioner Systems Clean Rooms Fume Exhaust Systems