Back to top
Dwyer 3050MRS Photohelic Switch/Gauge 0 to 50 inch
Dwyer 3050MRS Photohelic Switch/Gauge 0 to 50 inch

Dwyer 3050MRS Photohelic Switch/Gauge 0 to 50 inch

Dwyer 3050MRS Photohelic Switch/Gauge 0 to 50 inch Specification

  • Seal Material
  • Silicone Rubber
  • Outer Size
  • 4 Inch (101 mm) Dial Face
  • Thread
  • 1/8 NPT Female High and Low Pressure Connections
  • Sensor Type
  • Differential Pressure Sensor
  • Display
  • Analog with Switch Indicators
  • Grade
  • Industrial Grade
  • Material
  • Die-cast Aluminum Housing
  • Dial Material
  • Acrylic
  • Pointer Material
  • Aluminum
  • Processing Type
  • Precision Engineering
  • Diameter
  • 4 Inch
  • Glass Size
  • 4 Inch
  • Mount Type
  • Panel Mount or Surface Mount
  • Scale Range
  • 0 to 50 inch w.c. (Water Column)
  • Accuracy
  • 2% of Full Scale
  • Accessories
  • Mounting Hardware and Installation Manual
  • Pressure Limits
  • 30 psi (2.07 bar) Maximum
  • Set Point Adjustment
  • External Knobs
  • Compliance Standard
  • CE Marked
  • Enclosure Rating
  • NEMA 2 (IP51)
  • Switch Type
  • SPDT Relay Switches (2 Adjustable Set Points)
  • Contact Type
  • Gold-plated Contacts
  • Ambient Temperature Range
  • 20 to 120F (-6.7 to 48.9C)
  • Weight
  • 1.6 lbs (0.73 kg)
  • Repeatability
  • 1% of Full Scale
  • Power Supply
  • 120VAC, 240VAC or 24VDC Models Available
  • Electrical Rating
  • 5A @ 120/240 VAC
 

Dwyer 3050MRS Photohelic Switch/Gauge 0 to 50 inch Trade Information

  • Payment Terms
  • Cash in Advance (CID), Cash on Delivery (COD), Cash Against Delivery (CAD), Cash Advance (CA)
  • Main Export Market(s)
  • Asia
  • Main Domestic Market
  • All India
 

About Dwyer 3050MRS Photohelic Switch/Gauge 0 to 50 inch

Dwyer 3050MRS Photohelic Switch/Gauge 0 to 50 inch

 

Series 3000MR/3000MRS Photohelic® Switch/Gage

Combines Differential Pressure Gage with Low/High Set-Points,Compact Size

 

 ModelDescription 
 3050MRS-50 inchPressure Switch/Gage,Range 0-50 inch, 1.0 minor divisions.
 

 

Includes

  • mounting ring, snap ring
  • 18" cable assembly
  • (2) 3/16" tubing to 1/8" NPT adapters
  • (2) 1/8" NPT pipe plugs
  • (4) 6-32 x 1-1/4" RH machine screws (panel mounting)
  • (3) 6-32 x 5/16" RH machine screws (surface mounting)

he Series 3000MR Photohelic® Switch/Gage combine the functions of a precise, highly repeatable differential pressure switch with a large easy-to-read analog pressure gage employing the durable, time-proven Magnehelic® gage design. Switch setting is easy to adjust with large external knobs on the gage face. Gage reading is unaffected by switch operation - will indicate accurately even if power is interrupted. Solid state design now results in greatly reduced size and weight. Units can be flush mounted in 4-13/16" hole or surface mounted with hardware supplied. 3000MR models employ versatile electromechanical relays with gold over silver contacts - ideal for dry circuits.

Gage accuracy is ±2% of full scale and switch repeatability is ±1%. Switch deadband is one pointer width - less than 1% of full scale. Compatible with air and other non-combustible, non-corrosive gases, they can be used in systems with pressures to 25 psig.

Applications

  • Fan Control
  • Damper Control
  • Environmental Pollution Control

Approvals

  • CE Approval
  • GOST-R Certificate

Specification

Service Air and non-combustible, compatible gases 
Accuracy ±2% of FS at 70°F 
Pressure Limits -20" Hg to 25 psig 
Temperature Limits 20 to 120°F 
Process Connections 1/8 female NPT (duplicated side and back) 
Size 4" dial face, 5" O.D. x 3-1/8" 
 Weight1.8 lb 
 Switch Specifications 
 Switch TypeEach setpoint has 1 Form C relay (SPDT) 
 Relay Contacts(resistive load) 1 Form C rated 1.0A @ 30 VDC, 0.3A @ 110 VDC or 0.5A @ 125 VAC. Gold over clad silver - suitable for dry circuits 
 Electrical Connections18" cable assembly with 8 conductors 
 Power Requirements24 VDC, regulated ±10% 
 Mounting OrientationDiaphragm in vertical position 
Set Point Adjustment Adjustable knobs on face 
 Agency ApprovalsCE 


Versatile Pressure Monitoring and Control

The Dwyer 3050MRS Photohelic switch/gauge is designed to measure and control differential pressure in various applications, including steam, oil, and gas systems. Its dual SPDT relay switches enable automated control, while the analog display offers real-time monitoring. Ideal for industries needing precise pressure management, this solution integrates quick setup with panel or surface mounting flexibility.


Durable Construction and Practical Features

Built from die-cast aluminum with a corrosion-resistant black finish, the 3050MRS promises long-lasting durability even in challenging industrial environments. Its easy-to-read 4-inch acrylic dial, silicone rubber seals, and gold-plated contacts ensure maximum reliability. External knobs streamline set point adjustments, and detailed installation documentation is included for seamless integration.

FAQ's of Dwyer 3050MRS Photohelic Switch/Gauge 0 to 50 inch:


Q: How do I adjust the set points on the Dwyer 3050MRS Photohelic Switch/Gauge?

A: You can adjust the set points using the external knobs located on the device's front panel. These allow you to independently set the two SPDT relay switches without needing to open the enclosure.

Q: What power supply options are available for this gauge?

A: The Dwyer 3050MRS Photohelic Switch/Gauge supports three power supply options: 120VAC, 240VAC, or 24VDC. Select the model that matches your facility's available power for proper operation.

Q: Where can I use the Dwyer 3050MRS in an industrial setting?

A: This Photohelic gauge is suitable for environments requiring differential pressure monitoring and control, such as steam systems, oil lines, and gas distribution networks. Its NEMA 2 (IP51) enclosure rating is ideal for indoor installations with minimal exposure to dust or dripping water.

Q: What is the process for installing the 3050MRS gauge?

A: Installation is straightforward: use the provided mounting hardware for either surface or panel mounting. Electrical connections are made via screw terminals, and pressure connections utilize 1/8" NPT female fittings. An installation manual is included for reference.

Q: What are the main benefits of using the Dwyer 3050MRS Photohelic Switch/Gauge?

A: This instrument combines accurate analog pressure measurement with switch-based control, enabling precise automation and process protection. The external set point adjustment and gold-plated contacts enhance reliability and user convenience.

Q: How accurate and repeatable are the readings?

A: The 3050MRS provides accuracy within 2% of the full scale and repeatability of 1%, allowing you to trust your measurements and maintain consistent process control.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series 3000MR/3000MRS | Photohelic Switch Category

Dwyer 3030MRS Photohelic Switch/Gauge 0 to 30 inch

Dwyer 3030MRS Photohelic Switch/Gauge 0 to 30 inch

Mount Type : Other, Flush, Surface or Panel Mountable

Material : Other, Diecast aluminum case, acrylic cover

Seal Material : BunaN

Outer Size : 126 mm (5 in) dia. case

Scale Range : 0 to 30 inches of water column (in. w.c.)

Thread : 1/8 NPT Female

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 60 Pa

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 60 Pa

Mount Type : Other, Surface or flush mounting

Material : Other, Diecast aluminum housing

Seal Material : Neoprene

Outer Size : 4 (101.6 mm) diameter

Scale Range : 0 to 60 Pa

Thread : 1/8 NPT Female

Dwyer 3001MR Photohelic Differential Pressure Switch/Gauge Range: 0-1

Dwyer 3001MR Photohelic Differential Pressure Switch/Gauge Range: 0-1"w.c.

Mount Type : Other, Panel Mount

Material : Other, Die Cast Aluminum Case, Polycarbonate Lens

Seal Material : BunaN

Outer Size : 4 Inch (101.6 mm) Diameter

Scale Range : 01 w.c. (Inches of Water Column)

Thread : 1/8 NPT Female

Dwyer 3002MRS Photohelic, Switch/Gauge 0 to 2 in W.C

Dwyer 3002MRS Photohelic, Switch/Gauge 0 to 2 in W.C

Mount Type : Other, Flush or Surface

Material : Other, Diecast Aluminum Case

Seal Material : Silicone or BunaN

Outer Size : Approximately 4 OD (inches)

Scale Range : 0 to 2 in W.C

Thread : 1/8 NPT Female