Back to top
Dwyer 3000MRS Photohelic Switch/Gauge 0 to 10 MM
Dwyer 3000MRS Photohelic Switch/Gauge 0 to 10 MM

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 10 MM

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 10 MM Specification

  • Display
  • Analog
  • Thread
  • 1/8 NPT Female High and Low Pressure Connections
  • Grade
  • Industrial
  • Sensor Type
  • Photohelic Switch/Gauge
  • Seal Material
  • Silicone Rubber
  • Outer Size
  • 144 mm x 144 mm (Approx.)
  • Material
  • Die Cast Aluminum Housing
  • Dial Material
  • White Backlighted Plastic
  • Pointer Material
  • Aluminum
  • Processing Type
  • Factory Assembled
  • Diameter
  • Approx. 100 mm (Dial Face)
  • Glass Size
  • 100 mm
  • Mount Type
  • Panel Mount
  • Scale Range
  • 0 to 10 mm
  • Accuracy
  • 2% of Full Scale
  • Accessories
  • Standard Mounting Hardware, Instruction Manual
  • Electrical Connections
  • Screw Terminals
  • Switch Type
  • SPDT Snap Switch
  • Enclosure Rating
  • IP54
  • Contact Rating
  • 10A @ 120/240 VAC
  • Weight
  • Approx. 1.2 kg
  • Power Supply
  • 120/240 VAC, 50/60 Hz
  • Number of Switches
  • 2
  • Compliances
  • CE Marked
  • Operating Temperature Range
  • -20C to +60C
 

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 10 MM Trade Information

  • Payment Terms
  • Cash Advance (CA), Cash in Advance (CID), Cash on Delivery (COD), Cash Against Delivery (CAD)
  • Main Export Market(s)
  • Asia
  • Main Domestic Market
  • All India
 

About Dwyer 3000MRS Photohelic Switch/Gauge 0 to 10 MM

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 10 MM

Series 3000MR/3000MRS Photohelic® Switch/Gage

Combines Differential Pressure Gage with Low/High Set-Points,Compact Size

 

 ModelDescription 
 3000MRS-10 MMPressure Switch/Gage,Range 0 - 10 MM, .50 minor divisions.
 

 

Includes

  • mounting ring, snap ring
  • 18" cable assembly
  • (2) 3/16" tubing to 1/8" NPT adapters
  • (2) 1/8" NPT pipe plugs
  • (4) 6-32 x 1-1/4" RH machine screws (panel mounting)
  • (3) 6-32 x 5/16" RH machine screws (surface mounting)

he Series 3000MR Photohelic® Switch/Gage combine the functions of a precise, highly repeatable differential pressure switch with a large easy-to-read analog pressure gage employing the durable, time-proven Magnehelic® gage design. Switch setting is easy to adjust with large external knobs on the gage face. Gage reading is unaffected by switch operation - will indicate accurately even if power is interrupted. Solid state design now results in greatly reduced size and weight. Units can be flush mounted in 4-13/16" hole or surface mounted with hardware supplied. 3000MR models employ versatile electromechanical relays with gold over silver contacts - ideal for dry circuits.

Gage accuracy is ±2% of full scale and switch repeatability is ±1%. Switch deadband is one pointer width - less than 1% of full scale. Compatible with air and other non-combustible, non-corrosive gases, they can be used in systems with pressures to 25 psig.

Applications

  • Fan Control
  • Damper Control
  • Environmental Pollution Control

Approvals

  • CE Approval
  • GOST-R Certificate

Specification

Service Air and non-combustible, compatible gases 
Accuracy ±2% of FS at 70°F 
Pressure Limits -20" Hg to 25 psig 
Temperature Limits 20 to 120°F 
Process Connections 1/8 female NPT (duplicated side and back) 
Size 4" dial face, 5" O.D. x 3-1/8" 
 Weight1.8 lb 
 Switch Specifications 
 Switch TypeEach setpoint has 1 Form C relay (SPDT) 
 Relay Contacts(resistive load) 1 Form C rated 1.0A @ 30 VDC, 0.3A @ 110 VDC or 0.5A @ 125 VAC. Gold over clad silver - suitable for dry circuits 
 Electrical Connections18" cable assembly with 8 conductors 
 Power Requirements24 VDC, regulated ±10% 
 Mounting OrientationDiaphragm in vertical position 
Set Point Adjustment Adjustable knobs on face 
 Agency ApprovalsCE 


Robust Pressure Sensing for Demanding Environments

Engineered for industrial use, the Dwyer 3000MRS Photohelic Switch/Gauge ensures dependable pressure monitoring and switching. Its factory-assembled construction, silicone rubber seals, and die-cast aluminum housing provide excellent durability, while the IP54 enclosure guards against dust and splashing water-making it ideal for a range of process industries dealing with steam, oil, or gas.


Precision Control with Dual Switch Functionality

This device incorporates two SPDT snap switches, supporting advanced process control by providing both visual pressure readings and electrical switching. Designed for systems needing reliable status feedback, the 3000MRS supports efficient process automation while simplifying the integration into existing setups via screw terminals and standard 1/8 NPT female connections.

FAQ's of Dwyer 3000MRS Photohelic Switch/Gauge 0 to 10 MM:


Q: How do I install the Dwyer 3000MRS Photohelic Switch/Gauge?

A: Installation is straightforward using the provided standard mounting hardware. The device is designed for panel mounting, and electrical connections should be made using the screw terminals. Pressure inputs are connected via 1/8 NPT female threads for both high and low pressure.

Q: What is the primary benefit of the Photohelic switch/gauge design?

A: The Photohelic switch/gauge combines precise analog pressure measurement with electronic switching functions, enabling real-time monitoring and automatic control in a compact, integrated unit. This enhances system safety and optimizes process efficiency.

Q: When should I use this gauge in my process system?

A: The 3000MRS is ideal in any application where both pressure monitoring and automatic control are required, such as in steam, oil, or gas systems. Its accuracy and dual-switching capability make it suitable for controlling processes, detecting system deviations, or providing safety interlocks.

Q: Where can the Dwyer 3000MRS be deployed?

A: This switch/gauge is suitable for industrial environments, including refineries, chemical plants, and processing facilities. The IP54 enclosure rating means it can withstand dusty or mildly wet conditions but should not be submerged.

Q: What is the operational process for using the switches?

A: The dual SPDT snap switches activate when set pressure thresholds are reached. You can wire these switches into your process control system, allowing for automatic alerts, system shutdowns, or valve actuation based on real-time pressure readings.

Q: Is the gauge compliant with international standards?

A: Yes, the Dwyer 3000MRS is CE marked, ensuring it meets relevant European safety, health, and environmental requirements, making it suitable for use in regulated markets.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series 3000MR/3000MRS | Photohelic Switch Category

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 4 kPa

Dwyer 3000MRS Photohelic Switch/Gauge 0 to 4 kPa

Seal Material : Silicone rubber gasket

Scale Range : 0 to 4 kPa

Diameter : 4 inches (101.6 mm)

Outer Size : Standard 4 (101.6 mm) case

Sensor Type : Photohelic (Electromechanical Switch/Gauge)

Mount Type : Other, Flush mount or surface mount with accessory

Dwyer 3100MRS Photohelic Switch/Gauge 0 to 100 inch

Dwyer 3100MRS Photohelic Switch/Gauge 0 to 100 inch

Seal Material : BunaN

Scale Range : 0 to 100 inch w.c.

Diameter : 4 inch (101.6 mm)

Outer Size : Standard 4 (101.6 mm) Dial

Sensor Type : Differential Pressure Sensor

Mount Type : Other, Flush or Surface

Dwyer 3020MRS Photohelic Switch/Gauge 0 to 20 inch

Dwyer 3020MRS Photohelic Switch/Gauge 0 to 20 inch

Seal Material : Silicone Rubber

Scale Range : 0 to 20 inches of Water Column (in. w.c.)

Diameter : 4 inch (101.6 mm) dial

Outer Size : Standard 4 (101.6 mm) Case

Sensor Type : Photohelic Differential Pressure Sensor

Mount Type : Other, Flush Panel or Surface Mount

Dwyer 3030MRS Photohelic Switch/Gauge 0 to 30 inch

Dwyer 3030MRS Photohelic Switch/Gauge 0 to 30 inch

Seal Material : BunaN

Scale Range : 0 to 30 inches of water column (in. w.c.)

Diameter : 5 inches (126 mm)

Outer Size : 126 mm (5 in) dia. case

Sensor Type : Photohelic Differential Pressure Sensor

Mount Type : Other, Flush, Surface or Panel Mountable