Back to top
Dust Free Unit
Dust Free Unit

Dust Free Unit

Dust Free Unit Specification

  • Noise Level
  • Medium db
  • Material
  • Mild Steel
  • Features
  • Durable
  • Installation Type
  • Portable
  • Application
  • Industrial
  • Efficiency (%)
  • 99.5
  • Automatic Grade
  • Automatic
 
 

About Dust Free Unit

Dust Free Unit

We have gathered a huge customer base in this domain by manufacturing, exporting and supplying a wide range of Dust Free Unit. This unit is manufactured by our professionals by utilizing progressive machines and quality approved raw materials. The offered unit is applauded among the clients due to their optimum performance and corrosion resistant body. Furthermore, clients can avail this Dust Free Unit at viable prices from us.

Features:

  • Low noise generation
  • Rugged design
  • High performance
  • Easy installation
  • Ductable
  • Compact Size
  • Easy Maintenance
  • Energy Efficient
  • Access Door
  • Economical Operation
  • Low Noise
  • Easy Installation
  • Gasket Sealed Panel
  • Fresh Air Unit / Dust Free Unit
Unit Capacity:
  • From 2000 CFM to 50000 CFM or above

Casing: 
  • In double skin construction the structure is made of hollow aluminum profile with nylon corners and panels are made of 0. 6 mm thickness pre - coated outer sheet and gi inner sheet

  • The panels are insulated with injected puf (38kg / cubic m. ) / EPS slabs / kini foam

  • In single skin construction the structure is modular type, made of gi hollow profile and is mechanically bolted with top and bottom tray

  • Panels are made of 18g. Or 16g. (thickness varies according to the size of unit).

Blower:

  • The blowers used in unit are imported or indigenous and is centrifugal type forward curved for normal static pressure, mounted on rubber isolators for smooth and quite operation

  • Sant make blowers are dynamically and statically balanced on fie make computerized balancing machine.

Motor:

  • The motor used is drip proof mounted on specially designed adjustable motor base. Electrical supply normally is 3 ph / + / -415 volts.

Flat Filter Section:
  • Filter section channels are designed for 50 mm thick expanded aluminum mesh washable pre filters with easily removable facility.
Applications:
  • Malls
  • Offices
  • Hotels
  • Auditoriums
  • Restaurants
  • Hospitals
  • Shops
  • Clubs
  • Banks
  • Banquet Halls
  • Shopping Plazas

Other Information

  • Pay Mode Terms: T/T (Bank Transfer)



Exceptional Efficiency for Industrial Use

The Dust Free Unit consistently delivers a high performance with a filtration efficiency of 99.5%. Specifically designed for industrial applications, this system effectively captures and removes dust particles from the environment, safeguarding both equipment and personnel. Its advanced technology and automatic operation make it a reliable choice for maintaining clean air standards in facilities of varying scales.


Sturdy and Flexible Design

Constructed from mild steel, the Dust Free Unit ensures longevity and resilience, even in demanding industrial conditions. The portable installation type allows users to relocate and reconfigure the unit based on changing operational needs without hassle. Its moderate noise output maintains a comfortable working environment, while the unit's automatic functionality improves operational ease and reduces manual intervention.

FAQ's of Dust Free Unit:


Q: How does the Dust Free Unit operate to maintain air purity in industrial settings?

A: The unit incorporates an advanced filtration system that autonomously draws in contaminated air, removes dust particles using its high-efficiency mechanisms, and releases clean air back into the environment. This process helps sustain optimal air quality in industrial settings with minimal manual oversight.

Q: What materials is the Dust Free Unit made from and why is this important?

A: The Dust Free Unit is constructed from durable mild steel, which ensures robust performance, resistance to wear, and a longer operational lifespan even under harsh industrial conditions.

Q: When is the ideal time to use the Dust Free Unit during industrial operations?

A: It is best used during any process that generates airborne dust or particles, such as manufacturing, processing, or packaging, to maintain a cleaner and safer working environment throughout operational hours.

Q: Where can the Dust Free Unit be installed within a facility?

A: Thanks to its portable installation type, the unit can be set up in various locations across the facility, particularly near dust-generating machinery or processes. It allows for flexible placement and easy relocation as operational needs evolve.

Q: What is the process for installing and commissioning the Dust Free Unit?

A: Installation is straightforward due to its portable design. Typically, it involves positioning the unit near an area with significant dust generation, connecting it to a power source, and activating its automatic settings for immediate operation.

Q: How should the Dust Free Unit be used for optimal results?

A: For best performance, the unit should operate continuously during dusty processes. Routine checks and maintenance, as outlined in the user manual, will help sustain its 99.5% efficiency rate.

Q: What are the primary benefits of using the Dust Free Unit in an industrial application?

A: The main advantages include improved air quality, protection of staff and sensitive equipment, adaptable placement, durable construction, and reliable, automatic, high-efficiency operation with manageable noise levels.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Air Handling Units Category

Inline Fan Belt Drive

Inline Fan Belt Drive

Material : Galvanized Steel

Application : Ventilation, Exhaust, Air Handling

Automatic Grade : SemiAutomatic

Installation Type : Other, Horizontal/Vertical

Features : Robust Belt Drive, Low Vibration, Easy Service

Efficiency (%) : Up to 72%

Floor Mounted Air Handling Unit

Floor Mounted Air Handling Unit

Material : Metal with Coating

Application : Air Handling

Automatic Grade : Automatic

Installation Type : Other, Floor Mounted

Features : Floor Mounted Design Durable Build Easy Maintenance

Efficiency (%) : High

Double Skin Horizontal Floor Mounted

Double Skin Horizontal Floor Mounted

Material : Metal Exterior with Insulated Panels

Application : Air Filtration

Automatic Grade : SemiAutomatic

Installation Type : Floor Mounted, Other

Features : Durable Construction Easy Maintenance

Efficiency (%) : High Efficiency

Pressure Smoke Protection Fan

Pressure Smoke Protection Fan

Material : Metal

Application : Pressure Smoke Protection

Automatic Grade : Other, Manual

Installation Type : WallMounted

Features : Durable and reliable for smoke pressure protection

Efficiency (%) : High