Back to top
Axial Seal HVAC Filters
Axial Seal HVAC Filters

Axial Seal HVAC Filters

Axial Seal HVAC Filters Specification

  • Filter Type
  • Panel Filter, Axial Seal
  • Flow Rate
  • 800 - 2400 m/h
  • Media Type
  • Synthetic Fiber
  • Efficiency (%)
  • Up to 95% (for particles >1 micron)
  • Connecting Type
  • Axial Seal, Slip-on Type
  • Filtration Grade
  • Medium
  • Temperature Range
  • Up to 80C
  • Pressure
  • Initial Resistance 120 Pa
  • Cleaning Method
  • Non-washable, Disposable
  • Capacity
  • High Dust Loading
  • Condition
  • New
  • Material
  • Synthetic Fiber Media, Galvanized Iron Frame
  • Mesh
  • Multi-Layer Synthetic Mesh
  • Diameter
  • Standard: 610mm, Custom sizes available
  • Construction
  • Rigid Panel with Axial Rubber Seal
  • Medium Filter
  • Yes
  • Weight
  • Approx. 4.5 kg
  • Shape
  • Rectangular
  • Feature
  • High dust holding capacity, axial seal design for leak-proof operation
 

Axial Seal HVAC Filters Trade Information

  • Main Export Market(s)
  • Asia
  • Main Domestic Market
  • All India
 

About Axial Seal HVAC Filters

Axial Seal HVAC Filters

Specifications:

  • Material Used: Aluminium anodized
  • Flow: Standard Flow

Applications:

  • Coolant,

  • Cutting,

  • Oil and Lubricant

Features:

  •  High Dwell Time
  •  Low Pressure Drop
  •  Long Life
  •  High Dust Holding Capacity





Optimal Filtration Performance

Utilizing high-quality synthetic fiber media and a multi-layer mesh design, these filters deliver up to 95% efficiency for particles larger than 1 micron. Their axial seal ensures minimal leakage, making them ideal for environments where air cleanliness is crucial, such as clean rooms and industrial facilities.


Flexible Options for Diverse Applications

Available in various frame thicknesses and customizable sizes, Axial Seal HVAC Filters are suitable for a wide range of HVAC configurations. Whether used as pre-filters or fine filters, their robust construction supports high dust loading, making them highly adaptable for demanding conditions.


Reliable and Simple Installation

With panel filter design and slip-on axial sealing, installation into air handling units or return air grilles is straightforward. Each filter is packed individually to maintain cleanliness during transport and storage.

FAQs of Axial Seal HVAC Filters:


Q: How do Axial Seal HVAC Filters ensure leak-proof operation in air handling units?

A: These filters incorporate a robust rubber gasket axial seal along the frame, which creates an airtight connection when installed. This design prevents any bypass of unfiltered air, ensuring all air passes through the filter media for optimal purification.

Q: What are the recommended applications for these panel filters?

A: Axial Seal HVAC Filters are especially suited for HVAC systems, clean rooms, and industrial ventilation. They can be used as pre-filters or fine filters in air handling units and are also appropriate for panel or return air grille installations.

Q: When should these filters be replaced for best performance?

A: It is advisable to replace the filters every 6 to 12 months, depending on environmental dust load, humidity, and operational hours. Regular replacement ensures consistent efficiency and prolongs the service life of air handling systems.

Q: Where are these filters most commonly installed?

A: They are typically fitted in panel positions or return air grilles within HVAC units to act as the first or secondary filtration stage. Their customizable dimensions also make them the right choice for specialized installations, such as in clean rooms and industrial applications.

Q: What makes the synthetic fiber media advantageous for filtration?

A: Synthetic fiber provides high dust holding capacity and excellent efficiency for particles larger than 1 micron, all while withstanding high humidity levels (up to 95% RH) and temperatures up to 80C. This leads to consistent performance throughout the filters lifespan.

Q: How do users benefit from the high dust loading capacity of these filters?

A: The enhanced dust loading capability reduces the need for frequent replacements, minimizing operational interruptions and maintenance efforts while maintaining indoor air quality effectively.

Q: Are these filters reusable or should they be disposed of after use?

A: Axial Seal HVAC Filters are designed for single-use, non-washable operation. After reaching their capacity or lifespan, they should be properly disposed of and replaced with new filters to ensure ongoing air quality and system protection.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gas Turbine Air Intake Filters Category

Cylindrical HEPA Filter

Cylindrical HEPA Filter

Shape : Cylindrical

Feature : High efficiency particulate air filtration

Medium Filter : Other, HEPA filter media

Construction : Other, Cylindrical pleated construction

Connecting Type : Other, End cap flange

Condition : New

Industrial Gas Filter

Industrial Gas Filter

Shape : Cylindrical

Feature : High dirt holding capacity, Robust construction, Easy installation

Medium Filter : Other, Natural Gas, Biogas, Air

Construction : Other, Seamless welded body

Connecting Type : Flanged

Condition : New

Filter Baskets

Filter Baskets

Shape : Cylindrical, basketshaped

Feature : Corrosion resistance, easy installation, reusable, high dirt holding capacity

Medium Filter : Other, Liquid, gas, air

Construction : Other, Welded, seamless body

Connecting Type : Other, Flanged, threaded ends

Condition : New

Hydraulic Filter for 1800 Concrete Pump

Hydraulic Filter for 1800 Concrete Pump

Shape : Cylinder

Feature : High filtration efficiency for hydraulic systems, suitable for heavyduty concrete pumps

Medium Filter : Other, Hydraulic oil

Construction : Other, Robust cylindrical cartridge design

Connecting Type : Other, Threaded or flanged end connection

Condition : New