About Analog India NO 1 GEMTECH Differential Pressure Gauge

Analog India NO 1 GEMTECH Differential Pressure Gauge
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION
- Ambient Temperature - -21 ~140 -6 ~60
- Rated Pressure -20 inHg~30 inHg (-68~103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel,with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - A2% of full span at 70(21(A3% on -0, and A4% on -00)
- Range -20 inHg~38 inHg (-68KPa~130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERINGGEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model |
Description |
| G2000-100MM |
DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
DPG,Range 0-150 MM W.C. |
| G2000-15MM |
DPG,Range 0-15 MM W.C. |
| G2000-200MM |
DPG,Range 0-200 MM W.C. |
| G2000-250MM |
DPG,Range 0-250 MM W.C. |
| G2000-25MM |
DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
DPG,Range 0-300 MM W.C. |
| G2000-50MM |
DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
WhatsAppNo.9871014210,
WhatsAppNo.9811065204,
WhatsApp No.8376899729,
WhatsApp No.8368888047,
WhatsApp No.9268631221,

Engineered for Operational ExcellenceGEMTECH's Differential Pressure Gauge is designed to meet the dynamic requirements of multiple industries, ensuring accurate measurements and reliable operation in demanding contexts. Its stainless steel construction and varied finishes cater to both durability and visual integration with professional settings.
Wide Application SpectrumFrom hospitals and pharmaceutical manufacturing to large-scale power and steel plants, this gauge excels in diverse usage environments. Whether monitoring system pressure in malls or ensuring compliance in food processing, it supports essential safety and efficiency standards.
FAQ's of Analog India NO 1 GEMTECH Differential Pressure Gauge:
Q: How do I install the GEMTECH Differential Pressure Gauge for optimal accuracy?
A: Mount the gauge using its back mounting design and 1/8 inch thread connection. Ensure that the installation site is free from vibration and temperature extremes. Proper alignment and stiff connections enhance the 2% accuracy for pressure readings.
Q: What types of pressure can this gauge measure?
A: This gauge measures differential pressure in steam and gas systems. Its scalable outputs are expressed in MM WC, CM, Pa, KPA, and inches, allowing for flexible monitoring depending on your system requirements.
Q: When should I use this gauge in an industrial setup?
A: Use the GEMTECH Differential Pressure Gauge whenever you need reliable, real-time monitoring of pressure differences-especially in critical systems within hotels, hospitals, power plants, fertilizer units, and more. It's particularly effective where pressure control is linked to safety and process efficiency.
Q: Where can this gauge be applied within various industries?
A: The gauge is suitable for a wide range of applications, including pharmaceutical manufacturing, hotels, malls, hospitals, OT rooms, power plants, cement, steel, fertilizer, textile, food and beverages, and pulp and paper industries. Its versatility makes it adaptable across diverse operational environments.
Q: What is the process for scaling or recalibrating the gauge?
A: Recalibration should be performed by qualified technicians. The process involves comparing the gauge readings with a certified standard and adjusting the pointer or mechanism as necessary. Regular recalibration ensures sustained accuracy in industrial applications.
Q: What are the key benefits of using this differential pressure gauge?
A: Key benefits include precision measurement with 2% accuracy, robust stainless steel construction for longevity, versatile scale ranges for varied industry needs, and multiple finishing options for compatibility with equipment aesthetics and hygiene requirements.