Back to top
Nicotra Backward Curved Centrifugal Fan RDH 180 R
Nicotra Backward Curved Centrifugal Fan RDH 180 R
Nicotra Backward Curved Centrifugal Fan RDH 180 R
Nicotra Backward Curved Centrifugal Fan RDH 180 R
Nicotra Backward Curved Centrifugal Fan RDH 180 R
Nicotra Backward Curved Centrifugal Fan RDH 180 R
Nicotra Backward Curved Centrifugal Fan RDH 180 R
Nicotra Backward Curved Centrifugal Fan RDH 180 R
Nicotra Backward Curved Centrifugal Fan RDH 180 R
Nicotra Backward Curved Centrifugal Fan RDH 180 R
Nicotra Backward Curved Centrifugal Fan RDH 180 R
Nicotra Backward Curved Centrifugal Fan RDH 180 R

Nicotra Backward Curved Centrifugal Fan RDH 180 R

MOQ : 1 Piece

Nicotra Backward Curved Centrifugal Fan RDH 180 R Specification

  • Motor Power
  • 0.20 kW
  • Flow Rate
  • Up to 900 m/h
  • Pressure Range
  • 0 475 Pa
  • Max Pressure
  • 475 Pa
  • Power
  • 0.20 kW
  • Output Power
  • 0.20 kW
  • Life Span
  • 40,000 hours
  • Product Type
  • Backward Curved Centrifugal Fan
  • Material
  • Galvanized Steel
  • Capacity
  • Up to 900 m/h
  • Pressure
  • Approx. 475 Pa
  • Frequency (MHz)
  • 50 Hz
  • Motor Speed
  • 2800 RPM
  • Noise Level
  • Below 68 dB(A) at 1 meter
  • Power Source
  • Electric
  • Voltage
  • 230 V AC
  • Weight
  • 7.2 kg
  • Dimension (L*W*H)
  • 325 x 280 x 300 mm
  • Color
  • Silver Grey
  • Operating Temperature Range
  • -20C to +60C
  • Drive Type
  • Direct Drive
  • Impeller Type
  • Backward Curved
  • Bearing Type
  • Double Sealed Ball Bearings
  • Airflow Direction
  • Centrifugal
  • Fan Housing Material
  • Galvanized Steel
  • Model
  • RDH 180 R
  • Mounting Type
  • Flange mounted
  • Blade Material
  • Aluminium
  • Protection Rating
  • IP54
  • Motor Type
  • Single Phase/Three Phase Asynchronous Motor
  • Insulation Class
  • Class F
  • Compliance
  • CE Certified
  • Installation Position
  • Horizontal or Vertical
 

Nicotra Backward Curved Centrifugal Fan RDH 180 R Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Advance (CA), Cash Against Delivery (CAD), Cash on Delivery (COD), Cash in Advance (CID)
  • Main Export Market(s)
  • Western Europe, Asia, Africa, Eastern Europe, Middle East, Central America, North America, Australia, South America
  • Main Domestic Market
  • All India
 

About Nicotra Backward Curved Centrifugal Fan RDH 180 R

Nicotra Backward Curved Centrifugal Fan RDH 180 R

 

 Product RDH 180 R 
Brand  Nicotra 
Description  Extractor Fan 
 Condition New  

  

Find Cheap Spare Parts For Machines Using The Products of Nicotra.Our Team of experts will find the best sales prices for products of Nicotra - RDH 180 R Extractor Fan in USA.Using the products of Nicotra will minimize your costs on spare parts.Our job is to save you time and minimize your expenses on spare parts and industrial components.Our company is not an official distributor of Nicotra, but we are selling their products at competitive prices.Purchase high quality spare parts of Nicotra - RDH 180 R Extractor fan in INDIA on cheap prices.With each day we gain more and more experience and that's why we are able to satisfy your needs for spare parts.




Sturdy Construction & Durable Performance

The RDH 180 R centrifugal fan is built with a galvanized steel housing and an aluminium backward curved impeller, ensuring excellent resistance to corrosion and mechanical wear. Its double sealed ball bearings and robust class F insulated motor deliver an operational lifespan of up to 40,000 hours, making it a reliable solution for industrial and commercial ventilation.


Flexible Installation & Optimal Airflow

Designed to meet diverse application needs, this fan offers flange mounting and can be positioned horizontally or vertically. It operates at 2800 RPM, providing efficient air delivery up to 900 m/h for a variety of HVAC tasks. The direct drive design means simplified maintenance and consistent performance over time.


Silent, Safe, and Certified Operation

Operating at a noise level below 68 dB(A) at one meter, the RDH 180 R is suited for environments where low sound emissions are important. It is CE certified and equipped with IP54 protection, safeguarding the components from dust and splash water. This combination ensures safe, whisper-quiet performance in demanding scenarios.

FAQs of Nicotra Backward Curved Centrifugal Fan RDH 180 R:


Q: How should the RDH 180 R centrifugal fan be installed for optimal performance?

A: The fan can be mounted either horizontally or vertically using its flange-mounted design, offering flexibility in placement. It is essential to ensure adequate clearance for airflow and routine maintenance, and installation should follow the manufacturers guidelines for wiring and mounting to optimize performance and lifespan.

Q: What are the main benefits of using a backward curved centrifugal fan like the RDH 180 R?

A: Backward curved centrifugal fans provide higher efficiency, lower noise levels, and greater resistance to dust accumulation compared to other impeller designs. The RDH 180 R features an aluminium impeller and direct drive, maximizing durability and reducing maintenance needs.

Q: When is the RDH 180 R fan best suited for use?

A: This fan is ideal for continuous operation in HVAC systems, industrial ventilation, and building exhaust scenarios, especially where reliable airflow and moderate pressure are required. It functions smoothly within a temperature range of -20C to +60C, making it suitable for diverse environments.

Q: Where can the RDH 180 R be installed?

A: This fan can be installed in commercial buildings, factories, or any space requiring effective air movement and extraction. Thanks to its compact design and moderate weight (7.2 kg), it can be fitted into confined spaces or mounted on walls and ceilings where ventilation is needed.

Q: What is the process for maintaining the RDH 180 R centrifugal fan?

A: Regular inspection of the impeller and motor for debris, checking that bearings are functioning smoothly, and verifying electrical connections are recommended. Its double sealed ball bearings and direct drive minimize maintenance requirements, but periodic cleaning and routine checks will extend its operational life.

Q: What makes the RDH 180 R fan suitable for industrial and HVAC applications?

A: With a galvanized steel housing, IP54 protection, and a powerful, efficient motor, this fan can withstand demanding industrial conditions. Its CE certification and low noise levels further enhance its suitability for various HVAC and building applications, ensuring consistent air delivery with minimal disruption.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Series RDH Nicotra Backard Curved Centrifugal Fan- Category

Nicotra Backward Curved Centrifugal Fan RDH 500 R

Nicotra Backward Curved Centrifugal Fan RDH 500 R

Price 50000.00 INR

Minimum Order Quantity : 1 Piece

Weight : 55 kg

Frequency (MHz) : 50 Hz

Noise Level : 72 dB(A)

Dimension (L*W*H) : 730 x 730 x 470 mm

Nicotra Backward Curved Centrifugal Fan RDH 800 K

Nicotra Backward Curved Centrifugal Fan RDH 800 K

Price 140000.00 INR

Minimum Order Quantity : 1 Piece

Weight : 235 kg

Frequency (MHz) : 50 Hz

Noise Level : 80 dBA

Dimension (L*W*H) : 1050 mm x 1100 mm x 950 mm

Nicotra Backward Curved Centrifugal Fan RDH 400 R

Nicotra Backward Curved Centrifugal Fan RDH 400 R

Price 36000.00 INR

Minimum Order Quantity : 1 Piece

Weight : Approx. 28 kg

Frequency (MHz) : 50 Hz

Noise Level : <69 dB(A)

Dimension (L*W*H) : Approx. 480mm x 480mm x 440mm

Nicotra Backward Curved Centrifugal Fan RDH 900 K

Nicotra Backward Curved Centrifugal Fan RDH 900 K

Price 175000.00 INR

Minimum Order Quantity : 1 Piece

Weight : 310 kg

Frequency (MHz) : 50 Hz

Noise Level : Below 85 dB(A)

Dimension (L*W*H) : 1200 mm x 1150 mm x 910 mm (approx.)