Back to top
Dwyer 2000-OD Magnehelic Differential Pressure Gauge
Dwyer 2000-OD Magnehelic Differential Pressure Gauge

Dwyer 2000-OD Magnehelic Differential Pressure Gauge

MOQ : 10 Pieces

Dwyer 2000-OD Magnehelic Differential Pressure Gauge Specification

  • Seal Material
  • Silicone or Buna-N diaphragm (model dependent)
  • Outer Size
  • Standard, see dimensions
  • Grade
  • Industrial Grade
  • Display
  • Analog
  • Sensor Type
  • Diaphragm Actuated
  • Thread
  • 1/8 NPT
  • Material
  • Die-cast Aluminum Case
  • Dial Material
  • Plastic
  • Pointer Material
  • Plastic
  • Processing Type
  • Precision Mechanical
  • Diameter
  • 4 inch (101.6 mm)
  • Glass Size
  • 4 inch (nominal)
  • Mount Type
  • Surface or Flush Mount
  • Scale Range
  • 0-0.5 to 0-60 inch w.c.; kPa and mm ranges optional
  • Accuracy
  • 2% of full scale
  • Finishing
  • Matte, Polished
  • Measure Pressure Of
  • Air and Non-corrosive Gases
  • Accessories
  • Two 1/8 NPT plugs, two mounting screws, and panel mounting hardware
  • Application
  • Filter monitoring, fan control, clean room pressure, etc.
  • Pressure Connections
  • High and low pressure taps on side and back
  • Mounting Orientation
  • Vertical
  • Zero Adjustment
  • External Knob
  • Model Number
  • 2000-OD
  • Damping Feature
  • Standard for pointer stability
  • Enclosure Protection
  • IP50
  • Frequency Response
  • Not specified (designed for steady pressure)
  • Overpressure Limit
  • 15 PSI (1.03 bar)
  • Window Material
  • Shatter-resistant clear acrylic
  • Weight
  • Approximately 454 g (1 lb)
  • Operating Temperature
  • 20F to 140F (-6.67C to 60C)
 

Dwyer 2000-OD Magnehelic Differential Pressure Gauge Trade Information

  • Minimum Order Quantity
  • 10 Pieces
  • FOB Port
  • Delhi
  • Payment Terms
  • Cash on Delivery (COD), Cash Advance (CA), Cash Against Delivery (CAD), Cash in Advance (CID)
  • Main Export Market(s)
  • Middle East, Asia
  • Main Domestic Market
  • Dadra and Nagar Haveli, Chandigarh, Himachal Pradesh, Meghalaya, Andaman and Nicobar Islands, Pondicherry, Nagaland, Uttarakhand, Daman and Diu, South India, East India, Assam, Arunachal Pradesh, Bihar, Delhi, Gujarat, Goa, Jammu and Kashmir, Jharkhand, Maharashtra, Mizoram, Manipur, Punjab, Rajasthan, Sikkim, Tamil Nadu, Telangana, Tripura, West Bengal, Lakshadweep, Uttar Pradesh, Haryana, Madhya Pradesh, Karnataka, North India, Andhra Pradesh, Kerala, Central India, Odisha, West India, Chhattisgarh, All India
 

About Dwyer 2000-OD Magnehelic Differential Pressure Gauge

Dwyer 2000-OD Magnehelic Differential Pressure Gauge

Dwyer InstrumentsA 2000-OD

Differential Pressure Gage 0-.05 in H2O, 0-125 Pascals

Select the Magnehelic gage for high accuracy--guaranteed within 2% of full scale--and for the wide choice of 81 models available to suit your needs precisely. Using Dwyer's simple, frictionless Magnehelic gage movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It's inexpensive, too. The Magnehelic gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment.

Product Highlights

  • Bezel provides flange for flush mounting in panel.

  • Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.

  • Precision litho-printed scale is accurate and easy to read.

  • Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft.

  • Pointer stops of molded rubber prevent pointer over-travel without damage.

  • "Wishbone" assembly provides mounting for helix, helix bearings and pointer shaft.

  • Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid.

  • Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness.

  • Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale.

  • Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration.

  • Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.

  • Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test.

  • Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting.

Overpressure Protection

Blowout plug is comprised of a rubber plug on the rear which functions as a relief valve by unseating and venting the gage interior when over pressure reaches approximately 25 PSIg (1.7 bar). To provide a free path for pressure relief, there are four spacer pads which maintain 0.023" clearance when gage is surface mounted. Do not obstruct the gap created by these pads. The blowout plug is not used on models above 180" of water pressure, medium or high pressure models, or on gages which require an elastomer other than silicone for the diaphragm. The blowout plug should not be used as a system overpressure control. High supply pressures may still cause the gage to fail due to over pressurization, resulting in property damage or serious injury. Good engineering practices should be utilized to prevent your system from exceeding the ratings or any component.

O-ring seal for cover assures pressure integrity of case. Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.

  • RangeA 0-.05 in H2O

  • 0-125 Pa



Reliable Differential Pressure Monitoring

Engineered with industrial-grade components, the Dwyer 2000-OD Magnehelic Gauge ensures accurate monitoring of air and non-corrosive gases in demanding environments such as clean rooms and HVAC systems. Its rugged construction and mechanical precision provide dependable readings, even under continuous use.


Versatile Installation Options

This gauge supports both surface and flush mounting for flexible integration into various setups. Included accessories such as 1/8 NPT plugs, mounting screws, and panel hardware simplify the installation process for professional and industrial applications.


Easy Calibration and Maintenance

An external adjustment knob allows for straightforward zero calibration without disassembly. The shatter-resistant acrylic window and robust die-cast aluminum enclosure offer durability, while the matte or polished finish ensures a professional appearance in any industrial setting.

FAQ's of Dwyer 2000-OD Magnehelic Differential Pressure Gauge:


Q: How is the Dwyer 2000-OD Magnehelic Differential Pressure Gauge installed?

A: The gauge can be mounted vertically using either flush or surface mounting methods. All necessary mounting hardware, including two 1/8 NPT plugs and mounting screws, is supplied for quick installation onto panels or control surfaces.

Q: What types of media can the Dwyer 2000-OD measure?

A: This gauge is designed to measure the differential pressure of air and non-corrosive gases, making it suitable for a wide range of HVAC, clean room, and process applications.

Q: When should I use the external zero adjustment knob?

A: Use the external zero adjustment knob during initial installation or periodic maintenance to recalibrate the gauge, ensuring the pointer reads zero when there is no applied differential pressure.

Q: Where can the Dwyer 2000-OD be effectively applied?

A: It is widely used in filter monitoring, fan and blower control, duct static pressure monitoring, and maintaining clean room standards where accurate differential pressure readings are critical.

Q: What is the benefit of the damping feature in this gauge?

A: The built-in damping provides pointer stability, reducing fluctuations and making it easier to read steady pressure values, especially in applications that experience minor pulsations.

Q: How do I connect the pressure taps for this gauge?

A: High and low pressure taps are located on both the side and back of the gauge body, allowing flexible connection options for 1/8 NPT fittings.

Q: What protection does the enclosure offer and what is the overpressure limit?

A: The die-cast aluminum enclosure meets IP50 protection standards, safeguarding against dust ingress. The gauge can safely handle overpressures up to 15 PSI (1.03 bar) without damage.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sensocon - Dwyer S2000 Pressure Gauge Category

Dwyer USA Magnehelic Gauges 0 To 25 MM WC

Dwyer USA Magnehelic Gauges 0 To 25 MM WC

Price 6900 INR / Piece

Minimum Order Quantity : 10 Pieces

Thread : 1/8 NPT Female

Accessories : Mounting Screws, Two Static Pressure Tips, Rubber Tubing

Diameter : 115 mm

Pointer Material : Other, Red Indicator Needle

Dwyer 2010-AV Magnehelic Differential Pressure Gauge

Dwyer 2010-AV Magnehelic Differential Pressure Gauge

Price 9871014210 INR

Minimum Order Quantity : 10 Pieces

Thread : 1/8 NPT Female Ports

Accessories : Mounting bracket, screws, 2 plastic tubing, 2 static pressure tips, 3 rubber stoppers, 2 mounting screws, 1 instruction manual

Diameter : 117 mm (41/2 in.)

Pointer Material : Aluminum

Dwyer USA Model 2180 Magnehelic Gage Range 0-180 Inch WC

Dwyer USA Model 2180 Magnehelic Gage Range 0-180 Inch WC

Minimum Order Quantity : 10 Pieces

Thread : 1/8 NPT Female

Accessories : Mounting Bracket, Two 1/8 NPT Plugs, Instructions

Diameter : 5 inch

Pointer Material : Aluminum

Dwyer USA 2005 Magnehelic Gage Range 0-5.0 Inch WC

Dwyer USA 2005 Magnehelic Gage Range 0-5.0 Inch WC

Minimum Order Quantity : 10 Pieces

Thread : 1/8 NPT

Accessories : Mounting Hardware Included

Diameter : 4 Inches

Pointer Material : Aluminum