Dwyer USA Model 2180 Magnehelic Gage Range 0-180 Inch WC Specification

  • Sensor Type
  • Differential Pressure Sensor
  • Bourdon Tube
  • Not Applicable (Diaphragm Mechanism)
  • Outer Size
  • 5 inch Diameter
  • Seal Material
  • Silicone Rubber
  • Grade
  • Industrial Grade
  • Thread
  • 1/8 NPT Female
  • Display
  • Analog Dial
  • Material
  • Die-cast Aluminum Case, Acrylic Lens
  • Dial Material
  • Acrylic
  • Pointer Material
  • Aluminum
  • Processing Type
  • Molded Plastic Case, Precision Mechanism
  • Diameter
  • 5 inch
  • Glass Size
  • Fits 5 inch Dial
  • Mount Type
  • Surface or Panel Mount
  • Scale Range
  • 0-180 Inch WC (Water Column)
  • Accuracy
  • 2% of Full Scale
  • Finishing
  • Semi-Gloss Black Enamel Case Finish
  • Measure Pressure Of
  • Air and Non-Corrosive Gases
  • Accessories
  • Mounting Bracket, Two 1/8 NPT Plugs, Instructions
 

Dwyer USA Model 2180 Magnehelic Gage Range 0-180 Inch WC Trade Information

  • Minimum Order Quantity
  • 10 Pieces
  • Payment Terms
  • Cash on Delivery (COD), Cash Advance (CA), Cash Against Delivery (CAD), Cash in Advance (CID)
  • Main Export Market(s)
  • Asia, Middle East
  • Main Domestic Market
  • Dadra and Nagar Haveli, Himachal Pradesh, Andaman and Nicobar Islands, Uttarakhand, Daman and Diu, South India, East India, West India, Assam, Arunachal Pradesh, Bihar, Chandigarh, Delhi, Goa, Jammu and Kashmir, Jharkhand, Karnataka, Madhya Pradesh, Maharashtra, Mizoram, Meghalaya, Manipur, Pondicherry, Rajasthan, Sikkim, Tamil Nadu, Telangana, Tripura, West Bengal, Nagaland, Lakshadweep, Uttar Pradesh, Haryana, Gujarat, North India, Punjab, Andhra Pradesh, Kerala, Central India, Odisha, Chhattisgarh, All India
 

About Dwyer USA Model 2180 Magnehelic Gage Range 0-180 Inch WC

Dwyer USA Model 2180 Magnehelic Gage Range 0-180 Inch WC

Description

Dwyer 2180 Differential pressure gage, range 0-180" w.c. (inches of water), minor divisions 5.

Using Dwyers simple, frictionlessMagnehelic Gagemovement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. Its inexpensive, too.

The Magnehelic Gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment.

Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi.

Features

Bezel provides flange for flush mounting in panel.

Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale.

Precision litho-printed scale is accurate and easy to read.

Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft.

Pointer stops of molded rubber prevent pointer over-travel without damage.

"Wishbone" assembly provides mounting for helix, helix bearings and pointer shaft.

Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid.

Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness.

Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale.

Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.

Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration.

Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures.

Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test. Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting.

Blowout plug of silicone rubber protects against overpressure on 15 psig rated models. Opens at approximately 25 psig.

O-ring seal for cover assures pressure integrity of case.



Accurate Differential Pressure Monitoring

The Dwyer Model 2180 Magnehelic Gage delivers 2% full scale accuracy for critical monitoring of air and non-corrosive gases in various industrial environments. Its analog dial and clear acrylic cover ensure quick, unambiguous readings, while the diaphragm mechanism provides reliable and repeatable results in measuring system pressures and filter status.


Rugged Construction and Easy Maintenance

Constructed from die-cast aluminum with a molded plastic case and silicone rubber seals, the gage withstands harsh conditions and resists mechanical wear. The external adjustment screw simplifies zero calibration without disassembly, and the device is maintenance-friendly for users in high-demand operations.


Versatile Installation Options

With a 5-inch dial, the Model 2180 accommodates both surface and panel mounting, featuring side and back 1/8 NPT female thread connections. Its included accessories and straightforward instructions streamline the installation for varied industrial setups, supporting dependable usage in Indias dynamic market environments.

FAQs of Dwyer USA Model 2180 Magnehelic Gage Range 0-180 Inch WC:


Q: How do I properly install the Dwyer Model 2180 Magnehelic Gage?

A: The Model 2180 can be mounted vertically on a surface or panel using the included mounting bracket. Ensure that the 1/8 NPT female connections are securely fitted to the pressure source, following the provided instructions for leak-free installation.

Q: What is the main application of the Model 2180 Magnehelic Gage?

A: This gauge is specifically designed to monitor differential pressure in applications such as filter status, fan and blower pressures, duct pressures, and clean room pressurization, making it highly suitable for industrial environments.

Q: When should I use the external zero adjustment screw?

A: The external zero adjustment screw allows you to recalibrate the gauge to zero whenever ambient conditions or mounting orientation cause the needle to drift, ensuring measurement accuracy over time.

Q: Where are the connection ports located on the Model 2180?

A: Connection ports are located on both the side and back of the gauge. This dual configuration provides flexibility when integrating the gauge into various pressure monitoring systems.

Q: What are the benefits of using a diaphragm mechanism in this gauge?

A: The diaphragm mechanism in the Model 2180 delivers high precision and durability, ensuring consistent measurement performance without the need for a Bourdon tube, especially in environments where vibration may be present.

Q: How does the Model 2180 handle different environmental conditions?

A: Designed for industrial grade use, the case material and seals allow operation from -20C to +60C and up to 15 psig, making it suitable for rigorous and varying temperature and pressure conditions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sensocon - Dwyer S2000 Pressure Gauge Category

Dwyer 2000-500PA Magnehelic Differential Pressure Gauge

Dwyer 2000-500PA Magnehelic Differential Pressure Gauge

Price 5100 INR

Minimum Order Quantity : 10 Pieces

Finishing : Other, Powdercoated casing

Accuracy : 2% of full scale

Material : Other, Diecast aluminum case, polycarbonate lens

Measure Pressure Of : Other, Air and compatible gases

Dwyer USA Model 2010 Magnehelic Gage Range 0-10 Inch WC

Dwyer USA Model 2010 Magnehelic Gage Range 0-10 Inch WC

Minimum Order Quantity : 10 Pieces

Finishing : Other, Black DieCast Aluminum Case with Painted Finish

Accuracy : 2% of Full Scale

Material : Other, DieCast Aluminum Housing, Acrylic Lens

Measure Pressure Of : Other, Air and Compatible Gases

Dwyer 2300-60PA Differential Pressure Gage Range 30-0-30 Pa

Dwyer 2300-60PA Differential Pressure Gage Range 30-0-30 Pa

Price 3400 INR

Minimum Order Quantity : 5 Pieces

Finishing : Polished

Dwyer 2010D Magnehelic Differential Pressure Gauge

Dwyer 2010D Magnehelic Differential Pressure Gauge

Price 9871014210 INR

Minimum Order Quantity : 10 Pieces

Finishing : Matte, Polished, Galvanized