Back to top
Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar
Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar

MOQ : 5 Pieces

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar Specification

  • Sensor Type
  • Differential Pressure Sensor
  • Thread
  • 1/8 NPT
  • Seal Material
  • Silicone
  • Display
  • LED Digital Display
  • Grade
  • Industrial
  • Outer Size
  • Approx. 112 x 102 x 48 mm
  • Material
  • Polycarbonate (Enclosure), PCB Electronics
  • Processing Type
  • Electronic
  • Diameter
  • 112 mm
  • Mount Type
  • Wall or Surface Mount
  • Scale Range
  • -12.5 to 12.5 mbar
  • Accuracy
  • 1% of Full Scale
  • Accessories
  • Mounting hardware, user manual
  • Power Supply
  • 12-36 VDC
  • Electrical Connection
  • Screw Terminals
  • Application
  • HVAC, Clean Rooms, Duct Static Pressure
  • Response Time
  • < 1s
  • Protection Level
  • IP65
  • Zero/Span Adjustment
  • Push Button
  • Operating Temperature
  • -10C to +60C
  • Output Signal
  • 4-20 mA, 2-wire
  • Weight
  • Approx. 200 g
  • Model
  • Series DPT10-R8
 

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • FOB Port
  • delhi
  • Payment Terms
  • Cash Against Delivery (CAD), Cash Advance (CA), Cash on Delivery (COD), Cash in Advance (CID)
  • Supply Ability
  • 4 Pieces Per Day
  • Delivery Time
  • 4-6 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Asia, Middle East
  • Main Domestic Market
  • All India
 

About Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar  

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4


Engineered for Precise Differential Pressure Monitoring

With an accuracy of 1% full scale, the DPT10-R8 provides reliable readings for tight control in HVAC systems, clean rooms, and industrial environments. Its fast <1s response time ensures real-time data, vital for sensitive processes. The device measures low-pressure ranges, making it ideal for applications requiring subtle pressure differentials.


Durable and Easy to Install

Housed in a rugged polycarbonate enclosure and sealed with silicone, the transmitter achieves IP65 protection against dust and water. The compact 112 x 102 x 48 mm size, along with included mounting hardware, allows for straightforward wall or surface installation. Connecting the unit is simplified with screw terminals.


Versatile for Multiple Media Applications

Suitable for measuring pressure in steam, oil, and gases, the DPT10-R8 adapts to a broad range of industrial needs. Its 4-20 mA, 2-wire output ensures compatibility with standard process control and monitoring systems, and its broad working voltage range (12-36 VDC) offers flexibility in integration for new or retrofit projects.

FAQ's of Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range -12.5 - 12.5 mbar:


Q: How do I install the Sensocon DPT10-R8 pressure transmitter?

A: The DPT10-R8 is designed for wall or surface mounting. Simply use the included mounting hardware to secure the transmitter in your desired location, then connect the pressure ports (threaded 1/8 NPT) to your process lines. Complete the wiring using the screw terminals according to the user manual.

Q: What is the benefit of using the LED digital display on the DPT10-R8?

A: The LED digital display provides instant, clear readings of the measured differential pressure, allowing for quick monitoring and precise adjustments without the need for external devices, improving both convenience and process control.

Q: Where is the DPT10-R8 most commonly used?

A: This model is ideal for applications like HVAC system monitoring, clean room pressure control, duct static pressure measurement, and detection of differential pressure in steam, oil, or gas pipelines. Its precise measurements are suited for industrial and laboratory environments.

Q: What is the process for adjusting zero and span on this transmitter?

A: Zero and span adjustments can be done easily using the integrated push buttons. This allows the user to quickly calibrate the transmitter onsite for optimal accuracy, as described in the included user manual.

Q: When should I use a differential pressure transmitter in my application?

A: Differential pressure transmitters like the DPT10-R8 are essential when you need to measure low-pressure variations between two points, such as across filters, in air ducts, or for monitoring the pressure drop in various industrial processes to ensure system efficiency and safety.

Q: What output signal does this transmitter provide and how is it powered?

A: The DPT10-R8 outputs a standard 4-20 mA signal using a 2-wire connection. It operates within a power supply range of 12 to 36 VDC, making it compatible with most industrial automation and control systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Differential Pressure Transmitter-Sensocon USA Category

Sensocon USA Series DPT1-R8 - Range 0 - 0.25 in WC

Sensocon USA Series DPT1-R8 - Range 0 - 0.25 in WC

Minimum Order Quantity : 5 Pieces

Seal Material : Integrated EPDM Seals

Thread : N/A (Pressure ports are pushon type for tubing connection)

Scale Range : 0 0.25 in WC

Material : Other, Plastic Enclosure

Sensor Type : Differential Pressure Transmitter

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 12.7 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 12.7 mmWC

Minimum Order Quantity : 5 Pieces

Seal Material : Silicone

Thread : Universal pressure port connections, 1/8 NPT

Scale Range : 0 12.7 mmWC

Material : Other, Glass fiber reinforced polycarbonate housing

Sensor Type : Differential Pressure Transmitter

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25 mbar

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 25 mbar

Minimum Order Quantity : 5 Pieces

Seal Material : Silicone Rubber

Thread : Pushon hose connections, 6 mm ID

Scale Range : 0 25 mbar

Material : Other, Housing: ABS Plastic

Sensor Type : Differential Pressure Sensor

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -127 - 127 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -127 - 127 mmWC

Minimum Order Quantity : 5 Pieces

Seal Material : EPDM

Thread : 1/8 NPT Female

Scale Range : 127 to +127 mmWC

Material : Other, ABS Plastic, Aluminum

Sensor Type : Capacitive Differential Pressure Sensor