Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 250 Pa Specification

  • Grade
  • Industrial
  • Display
  • LED Digital Display
  • Thread
  • 1/8 NPT Female
  • Outer Size
  • 120 mm x 90 mm x 36 mm (Approx.)
  • Sensor Type
  • Differential Pressure Sensor
  • Seal Material
  • Silicone Rubber
  • Material
  • ABS Plastic Body
  • Processing Type
  • Electronics Assembly
  • Mount Type
  • Wall Mount
  • Scale Range
  • 0 - 250 Pa
  • Accuracy
  • 1.5% of Full Scale
  • Accessories
  • Mounting Screws, Manual
  • Power Supply
  • 12-36 VDC
  • Operating Temperature Range
  • -10C to +60C
  • Media Compatibility
  • Dry, Clean and Non-Corrosive Gases
  • Output Signal
  • 4-20 mA (2-wire)
  • Compensated Temperature Range
  • 0C to +50C
  • Model
  • DPT10-R8
  • Protection Class
  • IP54
  • Zero and Span Adjustment
  • Manual via Potentiometer
  • Mounting Orientation
  • Any Position
  • Response Time
  • < 1 s
  • Weight
  • Approx. 170 g
  • Electrical Connection
  • Screw Terminals
 

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 250 Pa Trade Information

  • Minimum Order Quantity
  • 5 Pieces
  • FOB Port
  • delhi
  • Payment Terms
  • Cash Advance (CA), Cash Against Delivery (CAD), Cash on Delivery (COD), Cash in Advance (CID)
  • Supply Ability
  • 4 Pieces Per Day
  • Delivery Time
  • 4-6 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Asia, Middle East
  • Main Domestic Market
  • All India
 

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 250 Pa About

Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 250 Pa

APPLICATIONS 

DPT-R8 series devices are commonly used in HVAC/R systems for: Fan, blower and filter monitoring Pressure and flow monitoring Valve and damper control Pressure monitoring in clean rooms

WARNING 

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS DEVICE.

Failure to observe safety information and comply with instructions could result in PERSONAL INJURY, DEATH AND/ OR PROPERTY DAMAGE.

To avoid electrical shock or damage to equipment, disconnect power before installing or servicing and use only wiring with insulation rated for full device operating voltage.

To avoid potential fire and/or explosion do not use in potentially flammable or explosive atmospheres.

Retain these instructions for future reference.

This product, when installed, will be part of an engineered system whose specifications and performance characteristics are not designed or controlled by Sensocon. Review applications and national and local codes to assure that the installation will be functional and safe. Use only experienced, knowledgeable, technicians to install this device. 

SPECIFICATIONS 

Performance Accuracy (at applied pressure) Ranges < 0.5 inWC = 0.01 inWC Ranges 0.5 inWC = 1.5% inWC Accuracy specifications include: general accuracy, temperature drift, linearity, hysteresis, long term stability, and repetition error

Thermal Effects Temperature compensated across the full spectrum of capability 

 Overpressure Proof Pressure: 100 inWC Burst Pressure: 120 inWC

Zero Point Calibration Automatic with function or Manual push-button Auto-Zero

Response Time 4.0 0.8 sec, Selectable via Jumper

Technical Specifications Media Compatibility Dry air or non-aggressive gases

Measuring Units (select via Jumper) Pa, kPa, mbar, inWC, mmWC Measuring Element Piezoresistive

Environment: Operating Temperature: 14 122F (-10 50C) Storage Temperature: -4 158F (-20 70C) Humidity: 0 to 95 % rH, non condensing 

Physical Case Dimensions: 3.54 x 3.74 x 1.4 (90.0 x 95.0 x 36.0 mm) Weight: 5.3 oz (150 g) Mounting: 2 each 0.1875 (4.3 mm) screw holes, one slotted Materials: Case: ABS (UL 94 V-0 Approved) Lid: PC (UL 94 V-1 Approved) Protection standard: IP54 / NEMA3 

Display (optional) 3 1/2 Digit LCD Backlit Display 2-Line Display (12 character/line) Size: 1.81 W x 0.57 H (46.0 x 14.5 mm) 

Electrical connections: 4 screw terminal block Wire: 12-24AWG (0.2 1.5 mm2 

Cable Entry Strain Relief: M16 Knockout : 0.625 (16mm)

Pressure Fittings 3/16 (5.2mm) barbed brass + High pressure Low pressure 

Electrical Voltage Circuit: 3-wire ([V Out], 24V, GND) Input: 24VAC or VDC, 10% Output: 0-10V or 0-5V, selectable via Jumper Power Consumption: <1.0W Resistance Minimum: 1k

Current Circuit: 3-wire (mA Out, 24V, GND) Input: 24VAC or VDC, 10% Output: 4


Reliable and Versatile Differential Pressure Measurement

The DPT10-R8 Differential Pressure Transmitter offers dependable and precise measurement for steam, oil, and gas applications. With a wide compensated temperature range from 0C to +50C and a robust ABS enclosure, this device is engineered to withstand challenging industrial environments. Easy manual calibration via potentiometer ensures accuracy, while the IP54 rating provides strong protection against dust and minimal water ingress.


Easy Installation and Maintenance

Featuring wall-mount design and screw terminal electrical connections, installation is quick and secure. Weighing approximately 170g, the transmitter includes all necessary mounting accessories for convenient setup. Ongoing maintenance is simplified through accessible manual span and zero adjustments, ensuring sustained high performance and minimal downtime for operators.

FAQ's of Sensocon USA Differential Pressure Transmitter Series DPT10-R8 - Range 0 - 250 Pa:


Q: How is the DPT10-R8 Differential Pressure Transmitter installed?

A: The DPT10-R8 is designed for wall mounting and comes with mounting screws. Electrical connections are made using screw terminals, ensuring a secure and straightforward installation process.

Q: What types of media can the DPT10-R8 measure?

A: This transmitter is compatible with dry, clean, and non-corrosive gases, making it suitable for measuring the pressure of steam, oil, and various gases in industrial environments.

Q: When should zero and span adjustment be performed?

A: Zero and span adjustments are typically performed during initial setup or routine maintenance to ensure the transmitter maintains its 1.5% full scale accuracy. Adjustments are made manually using the potentiometer provided on the device.

Q: Where can the DPT10-R8 be mounted in an industrial setup?

A: It can be mounted in any orientation on a wall, thanks to its flexible design and compact size. This allows for versatile placement to accommodate different spatial requirements within industrial facilities.

Q: What benefits does the 4-20 mA (2-wire) output signal offer?

A: The 4-20 mA (2-wire) output signal is a standard in industrial applications, providing robust long-distance signal transmission with high resistance to electrical noise. This ensures accurate and reliable data integration with process control systems.

Q: How is the transmitter powered, and what voltages are supported?

A: The DPT10-R8 operates on a wide range of DC power supply voltages from 12 to 36 VDC, offering flexibility to adapt to various electrical environments found in industrial applications.

Q: What is the process for verifying device accuracy?

A: Device accuracy, rated at 1.5% of full scale, can be verified during commissioning and periodic maintenance through calibration against a known reference standard and using the manual potentiometer adjustments if needed.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Differential Pressure Transmitter-Sensocon USA Category

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  0 - 2.5 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range 0 - 2.5 mbar

Minimum Order Quantity : 5 Pieces

Processing Type : Other, Microprocessorbased

Scale Range : 0 2.5 mbar

Grade : Industrial

Accuracy : 1% of full scale

Outer Size : 115 x 85 x 35 mm (approx)

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  -127 - 127 mmWC

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range -127 - 127 mmWC

Minimum Order Quantity : 5 Pieces

Processing Type : Other, Electronic

Scale Range : 127 to +127 mmWC

Grade : Industrial

Accuracy : 1.0% of Full Scale

Outer Size : 110 x 87 x 32 mm

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range  0 - 5000 Pa

Sensocon USA Differential Pressure Transmitter Series DPT30-R8 - Range 0 - 5000 Pa

Minimum Order Quantity : 5 Pieces

Processing Type : Other, Electronic

Scale Range : 0 5000 Pa

Grade : Industrial

Accuracy : 1.0% of Full Scale

Outer Size : 115 mm x 90 mm x 55 mm (approx.)

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range  -0.62 - 0.62 mbar

Sensocon USA Differential Pressure Transmitter Series DPT1-R8 - Range -0.62 - 0.62 mbar

Minimum Order Quantity : 5 Pieces

Processing Type : Other, Electronic

Scale Range : 0.62 to +0.62 mbar

Grade : Industrial Grade

Accuracy : 1% FS

Outer Size : Compact Size (specific dimensions see datasheet)