Back to top
Hydraulic Filter for 1800 Concrete Pump
Hydraulic Filter for 1800 Concrete Pump

Hydraulic Filter for 1800 Concrete Pump

Hydraulic Filter for 1800 Concrete Pump Specification

  • Efficiency (%)
  • 99%
  • Capacity
  • Standard for 1800 Concrete Pump hydraulic systems
  • Filter Type
  • Return line filter
  • Filtration Grade
  • Beta 200 (ISO 16889)
  • Media Type
  • Microglass/synthetic filter media
  • Pressure
  • Maximum 16 bar
  • Connecting Type
  • Threaded or flanged end connection
  • Temperature Range
  • -25C to +110C
  • Flow Rate
  • 80-150 L/min
  • Cleaning Method
  • Replaceable cartridge, non-washable
  • Condition
  • New
  • Material
  • High-quality stainless steel and synthetic fibers
  • Mesh
  • Fine filtration mesh (customizable based on requirements)
  • Diameter
  • Approx. 90-100 mm
  • Construction
  • Robust cylindrical cartridge design
  • Medium Filter
  • Hydraulic oil
  • Weight
  • Approx. 1.5 kg
  • Shape
  • Cylinder
  • Feature
  • High filtration efficiency for hydraulic systems, suitable for heavy-duty concrete pumps
 

Hydraulic Filter for 1800 Concrete Pump Trade Information

  • Main Export Market(s)
  • Asia
  • Main Domestic Market
  • All India
 

About Hydraulic Filter for 1800 Concrete Pump

Hydraulic Filter for 1800 Concrete Pump
Our client can avail these Hydraulic Filter at very reasonable price in market. These are manufactured from high grade quality material. Our manufactured industrial hydraulic filter are duly tested by our experts on various quality parameter.
Features:
Excellent performance
Corrosion resistant finish
Long service life
Specifications:

OD-77 MM,Id-43mm,H-327mm

Maximum Protection for Hydraulic Systems

Safeguard your 1800 Concrete Pump with superior filtration efficiency. This hydraulic filter employs a robust stainless steel body and synthetic fiber mesh to trap contaminants, maintaining cleanliness in hydraulic oil. Its dependable NBR gasket and corrosion-resistant metal end cap ensure a tight seal and protection even under intense, heavy-duty conditions.


Exceptional Durability and Compatibility

Built to withstand pressures up to 16 bar and temperatures ranging from -25C to +110C, this filter is designed for exceptional longevity. Developed specifically for 1800 Concrete Pump models, its cylindrical, vertical-mount construction is ideal for both OEM and aftermarket setups, blending seamlessly into existing hydraulic systems.


Efficient Maintenance and Reliable Performance

The filter features a replaceable, non-washable cartridge for straightforward maintenance. With a bypass valve setting of 1.5-2 bar and a flow rate of 80-150 L/min, it guarantees smooth operation of your hydraulic pump. Extend system life and reduce downtime with this high-performing, easy-to-install return line filter.

FAQs of Hydraulic Filter for 1800 Concrete Pump:


Q: How do I install the hydraulic filter on my 1800 Concrete Pump?

A: To install the hydraulic filter, ensure the system is off and depressurized. Mount the filter vertically in the return line using the threaded or flanged end connections, as per the manufacturers specifications for 1800 Concrete Pump models. Check that the NBR gasket seals properly to avoid leaks.

Q: What contaminants does this hydraulic filter remove, and how does it benefit my concrete pump?

A: This filter uses fine synthetic microglass media to trap dirt, debris, and small particles, protecting hydraulic components from abrasive contaminants. High efficiency (99%) filtration prevents premature wear, promoting longer service intervals and improved reliability of your concrete pump.

Q: When should I replace the hydraulic filter for optimal performance?

A: Replace the filter every 2000 operating hours, or sooner if there is a noticeable drop in hydraulic system performance or increased pressure across the filter. Regular replacement ensures continued filtration efficiency and maximum pump protection.

Q: Where is the ideal mounting location for this filter in the hydraulic system?

A: The filter is designed for vertical mounting in the return line of the hydraulic system on 1800 Concrete Pump models. This position enables optimal capture of contaminants from the hydraulic oil returning to the reservoir.

Q: What is the recommended process for changing the cartridge in this hydraulic filter?

A: Turn off and depressurize the system, then unthread or unbolt the old filter cartridge from its housing. Dispose of the used cartridge, clean the mounting area, and install the new cartridge, ensuring the NBR gasket is correctly seated for a leak-free fit.

Q: Can this hydraulic filter be used with other concrete pump models besides the 1800?

A: This filter is specifically designed for 1800 Concrete Pump models. For other models, check compatibility with system dimensions, flow rate, and connection types or consult with the manufacturer or supplier before installation.

Q: What are the primary benefits of using a high-quality hydraulic filter in concrete pump applications?

A: A premium hydraulic filter extends large equipment service life, reduces maintenance downtime, and ensures reliable pump operation by efficiently protecting hydraulic components from contaminantseven in demanding conditions faced by heavy-duty concrete pumps.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gas Turbine Air Intake Filters Category

Mixer Hydraulic Filter

Mixer Hydraulic Filter

Shape : Cylindrical

Filtration Grade : Other, Fine filtration

Construction : Other, Cartridge, Pleated design

Filter Type : Hydraulic Filter

Media Type : Other, Synthetic Fiber/Cellulose

Capacity : Varies as per model

Hydraulic Oil Filter For 350 Concrete Pump

Hydraulic Oil Filter For 350 Concrete Pump

Shape : Cylindrical

Filtration Grade : Other, Fine Filtration, Industrial Grade

Construction : Other, Cartridge Type, End Cap Sealed

Filter Type : Hydraulic Oil Filter

Media Type : Other, Glass Fiber/Cellulose/Stainless Steel Mesh

Capacity : Large Capacity for continuous operation

Heavy Duty Air Filter

Heavy Duty Air Filter

Shape : Cylindrical

Filtration Grade : Other, Industrial Grade

Construction : Other, Heavy Duty, Rugged Metal Frame

Filter Type : Cartridge / Panel Type

Media Type : Other, Synthetic Nonwoven / Pleated

Capacity : High Dust Holding Capacity (up to 10kg dust)

Hydraulic Suction Filter

Hydraulic Suction Filter

Shape : Cylindrical

Filtration Grade : Other, Pre Filter

Construction : Other, Round cylindrical body with threaded end cap

Filter Type : Suction Filter

Media Type : Other, Liquid

Capacity : Customizable