About GEMTECH Differential Pressure Gauges wholesale - Chennai Tamil Nadu
GEMTECH Differential Pressure Gauges wholesale - Chennai Tamil Nadu
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System.Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment.There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION - Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 (21 (3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)

FEATURES - OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS - Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERINGGEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model | Description |
| G2000-100MM | DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM | DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM | DPG,Range 0-150 MM W.C. |
| G2000-15MM | DPG,Range 0-15 MM W.C. |
| G2000-200MM | DPG,Range 0-200 MM W.C. |
| G2000-250MM | DPG,Range 0-250 MM W.C. |
| G2000-25MM | DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM | DPG,Range 0-300 MM W.C. |
| G2000-50MM | DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM | DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM | DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
Reliable Pressure Monitoring for Industrial ApplicationsGEMTECH Differential Pressure Gauges are engineered for diverse industries, offering precise measurement of steam, oil, and gas pressures. The gauge is designed for environments where accuracy and durability are vital, suitable for plants, hospitals, hotels, and industrial manufacturing.
Versatile and Durable DesignWith its stainless steel construction, a robust 4-inch diameter, and premium finishes, the GEMTECH gauge is built to withstand the rigors of industrial usage. The dial's plastic material and aluminum pointer ensure clear visibility and long-term operational reliability.
FAQ's of GEMTECH Differential Pressure Gauges wholesale - Chennai Tamil Nadu:
Q: How does the GEMTECH Differential Pressure Gauge work in various industrial settings?
A: The GEMTECH Differential Pressure Gauge measures pressure differences accurately in systems handling steam, oil, or gas. It uses a precise analog mechanism, making it suitable for pharmaceutical manufacturing, power plants, hospitals, textiles, and more.
Q: What pressure measurement ranges are available with this gauge?
A: The gauge supports multiple scale ranges, including MM WC, CM, PAC, KPA, and INCH, providing flexibility for various measurement requirements in industrial processes.
Q: When should these gauges be installed in a facility?
A: GEMTECH Differential Pressure Gauges should be installed during equipment commissioning, routine maintenance, or system upgrades where monitoring of pressure differentials is crucial for safety and operational efficiency.
Q: Where can the GEMTECH Differential Pressure Gauge be mounted?
A: This model features a back mount, making it ideal for panel installations or where space constraints exist. Its compact, lightweight design allows it to fit seamlessly into new and existing setups.
Q: What is the process of calibrating the GEMTECH Differential Pressure Gauge?
A: Calibration involves comparing the gauge's readings with a reference standard under controlled conditions, adjusting as necessary. It is recommended to calibrate annually or based on regulatory requirements to maintain accuracy.
Q: How can this gauge benefit industries like hospitals and manufacturing?
A: By providing precise and reliable pressure monitoring, the GEMTECH Differential Pressure Gauge helps maintain safe conditions, prevent equipment failures, and improve process efficiency in sensitive environments such as hospitals, power plants, and industrial manufacturing.