About GEMTECH Differential Pressure Gauges Supplier by Moradabad Uttar Pradesh
GEMTECH Differential Pressure Gauges Supplier by Moradabad Uttar Pradesh
Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine,resistance of Filter, Wind Speed, Furnace Pressure,Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System.Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel,with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 (21 (3% on -0,and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)
FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa

PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERING
GEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model | Description |
| G2000-100MM | DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM | DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM | DPG,Range 0-150 MM W.C. |
| G2000-15MM | DPG,Range 0-15 MM W.C. |
| G2000-200MM | DPG,Range 0-200 MM W.C. |
| G2000-250MM | DPG,Range 0-250 MM W.C. |
| G2000-25MM | DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM | DPG,Range 0-300 MM W.C. |
| G2000-50MM | DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM | DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM | DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
Versatility Across IndustriesEngineered to meet the rigorous demands of various sectors, including pharmaceuticals, hospitals, power plants, and manufacturing, the GEMTECH Differential Pressure Gauge delivers reliable measurements in critical operations. Its flexible mounting and robust build suit diverse installation environments, from OT rooms to steel and cement plants.
Precision and DurabilityThis gauge provides 2% accuracy of full span at optimal temperatures, ensuring dependable readings where precision is critical. Constructed from top-grade materials such as metal alloy and fitted with a protective plastic dial, it stands up to challenging industrial conditions. Multiple finishing options enhance durability and appearance.
Comprehensive Measurement CapabilitiesDesigned to measure the pressure of steam, oil, and gas, this device covers a wide scale range including MM WC, CM, PAC, KPA, INCH, and PSI. Its analog display ensures easy reading, while the 100 mm dial offers visibility from a distance, making it a valuable asset for continuous monitoring.
FAQ's of GEMTECH Differential Pressure Gauges Supplier by Moradabad Uttar Pradesh:
Q: How is the GEMTECH Differential Pressure Gauge installed and mounted?
A: The gauge is designed with a back mount configuration, making it suitable for panel or equipment mounting. Installation should be performed by a trained technician in accordance with site requirements for safety and optimal performance.
Q: What pressure media can be measured with this gauge?
A: This differential pressure gauge can measure the pressure of steam, oil, and gas, which makes it highly versatile for use in a wide range of applications within industrial, commercial, and institutional settings.
Q: When is it necessary to calibrate the GEMTECH Differential Pressure Gauge?
A: Calibration is recommended annually, or more frequently in critical applications, to ensure continued measurement accuracy. Calibration intervals can be adjusted based on the site usage conditions and adherence to industry standards.
Q: Where is this differential pressure gauge primarily used?
A: The gauge is widely used in pharmaceuticals, hospitals, hotels, malls, power plants, cement and steel plants, fertilizer and textile industries, food and beverage processing, and paper production due to its reliability and performance.
Q: What are the key benefits of using this gauge in industrial applications?
A: It provides precise pressure monitoring, critical for process safety and efficiency. The durable metal alloy construction and finishing options resist corrosion, while its compatibility with various scale ranges ensures adaptability to multiple system requirements.
Q: How should users interpret the analog display and scale markings?
A: The analog display is marked in MM WC, CM, PAC, KPA, INCH, and PSI, allowing users to obtain readings in their preferred units. The aluminum pointer ensures easy visibility and quick assessment of system pressure levels.
Q: What is the recommended process for handling and maintaining this gauge?
A: Routine inspection for mechanical integrity and cleanliness of the dial face is recommended. Avoid exposure to corrosive chemicals and ensure periodic recalibration for accurate readings. Handle the gauge carefully during installation to prevent damage to the pointer and dial.