Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70 (21 (3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)

FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERINGGEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model |
Description |
| G2000-100MM |
DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
DPG,Range 0-150 MM W.C. |
| G2000-15MM |
DPG,Range 0-15 MM W.C. |
| G2000-200MM |
DPG,Range 0-200 MM W.C. |
| G2000-250MM |
DPG,Range 0-250 MM W.C. |
| G2000-25MM |
DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
DPG,Range 0-300 MM W.C. |
| G2000-50MM |
DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
Versatile Application Across IndustriesGEMTECH Differential Pressure Gauge proves ideal for demanding environments-pharmaceutical production, power and cement plants, malls, hospitals, and more. Its ability to measure pressure in steam, oil, and gas systems ensures precise monitoring and safe system operations, catering to versatile industry needs.
Precision Engineering and DurabilityFeaturing stainless steel construction and a robust plastic dial, the gauge delivers consistent accuracy with an error margin as narrow as 2%. The back-mount design, paired with a variety of finishes, ensures longevity, resistance to corrosive conditions, and an appealing aesthetic.
FAQ's of GEMTECH Differential Pressure Gauge Dealers Pune:
Q: How does the GEMTECH Differential Pressure Gauge operate?
A: The gauge operates by measuring the difference in pressure between two points in steam, oil, or gas systems, providing clear readings through its analog display for monitoring and process control.
Q: What are the main industries where this pressure gauge can be used?
A: It is suitable for use in pharmaceutical manufacturing, hospitals, hotels, malls, power plants, cement, steel, fertilizer, textile, pulp and paper, and the food and beverage industries.
Q: When should I calibrate the GEMTECH Differential Pressure Gauge?
A: Regular calibration is recommended according to industry standards or whenever you observe inconsistent readings, ensuring measurement accuracy and optimal system performance.
Q: Where should the pressure gauge be installed for best performance?
A: The gauge is designed for back mount installation, typically positioned where differential pressure needs to be monitored between two points, such as across filters, pumps, or pipelines.
Q: What is the benefit of choosing a stainless steel body for this gauge?
A: A stainless steel body enhances durability, offers excellent corrosion resistance, and ensures the gauge withstands harsh industrial environments for extended service life.
Q: How precise are the readings from the GEMTECH Differential Pressure Gauge?
A: The gauge provides high accuracy with an error margin of 2% of full scale at standard conditions (70 (21) C), ensuring reliable readings for sensitive applications.