About DWYER 2003D Magnehelic Differential Pressure Gauge From Sindhuvalli Bus Stop Nanjangud Karnataka India
DWYER 2003D Magnehelic Differential Pressure Gauge From Sindhuvalli Bus Stop Nanjangud Karnataka India
- Dwyer 2000-3D Magnehelic Differential Pressure Gauge (0-3.0"w.c. & 0-750 Pa)
- Model: 2000-3D
Dual scale. Bezel Provides Flange For Flush Mounting in Panel. Clear Plastic Face is Highly Resistant To Breakage. Provides Undistorted Viewing of Pointer And Scale.
DESCRIPTION
Dwyer 2000-3D OffersFeatures
- Measures Fan and Blower Pressures, Filter Resistance, Air Velocity, Furnace Draft, Pressure Drop Across Orifice Plates
- Measures Liquid Levels With Bubbler Systems and Pressures in Fluid Amplifier Or Fluidic Systems
- Checks Gas-Air Ratio Controls and Automatic Valves
- Monitors Blood and Respiratory Pressures in Medical Care Equipment
Specifications
Dwyer 2000-3D Specifications
| Range, in w.c. |
0-3.0"w.c. |
| Range, Pa or kPa |
0-750 Pa |
| Service |
Air And Non-Combustible, Compatible Gases |
| Housing |
Die Cast Aluminum Case And Bezel, With Acrylic Cover. Exterior Finish is Coated Gray to Withstand 168 Hour Salt Spray Corrosion Test. |
| Accuracy |
A2% of FS (A3% on 0, -100 Pa, -125 Pa, 10MM and A4% on a 00, -60 Pa, -6MM ranges), throughout range at 70AF (21.1AC) |
| Pressure Limits |
-20 in Hg to 15 psiga (-0.677 to 1.034 bar) MP Option: 35 psig (2.41 bar) HP Option: 80 psig (5.52 bar) |
| Overpressure |
Relief Plug Opens at Approximately 25 psig (1.72 bar), standard gauges only |
| Temperature Limits |
20 to 140AF (-6.67 to 60AC) -20AF (-28AC) with low temperature option |
| Size |
4a3 (101.6 mm) Diameter Dial Face |
| Mounting Orientation |
Diaphragm in vertical position |
| Process Connections |
1/8a3 Female NPT duplicate high and low pressure taps a one pair side and one pair back |
| Weight |
1 lb 2 oz (510 g) MP & HP 2 lb 2 oz (963 g) |
| Agency Approval |
RoHS |
Click Here For Complete Specifications On The Dwyer 2000-3D
Included
- Whatas Included With The Dwyer 2000-3D
- Dwyer 2000-3D Magnehelic
Reliable Performance for Critical Applications
Engineered for use in diverse industries, the DWYER 2003D Magnehelic Differential Pressure Gauge offers robust performance in pharmaceutical manufacturing, power and cement plants, food and beverage sectors, textiles, and more. Its precision and durable design make it ideal for environments where accurate differential pressure measurement is essential.
Versatile Construction and Aesthetic Choices
Combining function with choice, this gauge is available in a striking black color with multiple finishing options-antique, polished, galvanized, or matte. Its stainless steel construction and 4-inch analog dial enhance durability and readability, while refined finishes ensure compatibility with various facility aesthetics.
Easy Installation and Wide Compatibility
With a back mount design and lightweight construction (510 grams), installation is straightforward in a wide array of settings, including hospitals, malls, and industrial plants. Engineered as per standard processing guidelines, the gauge supports seamless integration into both new and existing systems.
FAQ's of DWYER 2003D Magnehelic Differential Pressure Gauge From Sindhuvalli Bus Stop Nanjangud Karnataka India:
Q: How does the DWYER 2003D Magnehelic Differential Pressure Gauge operate?
A: This pressure gauge works by measuring the difference in pressure between two points-ideal for monitoring low pressure of steam, oil, and gas. The analog dial displays real-time data, allowing for quick and accurate readings even in challenging environments.
Q: What types of environments and industries is the gauge suitable for?
A: The DWYER 2003D is engineered for use in pharmaceutical manufacturing, hospitals (OT), hotels, malls, power plants, cement plants, textile and steel plants, fertilizer production, food and beverage industries, and pulp and paper facilities. Its durability and precision make it adaptable to a range of professional applications.
Q: When should the gauge be calibrated or maintained?
A: Regular calibration is recommended as part of routine maintenance schedules, especially in high-precision environments like pharmaceuticals and laboratories. Checking calibration annually or as required by facility standards ensures reliable and accurate readings.
Q: Where should the DWYER 2003D gauge be installed for optimal performance?
A: The gauge is designed for back mount installation, making it suitable for mounting on walls or panels in control rooms or onsite near the point of pressure measurement. Proper installation ensures the most accurate readings and protects the gauge from mechanical damage.
Q: What is the measuring range and accuracy of the gauge?
A: The DWYER 2003D offers scale ranges from 0-3.0" w.c. (water column) and 0-750 Pa (Pascal). It guarantees an accuracy of 2% of the full scale (with slightly different tolerances on certain ranges), ensuring dependable monitoring even at lower and higher ends of the spectrum.
Q: How can using this pressure gauge benefit industrial processes?
A: Utilizing the DWYER 2003D can enhance system reliability, improve safety, and support regulatory compliance by providing precise differential pressure measurements. Its clear analog display and durable construction facilitate quick decision-making and minimize downtime in various industries.
Q: What materials are used in the construction, and why are they important?
A: Constructed with a stainless steel body, plastic dial, and an aluminum pointer, the gauge is resistant to corrosion and wear, ensuring longevity-even in demanding and corrosive environments common in industrial applications.