Dwyer 2000-00N Magnehelic Gage Range .05-0-.20 Inch WC
Dwyer 2000-00N Magnehelic Gage Range .05-0-.20 Inch WC
Dwyer 2000-00N Magnehelic Gage Range .05-0-.20 Inch WC
Dwyer 2000-00N Magnehelic Gage Range .05-0-.20 Inch WC

Dwyer 2000-00N Magnehelic Gage Range .05-0-.20 Inch WC

MOQ : 10 Pieces

Dwyer 2000-00N Magnehelic Gage Range .05-0-.20 Inch WC Specification

  • Outer Size
  • 4 inch (101 mm) diameter
  • Grade
  • Industrial
  • Thread
  • 1/8 NPT
  • Sensor Type
  • Differential Pressure
  • Display
  • Analog
  • Seal Material
  • Silicone rubber diaphragm
  • Material
  • Die cast aluminum housing
  • Dial Material
  • White with black markings
  • Pointer Material
  • Red tipped aluminum
  • Processing Type
  • Precision molded
  • Diameter
  • 4 inch (101 mm)
  • Glass Size
  • Clear acrylic cover
  • Mount Type
  • Surface or flush mounting
  • Scale Range
  • 0.05-0-0.20 Inch WC
  • Accuracy
  • 2% FS
  • Finishing
  • Molded plastic housing, clear acrylic cover
  • Measure Pressure Of
  • Low differential pressure of air and non-corrosive gases
  • Accessories
  • Two 1/8 NPT plugs, two 1/8 rubber tubing adapters, three mounting adapters & screws, instruction sheet
 

Dwyer 2000-00N Magnehelic Gage Range .05-0-.20 Inch WC Trade Information

  • Minimum Order Quantity
  • 10 Pieces
  • Payment Terms
  • Cash on Delivery (COD), Cash Against Delivery (CAD), Cash Advance (CA), Cash in Advance (CID)
  • Main Export Market(s)
  • Middle East, Asia
  • Main Domestic Market
  • South India, Central India, North India, East India, West India, Andhra Pradesh, Assam, Bihar, Chhattisgarh, Chandigarh, Delhi, Gujarat, Goa, Haryana, Himachal Pradesh, Jharkhand, Karnataka, Kerala, Madhya Pradesh, Mizoram, Nagaland, Odisha, Punjab, Rajasthan, Tamil Nadu, Telangana, Uttar Pradesh, West Bengal, Jammu and Kashmir, Manipur, Sikkim, Tripura, Meghalaya, Arunachal Pradesh, Andaman and Nicobar Islands, Pondicherry, Daman and Diu, Uttarakhand, Dadra and Nagar Haveli, Lakshadweep, Maharashtra, All India
 

About Dwyer 2000-00N Magnehelic Gage Range .05-0-.20 Inch WC

Dwyer 2000-00N Magnehelic Gage Range .05-0-.20 Inch WC

Magnehelic Gage is the industry standard to measure fan and Blower Pressures, Filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment. Bezel provides flange for flush mounting in panel. Clear plastic face is highly resistant to breakage. Provides undistorted viewing of pointer and scale. Precision litho-printed scale is accurate and easy to read. Red tipped pointer of heat treated aluminum tubing is easy to see. It is rigidly mounted on the helix shaft. Pointer stops of molded rubber prevent pointer over-travel without damage. "Wishbone" assembly provides mounting for helix, helix bearings and pointer shaft. Jeweled bearings are shock-resistant mounted; provide virtually friction-free motion for helix. Motion damped with high viscosity silicone fluid. Zero adjustment screw is conveniently located in the plastic cover, and is accessible without removing the cover. O-ring seal provides pressure tightness. Helix is precision made from an alloy of high magnetic permeability. Mounted in jeweled bearings, it turns freely, following the magnetic field to move the pointer across the scale. Calibrated range spring is flat spring steel. Small amplitude of motion assures consistency and long life. It reacts to pressure on diaphragm. Live length adjustable for calibration. Silicone rubber diaphragm with integrally molded O-ring is supported by front and rear plates. It is locked and sealed in position with a sealing plate and retaining ring. Diaphragm motion is restricted to prevent damage due to overpressures. Die cast aluminum case is precision made and iridite-dipped to withstand 168 hour salt spray corrosion test. Exterior finished in baked dark gray hammerloid. One case size is used for all standard pressure options, and for both surface and flush mounting. OVERPRESSURE PROTECTION Blowout plug is comprised of a rubber plug on the rear which functions as a relief valve by unseating and venting the Gage interior when over pressure reaches approximately 25 psig (1.7 bar). To provide a free path for pressure relief, there are four spacer pads which maintain 0.023" clearance when gage is surface mounted. Do not obstruct the gap created by these pads. The blowout plug is not used on models above 180" of water pressure, medium or high pressure models, or on Gages which require an elastomer other than silicone for the diaphragm. The blowout plug should not be used as a system overpressure control. High supply pressures may still cause the gage to fail due to over pressurization, resulting in property damage or serious injury. Good engineering practices should be utilized to prevent your system from exceeding the ratings or any component. O-ring seal for cover assures pressure integrity of case. Samarium Cobalt magnet mounted at one end of range spring rotates helix without mechanical linkages.



Precision Differential Pressure Measurement

Featuring a low-range scale of 0.05-0-0.20 Inch WC, the 2000-00N Magnehelic Gage provides precise monitoring of differential pressure in HVAC systems, clean rooms, and industrial processes. The sensitive silicone rubber diaphragm ensures accurate and responsive readings, supported by a 2% full scale accuracy. The analog display, red-tipped pointer, and clear contrast dial further enhance visibility and reliability for technicians.


Rugged and Versatile Design

Housed in precision-molded die-cast aluminum with a clear acrylic cover, the 2000-00N offers durability in demanding environments. Its dual connection ports and multiple mounting options allow surface or flush installations, making it adaptable for various setups. The gauge is lightweight and supplied with all needed accessories, including tubing adapters and mounting hardware for easy setup.


User-Friendly Operation and Maintenance

Zero point adjustments can be made easily using the external front adjustment screw, minimizing downtime. The instruction sheet guides users through installation and calibration, ensuring smooth operation day-in, day-out. This gages broad operating temperature range and robust sealing allow it to function reliably in diverse conditions encountered in industrial and laboratory settings.

FAQs of Dwyer 2000-00N Magnehelic Gage Range .05-0-.20 Inch WC:


Q: How is the Dwyer 2000-00N Magnehelic Gage installed and what accessories are included?

A: The 2000-00N can be surface or flush mounted using the included mounting adapters and screws. It is supplied with two 1/8 NPT plugs, two 1/8 rubber tubing adapters, and a comprehensive instruction sheet to facilitate installation. Side and back connections provide flexibility for system integration.

Q: What applications are suited for this Magnehelic Gage and how does it benefit users?

A: This gauge excels in HVAC systems, clean rooms, filter monitoring, and fan or blower pressure measurement. It ensures process control and equipment efficiency by providing accurate, real-time differential pressure readings for air and non-corrosive gases, reducing maintenance requirements and potential downtime.

Q: When should the zero adjustment be performed and how is it done?

A: Its recommended to check and adjust the zero point during installation and periodically thereafter. The front external adjustment screw makes zeroing convenient without disassembling the unit, maintaining measurement accuracy across its lifespan.

Q: Where can the Magnehelic Gage be mounted and what connection types does it support?

A: It supports both surface and flush mounting for versatile installation in equipment panels or walls. The unit features 1/8 NPT side and back connection ports, allowing easy integration with standard piping and tubing systems.

Q: What is the maximum operating pressure and temperature range of this device?

A: The 2000-00N can handle up to 25 psig (1.7 bar) and operates reliably in temperatures ranging from 20 to 140F (-6.67 to 60C), making it suitable for a range of industrial and laboratory environments.

Q: How does the analog display aid in measurement?

A: The gauge features a white dial with clear black markings and a red-tipped aluminum pointer under a clear acrylic cover. This setup ensures quick, accurate reading of low differential pressures for process control or maintenance checks.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sensocon - Dwyer S2000 Pressure Gauge Category

Dwyer 2000-750PA Magnehelic Differential Pressure Gauge

Dwyer 2000-750PA Magnehelic Differential Pressure Gauge

Price 4500 INR

Minimum Order Quantity : 5 Pieces

Measure Pressure Of : Other, Air and Noncorrosive Gases

Glass Size : Full view (approx. 101.6 mm OD)

Scale Range : 0750 Pa

Mount Type : Other, Surface or Flush Mount

Dwyer USA Model 2300-00 Magnehelic Gage Range 0.125-0-0.125 Inch WC

Dwyer USA Model 2300-00 Magnehelic Gage Range 0.125-0-0.125 Inch WC

Minimum Order Quantity : 10 Pieces

Measure Pressure Of : Other, Air and compatible gases

Glass Size : 35/16 (84.1 mm)

Scale Range : 0.12500.125 Inch WC (Water Column)

Mount Type : Other, Surface or flush mount

Dwyer 2000-200CM Magnehelic Differential Pressure Gauge

Dwyer 2000-200CM Magnehelic Differential Pressure Gauge

Minimum Order Quantity : 10 Pieces

Measure Pressure Of : Steam, Oil, Gas

Dwyer USA Magnehelic Gauges 0 To 150 MM WC

Dwyer USA Magnehelic Gauges 0 To 150 MM WC

Price 4500 INR

Minimum Order Quantity : 5 Pieces

Measure Pressure Of : Steam, Gas, Oil