Series G2000 GEMTECH Differential Pressure Gauges are Widely Utilized For Measuring Pressure of Fan And Blowing Machine, resistance of Filter, Wind Speed, Furnace Pressure, Differential Pressure Of Pore Plate,The Pressure of drum water level, Liquid Amplifier And Hydraulic Pressure System. Meantime,They Are Used To Control The Automatic Valve And Specific Value Of Air-Producer Gas In Combustion And They Are Used To Test Blood Pressure And Respiratory Pressure In Medical Health Care Equipment. There Are More Than 81 Models To Suit Your Needs Precisely.The Key Components Adopt Import Materials.
SPECIFICATION
- Ambient Temperature - -21 140 -6 60
- Rated Pressure -20 inHg30 inHg (-68103KPa)
- Overpressure - Protective rubber stopper will be blown out if rated pressure is up to about 50.8 inHg (172KPa)
- Process Connections - 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back
- Housing - Die cast aluminum case and bezel, with acrylic cover, Exterior finish is coated gray to withstand 168 Hour Salt Spray Corrosion Test
- Accuracy - 2% of full span at 70(21(3% on -0, and 4% on -00)
- Range -20 inHg38 inHg (-68KPa130KPa)(Special Specification also can be ordered.)

FEATURES
- OEM/ODM
- There Is No Need To Fill Liquid To Gauge.
- The Gauge Can Measure Positive Pressure,Negative Pressure And Differential Pressure.
- It Will Be Easy To Install And Measure In Different Ways Because Of Two Groups Of Ports Which Can Measure Positive And Negative Pressure.
- To Eliminate The Friction From The Movement Of Gear Wheel By The Mechanism Of Magnetic Magnet Feed.
- Exact And Stable Fixed Position Of Needle.
- The Gauge Has Great Antiknock Characteristics.
- There Are 81 Types Of Ranges.Minimum is 0-60 Pa And Maximum is 0-21-KPa
PRODUCT APPLICATIONS
- Filter Monitoring
- Air Velocity With Pitot Tube
- Blower Vacuum Monitoring
- Fan Pressure Indication
- Duct,Room or Building Pressures
- Clean Room Positive Pressure Indication
MODELS & ORDERINGGEMTECH By Model Number Popularity
- FILTER BY
- Range - MM Of Water
| Model |
Description |
| G2000-100MM |
DPG,Range 0-100 MM W.C., Minor Divisions 2.0. |
| G2000-10MM |
DPG,Range 0-10 MM W.C.,Minor Divisions .20,Calibrated For Vertical Scale Position. |
| G2000-150MM |
DPG,Range 0-150 MM W.C. |
| G2000-15MM |
DPG,Range 0-15 MM W.C. |
| G2000-200MM |
DPG,Range 0-200 MM W.C. |
| G2000-250MM |
DPG,Range 0-250 MM W.C. |
| G2000-25MM |
DPG,Range 0-25 MM W.C. Minor Divisions .50. |
| G2000-300MM |
DPG,Range 0-300 MM W.C. |
| G2000-50MM |
DPG,Range 0-50 MM W.C., Minor Divisions 1.0. |
| G2000-6MM |
DPG,Range 0-6 MM W.C., Minor Divisions .20, Calibrated For Vertical Scale Position. |
| G2000-80MM |
DPG,Range 0-80 MM W.C., Minor Divisions 2.0. |
Precision Measurement Across IndustriesGEMTECH Differential Pressure Gauges are engineered for consistent, accurate readings in critical environments, including power, cement, steel, and fertilizer plants, as well as hotels and hospitals. Their robust stainless steel construction and versatile scale range make them indispensable for both heavy-duty and precise monitoring tasks.
Advanced Design for Reliable OperationWith a 4-inch (100 mm) analog display, back mount installation, and a lightweight 550-gram build, these gauges provide effortless use and long-lasting performance. The combination of a plastic dial, aluminum pointer, and diverse finishes-from antique to matte-ensures both readability and resilience in demanding settings.
FAQ's of GEMTECH Differential Pressure Gauges Distributors by Kapurthala Punjab:
Q: How are GEMTECH Differential Pressure Gauges installed and mounted?
A: These gauges feature a back mount design, allowing secure and straightforward installation onto panels or equipment surfaces. Their compact 4-inch diameter makes them suitable for a variety of industrial and commercial environments.
Q: What substances can GEMTECH Differential Pressure Gauges measure?
A: GEMTECH gauges are designed to measure differential pressure in steam, oil, and gas, making them highly adaptable for use in sectors such as pharmaceuticals, food and beverage, power plants, and more.
Q: When should I use a differential pressure gauge in my facility?
A: Deploy these gauges when you need to monitor critical pressure differences, such as across filters, pumps, or pipelines. Accurate differential readings are vital for maintaining operational safety and efficiency.
Q: Where are GEMTECH Differential Pressure Gauges commonly used?
A: These gauges are utilized in a variety of settings, including pharmaceutical manufacturing, hospitals, hotels, malls, and numerous industrial plants-including those in power, cement, textile, and steel sectors.
Q: What is the accuracy of these differential pressure gauges?
A: GEMTECH Differential Pressure Gauges offer an accuracy of 2% of full span at 21C, ensuring reliable and precise pressure readings essential for quality and safety assurance.
Q: How does the gauge's material and finish benefit users?
A: Constructed from stainless steel with finishes like antique, polished, galvanized, or matte, these gauges resist corrosion and wear, providing longevity even in harsh industrial environments.
Q: What are the benefits of using a GEMTECH Differential Pressure Gauge?
A: Benefits include enhanced process control, early detection of system issues, improved safety, and reduced maintenance costs-all achieved through accurate, real-time analog readings.